Diagnostic performance of IVUS-FFR analysis based on generative adversarial network and bifurcation fractal law for assessing myocardial ischemia
View through CrossRef
BackgroundIVUS-based virtual FFR (IVUS-FFR) can provide additional functional assessment information to IVUS imaging for the diagnosis of coronary stenosis. IVUS image segmentation and side branch blood flow can affect the accuracy of virtual FFR. The purpose of this study was to evaluate the diagnostic performance of an IVUS-FFR analysis based on generative adversarial networks and bifurcation fractal law, using invasive FFR as a reference.MethodIn this study, a total of 108 vessels were retrospectively collected from 87 patients who underwent IVUS and invasive FFR. IVUS-FFR was performed by analysts who were blinded to invasive FFR. We evaluated the diagnostic performance and computation time of IVUS-FFR, and compared it with that of the FFR-branch (considering side branch blood flow by manually extending the side branch from the bifurcation ostia). We also compared the effects of three bifurcation fractal laws on the accuracy of IVUS-FFR.ResultThe diagnostic accuracy, sensitivity, and specificity for IVUS-FFR to identify invasive FFR≤0.80 were 90.7% (95% CI, 83.6–95.5), 89.7% (95% CI, 78.8–96.1), 92.0% (95% CI, 80.8–97.8), respectively. A good correlation and agreement between IVUS-FFR and invasive FFR were observed. And the average computation time of IVUS-FFR was shorter than that of FFR-branch. In addition to this, we also observe that the HK model is the most accurate among the three bifurcation fractal laws.ConclusionOur proposed IVUS-FFR analysis correlates and agrees well with invasive FFR and shows good diagnostic performance. Compared with FFR-branch, IVUS-FFR has the same level of diagnostic performance with significantly lower computation time.
Title: Diagnostic performance of IVUS-FFR analysis based on generative adversarial network and bifurcation fractal law for assessing myocardial ischemia
Description:
BackgroundIVUS-based virtual FFR (IVUS-FFR) can provide additional functional assessment information to IVUS imaging for the diagnosis of coronary stenosis.
IVUS image segmentation and side branch blood flow can affect the accuracy of virtual FFR.
The purpose of this study was to evaluate the diagnostic performance of an IVUS-FFR analysis based on generative adversarial networks and bifurcation fractal law, using invasive FFR as a reference.
MethodIn this study, a total of 108 vessels were retrospectively collected from 87 patients who underwent IVUS and invasive FFR.
IVUS-FFR was performed by analysts who were blinded to invasive FFR.
We evaluated the diagnostic performance and computation time of IVUS-FFR, and compared it with that of the FFR-branch (considering side branch blood flow by manually extending the side branch from the bifurcation ostia).
We also compared the effects of three bifurcation fractal laws on the accuracy of IVUS-FFR.
ResultThe diagnostic accuracy, sensitivity, and specificity for IVUS-FFR to identify invasive FFR≤0.
80 were 90.
7% (95% CI, 83.
6–95.
5), 89.
7% (95% CI, 78.
8–96.
1), 92.
0% (95% CI, 80.
8–97.
8), respectively.
A good correlation and agreement between IVUS-FFR and invasive FFR were observed.
And the average computation time of IVUS-FFR was shorter than that of FFR-branch.
In addition to this, we also observe that the HK model is the most accurate among the three bifurcation fractal laws.
ConclusionOur proposed IVUS-FFR analysis correlates and agrees well with invasive FFR and shows good diagnostic performance.
Compared with FFR-branch, IVUS-FFR has the same level of diagnostic performance with significantly lower computation time.
Related Results
Physiological disease pattern as assessed by PPGI in vessels with FFR and iFR discordance
Physiological disease pattern as assessed by PPGI in vessels with FFR and iFR discordance
Abstract
Background
Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) disagree on the hemodynamic significan...
P2705Hybrid QFR-FFR decision making strategy for revascularization
P2705Hybrid QFR-FFR decision making strategy for revascularization
Abstract
Background
Measurement of the fractional flow reserve (FFR) has become a standard practice for revascularization decisi...
Ischemia-Guided Coronary Revascularization Following Lower-Extremity Revascularization Improves 5-Year Survival of Patients With Chronic Limb-Threatening Ischemia
Ischemia-Guided Coronary Revascularization Following Lower-Extremity Revascularization Improves 5-Year Survival of Patients With Chronic Limb-Threatening Ischemia
Purpose:
To determine whether diagnosis of asymptomatic (silent) coronary ischemia using coronary computed tomography (CT)-derived fracti...
Diagnostic performance and clinical implications for enhancing a hybrid quantitative flow ratio and fractional flow reserve revascularization decision making strategy
Diagnostic performance and clinical implications for enhancing a hybrid quantitative flow ratio and fractional flow reserve revascularization decision making strategy
Abstract
Background
Fractional flow reserve (FFR) adoption persists low mainly due to procedural and operator related factors as...
Virtual image -based FFR technologies
Virtual image -based FFR technologies
Πρώτο Μέρος. Εισαγωγή: Μη επεμβατικές μέθοδοι εκτίμησης της κλασματικής εφεδρείας ροής (FFR) μελετώνται ενεργά, με στόχο να ξεπεράσουν τα προβλήματα της επεμβατικής συμβατικής εκτί...
Diagnostic efficacy of CCTA and CT-FFR based on risk factors for myocardial ischemia
Diagnostic efficacy of CCTA and CT-FFR based on risk factors for myocardial ischemia
Abstract
Background
Coronary artery coronary computed tomography angiography (CCTA) can observe the degree of coronary artery stenosis and fractiona...
Real world economic evaluation of CT-FFR in patients with suspected coronary artery disease
Real world economic evaluation of CT-FFR in patients with suspected coronary artery disease
Abstract
Background
Incorporation of CT-derived fractional flow reserve (CT-FFR) enhances the precision of Coronary CT Angiograp...
020 Comparison of fractional flow reserve measurements obtained using central vs distal peripheral intravenous adenosine infusion to induce hyperaemia
020 Comparison of fractional flow reserve measurements obtained using central vs distal peripheral intravenous adenosine infusion to induce hyperaemia
Introduction
Measurement of fractional flow reserve (FFR) permits physiological evaluation of coronary lesions. Maximal hyperaemia is required and adenosine is mo...