Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Enhancement of Oily Wastewater Treatment by Ceramic Microfiltration Membranes using Powder Activated Carbon

View through CrossRef
AbstractResults of a hybrid microfiltration‐powdered activated carbon (MF‐PAC) system for the treatment of synthetic oily wastewaters with mullite and mullite‐alumina (50 % alumina content) ceramic membranes are presented. The experiments were conducted to determine the effects of the presence of PAC on MF process performance in terms of flux decline, membrane fouling, and total organic carbon (TOC) rejection. The experimental results demonstrate that PAC addition at low concentration (200–400 ppm) increases permeate flux by 19.6 % for mullite and 61 % for mullite‐alumina MF membranes. However, high PAC concentration (1200 ppm) decreases the permeate flux by 22 % for mullite and 25 % for mullite‐alumina MF membranes. Also, TOC rejection increases from 93.8 to 97.4 % for mullite and from 89.6 to 92.4 % for mullite‐alumina MF membranes.
Title: Enhancement of Oily Wastewater Treatment by Ceramic Microfiltration Membranes using Powder Activated Carbon
Description:
AbstractResults of a hybrid microfiltration‐powdered activated carbon (MF‐PAC) system for the treatment of synthetic oily wastewaters with mullite and mullite‐alumina (50 % alumina content) ceramic membranes are presented.
The experiments were conducted to determine the effects of the presence of PAC on MF process performance in terms of flux decline, membrane fouling, and total organic carbon (TOC) rejection.
The experimental results demonstrate that PAC addition at low concentration (200–400 ppm) increases permeate flux by 19.
6 % for mullite and 61 % for mullite‐alumina MF membranes.
However, high PAC concentration (1200 ppm) decreases the permeate flux by 22 % for mullite and 25 % for mullite‐alumina MF membranes.
Also, TOC rejection increases from 93.
8 to 97.
4 % for mullite and from 89.
6 to 92.
4 % for mullite‐alumina MF membranes.

Related Results

Review of Hollow Fiber (HF) Membrane Filtration Technology for the Treatment of Oily Wastewater: Applications and Challenges
Review of Hollow Fiber (HF) Membrane Filtration Technology for the Treatment of Oily Wastewater: Applications and Challenges
Oily wastewater has been recognized as a threat to the environment due to its hazardous nature and it can negatively affect the ecosystem, and threaten wildlife and human health. P...
[RETRACTED] Gro-X Male Enhancement | Safely Grow Your Size, Sex Drive v1
[RETRACTED] Gro-X Male Enhancement | Safely Grow Your Size, Sex Drive v1
[RETRACTED]Gro-X Male Enhancement Reviews - Is It Worth the Money? Scam or Legit? Gro-X Male Enhancement Male health is very important, especially for a couple. Low sperm count an...
Ceramic-Polymer Composite Membranes for Water and Wastewater Treatment: Bridging the Big Gap between Ceramics and Polymers
Ceramic-Polymer Composite Membranes for Water and Wastewater Treatment: Bridging the Big Gap between Ceramics and Polymers
Clean water supply is an essential element for the entire sustainable human society, and the economic and technology development. Membrane filtration for water and wastewater treat...
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED]Rhino XL Reviews, NY USA: Studies show that testosterone levels in males decrease constantly with growing age. There are also many other problems that males face due ...
Microfiltration de jus de fruits et suspensions à base de fruits : faisabilité et performances d'une filtration par membranes immergées
Microfiltration de jus de fruits et suspensions à base de fruits : faisabilité et performances d'une filtration par membranes immergées
La microfiltration est largement utilisée pour la clarification, la stabilisation et la concentration de nombreuses suspensions à base de fruits (jus de fruits, agro-déchets, vin, ...
Analysis Of Exhaust Volume Reduction In Oily Water Separator At SS. GOLDEN ISAIA
Analysis Of Exhaust Volume Reduction In Oily Water Separator At SS. GOLDEN ISAIA
An oily water separator is an auxiliary engine on board that is used to prevent the mixing of oil and water with density differences. The oily water separator is very important on ...
OPTIMASI PENURUNAN NILAI BOD, COD DAN TSS LIMBAH CAIR INDUSTRI TAPIOKA MENGGUNAKAN ARANG AKTIF DARI AMPAS KOPI
OPTIMASI PENURUNAN NILAI BOD, COD DAN TSS LIMBAH CAIR INDUSTRI TAPIOKA MENGGUNAKAN ARANG AKTIF DARI AMPAS KOPI
Activated carbon from coffee dregs for TSS, BOD and COD removal of tapioca industrial wastewater has been developed. The research aimed to know the quality of activated carbon from...
Use of Organic Solvent Nanofiltration (OSN) membranes for Counter-Current Chromatography (CCC) solvent recovery
Use of Organic Solvent Nanofiltration (OSN) membranes for Counter-Current Chromatography (CCC) solvent recovery
Solvent resistant membranes are a relatively new technology which has the potential to expand the possible utilities of membranes for process industries. Little is known in terms o...

Back to Top