Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Superresolution fluorescence microscopy with structured illumination

View through CrossRef
The resolution of a conventional fluorescence microscope image is diffraction limited which achieves a spatial resolution of 200nm lateral and 500nm axial. Recently, many superresolution fluorescence microscopy techniques have been developed which allow the observation of many biological structures beyond the diffraction limit. Structured illumination microscopy (SIM) is one of them. The principle of SIM is based on using a harmonic light grid which down modulates the high spatial frequencies of the sample into the observable region of the microscope. The resolution enhancement is highly dependent on the reconstruction technique, which restores the high spatial frequencies of the sample to their original position. Common SIM reconstructions require the perfect knowledge of the illumination pattern. However, to perfectly control the harmonic illumination patterns on the sample plane is not easy in experimental implementations and this makes the experimental setup very technical. Reconstructing SIM images assuming the perfect knowledge of the illumination intensity patterns may, therefore, introduce artifacts on the estimated sample due to the misalignment of the grid that can occur during experimental acquisitions. To tackle this drawback of SIM, in this these, we have developed blind-SIM reconstruction strategies which are independent of the illumination patterns. Using the 3D blind-SIM reconstruction strategies we extended the harmonic SIM to speckle illumination microscopy which uses random unknown speckle patterns that need no control, unlike the harmonic grid patterns. For harmonic-SIM images, since incorporating some information about illumination patterns is valuable, we have developed a 3D positive filtered blind-SIM reconstruction which confines the iterative estimation of the illuminations in the vicinity of the Fourier peaks (using carefully designed Fourier filter masks) in the Fourier space. Using blind-SIM reconstruction techniques a lateral resolution of about 100nm and axial resolution of about 200nm is obtained in both speckle and harmonic SIM. In addition, to reduce the out-of-focus problem in widefield images, a simple computational technique which is based on reconstructing 2D data with 3D PSF is developed based on blind-SIM reconstruction. Moreover, to combine the functionalities of SIM and light sheet microscopy, as a proof of concept, we have developed a simple microscope setup which produces a structured light sheet illumination pattern. La microscopie de fluorescence optique est l’un des outils les plus puissants pour étudier les structures cellulaires et moléculaires au niveau subcellulaire. La résolution d’une image de microscope conventionnel à fluorescence est limitée par la diffraction, ce qui permet d’obtenir une résolution spatiale latérale de 200nm et axiale de 500nm. Récemment, de nombreuses techniques de microscopie de fluorescence de super-résolution ont été développées pour permettre d’observer de nombreuses structures biologiques au-delà de la limite de diffraction. La microscopie d’illumination structurée (SIM) est l’une de ces technologies. Le principe de la SIM est basé sur l’utilisation d’une grille de lumière harmonique qui permet de translater les hautes fréquences spatiales de l’échantillon vers la région d’observation du microscope. L’amélioration de la résolution de cette technologie de microscopie dépend fortement de la technique de reconstruction, qui rétablit les hautes fréquences spatiales de l’échantillon dans leur position d’origine. Les méthodes classiques de reconstruction SIM nécessitent une connaissance parfaite de l’illumination de l’échantillon. Cependant, l’implémentation d’un contrôle parfait de l’illumination harmonique sur le plan de l’échantillon n’est pas facile expérimentalement et il présente un grand défi. L’hypothèse de la connaissance parfaite de l’intensité de la lumière illuminant l’échantillon en SIM peut donc introduire des artefacts sur l’image reconstruite de l’échantillon, à cause des erreurs d’alignement de la grille qui peuvent se présenter lors de l’acquisition expérimentale. Afin de surmonter ce défi, nous avons développé dans cette thèse des stratégies de reconstruction «aveugle» qui sont indépendantes de d’illumination. À l’aide de ces stratégies de reconstruction dites «blind-SIM», nous avons étendu la SIM harmonique pour l’appliquer aux cas de «SIM-speckle» qui utilisent des illuminations aléatoires et inconnues qui contrairement à l’illumination harmonique, ne nécessitent pas de controle. Comme il est utile de récupérer des informations sur l’illumination en SIM harmonique, nous avons développé une reconstruction blind-SIM tridimensionnel et filtrée qui confine l’estimation itérative des illuminations au voisinage des pics dans l’espace de Fourier, en utilisant des masques de filtre de Fourier soigneusement conçus. En utilisant des techniques de reconstruction blind-SIM, une résolution latérale d’environ 100 nm et une résolution axiale d’environ 200 nm sont obtenues, à la fois en SIM harmonique et en SIM speckle. En outre, pour réduire le problème de focalisation dans les images de champ large, une technique de calcul simple qui repose sur la reconstruction bidimensionnel de données à partir de PSF tridimensionnel est développée. En outre, afin de combiner à la fois les fonctionnalités de la SIM et de la microscopie á nappe de lumière, en tant que preuve de concept, nous avons développé une configuration de microscope simple qui produit une nappe de lumière structurée
Universitat Politècnica de Catalunya
Title: Superresolution fluorescence microscopy with structured illumination
Description:
The resolution of a conventional fluorescence microscope image is diffraction limited which achieves a spatial resolution of 200nm lateral and 500nm axial.
Recently, many superresolution fluorescence microscopy techniques have been developed which allow the observation of many biological structures beyond the diffraction limit.
Structured illumination microscopy (SIM) is one of them.
The principle of SIM is based on using a harmonic light grid which down modulates the high spatial frequencies of the sample into the observable region of the microscope.
The resolution enhancement is highly dependent on the reconstruction technique, which restores the high spatial frequencies of the sample to their original position.
Common SIM reconstructions require the perfect knowledge of the illumination pattern.
However, to perfectly control the harmonic illumination patterns on the sample plane is not easy in experimental implementations and this makes the experimental setup very technical.
Reconstructing SIM images assuming the perfect knowledge of the illumination intensity patterns may, therefore, introduce artifacts on the estimated sample due to the misalignment of the grid that can occur during experimental acquisitions.
To tackle this drawback of SIM, in this these, we have developed blind-SIM reconstruction strategies which are independent of the illumination patterns.
Using the 3D blind-SIM reconstruction strategies we extended the harmonic SIM to speckle illumination microscopy which uses random unknown speckle patterns that need no control, unlike the harmonic grid patterns.
For harmonic-SIM images, since incorporating some information about illumination patterns is valuable, we have developed a 3D positive filtered blind-SIM reconstruction which confines the iterative estimation of the illuminations in the vicinity of the Fourier peaks (using carefully designed Fourier filter masks) in the Fourier space.
Using blind-SIM reconstruction techniques a lateral resolution of about 100nm and axial resolution of about 200nm is obtained in both speckle and harmonic SIM.
In addition, to reduce the out-of-focus problem in widefield images, a simple computational technique which is based on reconstructing 2D data with 3D PSF is developed based on blind-SIM reconstruction.
Moreover, to combine the functionalities of SIM and light sheet microscopy, as a proof of concept, we have developed a simple microscope setup which produces a structured light sheet illumination pattern.
La microscopie de fluorescence optique est l’un des outils les plus puissants pour étudier les structures cellulaires et moléculaires au niveau subcellulaire.
La résolution d’une image de microscope conventionnel à fluorescence est limitée par la diffraction, ce qui permet d’obtenir une résolution spatiale latérale de 200nm et axiale de 500nm.
Récemment, de nombreuses techniques de microscopie de fluorescence de super-résolution ont été développées pour permettre d’observer de nombreuses structures biologiques au-delà de la limite de diffraction.
La microscopie d’illumination structurée (SIM) est l’une de ces technologies.
Le principe de la SIM est basé sur l’utilisation d’une grille de lumière harmonique qui permet de translater les hautes fréquences spatiales de l’échantillon vers la région d’observation du microscope.
L’amélioration de la résolution de cette technologie de microscopie dépend fortement de la technique de reconstruction, qui rétablit les hautes fréquences spatiales de l’échantillon dans leur position d’origine.
Les méthodes classiques de reconstruction SIM nécessitent une connaissance parfaite de l’illumination de l’échantillon.
Cependant, l’implémentation d’un contrôle parfait de l’illumination harmonique sur le plan de l’échantillon n’est pas facile expérimentalement et il présente un grand défi.
L’hypothèse de la connaissance parfaite de l’intensité de la lumière illuminant l’échantillon en SIM peut donc introduire des artefacts sur l’image reconstruite de l’échantillon, à cause des erreurs d’alignement de la grille qui peuvent se présenter lors de l’acquisition expérimentale.
Afin de surmonter ce défi, nous avons développé dans cette thèse des stratégies de reconstruction «aveugle» qui sont indépendantes de d’illumination.
À l’aide de ces stratégies de reconstruction dites «blind-SIM», nous avons étendu la SIM harmonique pour l’appliquer aux cas de «SIM-speckle» qui utilisent des illuminations aléatoires et inconnues qui contrairement à l’illumination harmonique, ne nécessitent pas de controle.
Comme il est utile de récupérer des informations sur l’illumination en SIM harmonique, nous avons développé une reconstruction blind-SIM tridimensionnel et filtrée qui confine l’estimation itérative des illuminations au voisinage des pics dans l’espace de Fourier, en utilisant des masques de filtre de Fourier soigneusement conçus.
En utilisant des techniques de reconstruction blind-SIM, une résolution latérale d’environ 100 nm et une résolution axiale d’environ 200 nm sont obtenues, à la fois en SIM harmonique et en SIM speckle.
En outre, pour réduire le problème de focalisation dans les images de champ large, une technique de calcul simple qui repose sur la reconstruction bidimensionnel de données à partir de PSF tridimensionnel est développée.
En outre, afin de combiner à la fois les fonctionnalités de la SIM et de la microscopie á nappe de lumière, en tant que preuve de concept, nous avons développé une configuration de microscope simple qui produit une nappe de lumière structurée.

Related Results

Theoretical study of wide-field fluorescence microscopy based on dynamic speckle illumination
Theoretical study of wide-field fluorescence microscopy based on dynamic speckle illumination
In order to obtain the internal fine structure of biological tissues and living cells, the microscopic imaging technology is required to be capable of microscopy. In the wide-field...
Large-field Astronomical Image Restoration and Superresolution Reconstruction using Deep Learning
Large-field Astronomical Image Restoration and Superresolution Reconstruction using Deep Learning
Abstract The existing astronomical image restoration and superresolution reconstruction methods have problems such as low efficiency and poor results when dealing wi...
Superresolution based on coherent thermal radiation with selective information
Superresolution based on coherent thermal radiation with selective information
Abstract We reexamine superresolution methods that may have been overlooked by previous optical microscopy techniques. For a one-dimensional (1D) system, we show that max...
Focusing Characteristics of an Optical Head with Superresolution Using a High-Aspect-Ratio Red Laser Diode
Focusing Characteristics of an Optical Head with Superresolution Using a High-Aspect-Ratio Red Laser Diode
The focusing characteristics, when using a superresolution technique, for a high-aspect-ratio laser beam were investigated theoretically. The spot size, sidelobe intensity, and...
Texture-Guided Multisensor Superresolution for Remotely Sensed Images
Texture-Guided Multisensor Superresolution for Remotely Sensed Images
This paper presents a novel technique, namely texture-guided multisensor superresolution (TGMS), for fusing a pair of multisensor multiresolution images to enhance the spatial reso...
Study on wide-field fluorescence sectioning microscopy based on dynamic speckle illumination
Study on wide-field fluorescence sectioning microscopy based on dynamic speckle illumination
In this paper, we present a novel wide-field fluorescence sectioning microscopy in which speckle patterns are produced on the sample for illumination. The speckle pattern is dynami...
SURG-05. EXPERIENCE PROFILING OF FLUORESCENCE-GUIDED SURGERY FOR GLIOMAS
SURG-05. EXPERIENCE PROFILING OF FLUORESCENCE-GUIDED SURGERY FOR GLIOMAS
Abstract Numerous studies reported a usefulness of 5-ALA fluorescence-guided surgery (FGS) in high grade gliomas. However, fluorescence pattern and intensity is vari...

Back to Top