Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A novel 3D technique to assess symmetry of hemi pelvises

View through CrossRef
AbstractAnatomical reconstruction of pelvic fractures has been shown to affect functional outcome. Using the contra lateral side of the extremities to create a template for an ipsilateral reconstruction is common practice in orthopedic surgery. We aimed to assess whether hemi pelvises are symmetrical in terms of translation and rotation using 3D reconstruction, point to point mirroring and merging of the 3D created volumes, a method with previous proven high precision and accuracy. CT images of ten randomly selected patients were used. The DICOM images were converted to STL files. Three dimensional images of left hemi pelvis were reversed and merged with the right side. The posterior aspect of the pelvises was considered static and the anterior aspect as moving. Differences in translation and rotation were measured. There were no statistically significant differences between right and left hemi pelvis. The 95% confidence interval (CI) for all mean angular differences between right hemi pelvis and mirrored left hemi pelvis were − 2° to 1.5°. The 95% CI for all mean translational differences between these two objects were − 2.3 to 2.9 mm. Differences between the right hemi pelvis and the mirrored images of the left hemi pelvis for any patient greater than 3 mm or 2 degrees could be excluded with a 95% confidence. The left and right hemi pelvis of healthy adults are symmetrical enough. The pre-operative planning based on a healthy contra lateral side seems reasonable.
Title: A novel 3D technique to assess symmetry of hemi pelvises
Description:
AbstractAnatomical reconstruction of pelvic fractures has been shown to affect functional outcome.
Using the contra lateral side of the extremities to create a template for an ipsilateral reconstruction is common practice in orthopedic surgery.
We aimed to assess whether hemi pelvises are symmetrical in terms of translation and rotation using 3D reconstruction, point to point mirroring and merging of the 3D created volumes, a method with previous proven high precision and accuracy.
CT images of ten randomly selected patients were used.
The DICOM images were converted to STL files.
Three dimensional images of left hemi pelvis were reversed and merged with the right side.
The posterior aspect of the pelvises was considered static and the anterior aspect as moving.
Differences in translation and rotation were measured.
There were no statistically significant differences between right and left hemi pelvis.
The 95% confidence interval (CI) for all mean angular differences between right hemi pelvis and mirrored left hemi pelvis were − 2° to 1.
5°.
The 95% CI for all mean translational differences between these two objects were − 2.
3 to 2.
9 mm.
Differences between the right hemi pelvis and the mirrored images of the left hemi pelvis for any patient greater than 3 mm or 2 degrees could be excluded with a 95% confidence.
The left and right hemi pelvis of healthy adults are symmetrical enough.
The pre-operative planning based on a healthy contra lateral side seems reasonable.

Related Results

FREQUENCY OF POSTOPERATIVE COMPLICATION IN PATIENT UNDERGOING HEMI-THYROIDECTOMY WITH AND WITHOUT DRAIN
FREQUENCY OF POSTOPERATIVE COMPLICATION IN PATIENT UNDERGOING HEMI-THYROIDECTOMY WITH AND WITHOUT DRAIN
Introduction: After thyroid surgery, the need for drain placement has become a contentious topic. Drains are frequently utilized to prevent problems and help in the early detection...
Fundamental Symmetries and Symmetry Violations from High Resolution Spectroscopy
Fundamental Symmetries and Symmetry Violations from High Resolution Spectroscopy
AbstractAfter an introductory survey, we introduce the seven fundamental symmetries of physics in relation to the group of the molecular Hamiltonian and the current standard model ...
Automated Symmetry Exploitation in Engineering Analysis
Automated Symmetry Exploitation in Engineering Analysis
It is well known that one can exploit symmetry to speed-up engineering analysis and improve accuracy, at the same time. Not surprisingly, most CAE systems have standard ‘provisions...
Brain Activity in Response to Visual Symmetry
Brain Activity in Response to Visual Symmetry
A number of studies have explored visual symmetry processing by measuring event related potentials and neural oscillatory activity. There is a sustained posterior negativity (SPN) ...
A Framework for Detection of Exact Global and Partial Symmetry in 3D CAD Models
A Framework for Detection of Exact Global and Partial Symmetry in 3D CAD Models
The most common way to retrieve symmetry information (i.e., the planes and axes of symmetry) in 3D CAD models is through visual recognition by engineers. However, engineers are not...
Bilateral Symmetry of Jumping and Agility in Professional Basketball Players: Differentiating Performance Levels and Playing Positions
Bilateral Symmetry of Jumping and Agility in Professional Basketball Players: Differentiating Performance Levels and Playing Positions
Although functional asymmetry is very common and normal in professional athletes, the better interlimb symmetry between dominant and nondominant sides (bilateral symmetry) could co...
Symmetry and symmetry breaking in science and arts
Symmetry and symmetry breaking in science and arts
In this review article, symmetry and symmetry breaking are considered as complementary principles in science and arts. It starts with symmetry and symmetry breaking in early world ...

Back to Top