Spectrophotometric Analysis Evaluating Apical Microleakage in Retrograde Filling using GIC, MTA and Biodentine: An in-vitro study

View through CrossRef
Abstract Background The present study compares the apical microleakage of three different root-end filling materials in which the retrograde cavity is prepared by two different burs.Methods Eighty extracted single rooted maxillary and mandibular premolars were taken. Root canal treatment was completed. Apical 3 mm of all the teeth were resected with diamond disk. The tooth were divided into four groups with two subgroups for each group containing 10 tooth (N= 10) as: Group IA (Negative Control and IB (Positive Control); Group IIA and IIB: Prepared with round carbide bur and round diamond bur respectively, filled with GIC; Group IIIA and IIIB: Prepared with round carbide bur and round diamond bur respectively, filled with MTA; Group IVA and IVB: Prepared with round carbide bur and round diamond bur, filled with Biodentine. After applying two coats of nail varnish leaving apical 3 mm (except for negative control group) all teeth were immersed in 2% methylene blue for 3 days and again in 65% nitric acid for next 3 days for extraction of dye. The obtained solution was then transferred to eppendorf tube and centrifuged in microcentrifuges at 14,000 revolution per minutes (RPM) for 5 minutes. Optical density or absorbance of the supernatant solution was measured with UV spectrophotometer at 550 nm.Results The absorbance of the supernatant solution after dye extraction is decreasing in the order of positive control> GIC> MTA> Biodentine> negative control group. The significant difference was observed between GIC and MTA (p=0.0001) and GIC and Biodentine (p=0.0001) with two different burs but statistically non-significant difference was observed between MTA and Biodentine with Carbide bur (p=0.127) and Diamond bur (p=0.496) respectively.Conclusions Within the limitations of the present study, it can be concluded that Biodentine and MTA showed less microleakage as compared to GIC. There is no significant difference between mean microleakage of MTA and Biodentine. However, the mean OD of the Biodentine was least of all evaluated materials. Preparation of the root-end using round carbide bur as well as round diamond burs showed comparable microleakage for all three filling materials.
Title: Spectrophotometric Analysis Evaluating Apical Microleakage in Retrograde Filling using GIC, MTA and Biodentine: An in-vitro study
Description:
Abstract Background The present study compares the apical microleakage of three different root-end filling materials in which the retrograde cavity is prepared by two different burs.
Methods Eighty extracted single rooted maxillary and mandibular premolars were taken.
Root canal treatment was completed.
Apical 3 mm of all the teeth were resected with diamond disk.
The tooth were divided into four groups with two subgroups for each group containing 10 tooth (N= 10) as: Group IA (Negative Control and IB (Positive Control); Group IIA and IIB: Prepared with round carbide bur and round diamond bur respectively, filled with GIC; Group IIIA and IIIB: Prepared with round carbide bur and round diamond bur respectively, filled with MTA; Group IVA and IVB: Prepared with round carbide bur and round diamond bur, filled with Biodentine.
After applying two coats of nail varnish leaving apical 3 mm (except for negative control group) all teeth were immersed in 2% methylene blue for 3 days and again in 65% nitric acid for next 3 days for extraction of dye.
The obtained solution was then transferred to eppendorf tube and centrifuged in microcentrifuges at 14,000 revolution per minutes (RPM) for 5 minutes.
Optical density or absorbance of the supernatant solution was measured with UV spectrophotometer at 550 nm.
Results The absorbance of the supernatant solution after dye extraction is decreasing in the order of positive control> GIC> MTA> Biodentine> negative control group.
The significant difference was observed between GIC and MTA (p=0.
0001) and GIC and Biodentine (p=0.
0001) with two different burs but statistically non-significant difference was observed between MTA and Biodentine with Carbide bur (p=0.
127) and Diamond bur (p=0.
496) respectively.
Conclusions Within the limitations of the present study, it can be concluded that Biodentine and MTA showed less microleakage as compared to GIC.
There is no significant difference between mean microleakage of MTA and Biodentine.
However, the mean OD of the Biodentine was least of all evaluated materials.
Preparation of the root-end using round carbide bur as well as round diamond burs showed comparable microleakage for all three filling materials.

Related Results

Spectrophotometric Analysis Evaluating Apical Microleakage in Retrograde Filling using GIC, MTA and Biodentine: An in-vitro study
Spectrophotometric Analysis Evaluating Apical Microleakage in Retrograde Filling using GIC, MTA and Biodentine: An in-vitro study
Abstract Background The present study compares the apical microleakage of three different root-end filling materials in which the retrograde cavity is prepared by two diffe...
Spectrophotometric Analysis Evaluating Apical Microleakage in Retrograde Filling using GIC, MTA and Biodentine: An in-vitro study
Spectrophotometric Analysis Evaluating Apical Microleakage in Retrograde Filling using GIC, MTA and Biodentine: An in-vitro study
Abstract Background The present study compares the apical microleakage of three different root-end filling materials in which the retrograde cavity is prepared by two diffe...
Comparative Evaluation of Efficacy of Mineral Trioxide Aggregate and Biodentine as Pulpotomy Agents in Primary Molars
Comparative Evaluation of Efficacy of Mineral Trioxide Aggregate and Biodentine as Pulpotomy Agents in Primary Molars
Background: Pulpotomy is a very common vital pulp therapy used in pediatric dentistry. It is performed in cases of reversible pulpitis of primary teeth, or sometimes in young perma...
Pengaruh Jus Buah Kemasan Dengan pH Asam Terhadap Perubahan Warna pada Glass Ionomer Cements dan Giomer
Pengaruh Jus Buah Kemasan Dengan pH Asam Terhadap Perubahan Warna pada Glass Ionomer Cements dan Giomer
Background: GIC filling materials are sensitive to water contamination, brittle, and easily fractured. To improve the shortcomings of GIC, another material is used, namely Giomer w...
Ability of different methods to fill retrograde cavities with MTA
Ability of different methods to fill retrograde cavities with MTA
The Mineral Trioxide Aggregate (MTA) has excellent biological property. However, its consistency makes it difficult to be inserted into retrograde cavities. Objective: To evaluate ...

Back to Top