Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparing Guided Surgical Endodontics Using Static Guidance, Dynamic Navigation, and Augmented Reality: A Systematic Review and Meta-analysis

View through CrossRef
Abstract Endodontic microsurgery is a treatment for persistent periapical pathology, where precision in root-end surgery is crucial for success. Advances in digital technology have introduced guided endodontic microsurgery, incorporating static guidance (SG), dynamic navigation (DN), and augmented reality (AR) to enhance surgical accuracy and efficiency. This systematic review and meta-analysis aimed to evaluate and compare the accuracy of SG, DN, and AR in endodontic microsurgery. This review followed PRISMA guidelines. The protocol was registered in the International Prospective Register of Systematic Reviews database (CRD42024583867). A comprehensive search of PubMed, Scopus, and Google Scholar was conducted from inception to February 2026. Studies comparing SG, DN, and AR in endodontic microsurgery were included. Risk of bias was assessed using ROBINS-I V2, the JBI Checklist, and the QUIN tool. Meta-analysis and subgroup analysis were performed on studies with comparable accuracy parameters. Heterogeneity was assessed using Cochran's Q-test and I 2 statistics. Thirty-three studies met the predefined inclusion criteria: 1 nonrandomized clinical trial, 1 case series, and 31 in vitro and cadaver studies. Due to limited clinical studies, the clinical trial and case series identified were synthesized qualitatively, while the meta-analysis pooled only in vitro and cadaveric studies. A meta-analysis demonstrated that SG and DN significantly reduced 3D global deviation at the bur tip compared with FH (p < 0.01). While the drilled root length error did not differ between SG and DN, DN exhibited significantly greater resection angle deviation than SG (p < 0.01). AR showed potential benefits in accuracy, but the data were insufficient for meta-analysis. SG required the least operating time. SG and DN enhance accuracy and efficiency in endodontic microsurgery compared with freehand techniques in in vitro and cadaveric studies. Standardized outcome measures and further clinical trials with long-term follow-up are needed to validate these findings. Further clinical studies with long-term follow-up are warranted to confirm the effects of guided surgical endodontics on clinical outcomes.
Title: Comparing Guided Surgical Endodontics Using Static Guidance, Dynamic Navigation, and Augmented Reality: A Systematic Review and Meta-analysis
Description:
Abstract Endodontic microsurgery is a treatment for persistent periapical pathology, where precision in root-end surgery is crucial for success.
Advances in digital technology have introduced guided endodontic microsurgery, incorporating static guidance (SG), dynamic navigation (DN), and augmented reality (AR) to enhance surgical accuracy and efficiency.
This systematic review and meta-analysis aimed to evaluate and compare the accuracy of SG, DN, and AR in endodontic microsurgery.
This review followed PRISMA guidelines.
The protocol was registered in the International Prospective Register of Systematic Reviews database (CRD42024583867).
A comprehensive search of PubMed, Scopus, and Google Scholar was conducted from inception to February 2026.
Studies comparing SG, DN, and AR in endodontic microsurgery were included.
Risk of bias was assessed using ROBINS-I V2, the JBI Checklist, and the QUIN tool.
Meta-analysis and subgroup analysis were performed on studies with comparable accuracy parameters.
Heterogeneity was assessed using Cochran's Q-test and I 2 statistics.
Thirty-three studies met the predefined inclusion criteria: 1 nonrandomized clinical trial, 1 case series, and 31 in vitro and cadaver studies.
Due to limited clinical studies, the clinical trial and case series identified were synthesized qualitatively, while the meta-analysis pooled only in vitro and cadaveric studies.
A meta-analysis demonstrated that SG and DN significantly reduced 3D global deviation at the bur tip compared with FH (p < 0.
01).
While the drilled root length error did not differ between SG and DN, DN exhibited significantly greater resection angle deviation than SG (p < 0.
01).
AR showed potential benefits in accuracy, but the data were insufficient for meta-analysis.
SG required the least operating time.
SG and DN enhance accuracy and efficiency in endodontic microsurgery compared with freehand techniques in in vitro and cadaveric studies.
Standardized outcome measures and further clinical trials with long-term follow-up are needed to validate these findings.
Further clinical studies with long-term follow-up are warranted to confirm the effects of guided surgical endodontics on clinical outcomes.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical activi...
MEMBANGUN BRAND EQUITY UMKM IKAN ASAP MENGGUNAKAN TEKNOLOGI AUGMENTED REALITY MELALUI LITERASI PEMASARAN
MEMBANGUN BRAND EQUITY UMKM IKAN ASAP MENGGUNAKAN TEKNOLOGI AUGMENTED REALITY MELALUI LITERASI PEMASARAN
Abstrak UMKM merupakan salah satu roda penggerak perekenomian nasional. Terbukti bahwa UMKM telah membantu 61,97% PDB Indonesia. Namun sayangnya, masih banyak produsen yang memili...
Augmented Reality for Smoking Cessation: Development and Usability Study (Preprint)
Augmented Reality for Smoking Cessation: Development and Usability Study (Preprint)
BACKGROUND The recent widespread availability of augmented reality via smartphone offers an opportunity to translate cue exposure therapy for smoking cessat...
Aircraft Precipitation Static Certification
Aircraft Precipitation Static Certification
<div class="section abstract"> <div class="htmlview paragraph">Aircraft surface precipitation static (p-static) charge can be generated when aircraft fly through ice ...
Navace: A New Approach To Precision, Work Area Ocean Navigation
Navace: A New Approach To Precision, Work Area Ocean Navigation
ABSTRACT NAVACE is a revolutionary navigation system under development by Electrospace Systems, Inc. NAVACE utilizes a concept of ocean bottom and sub-bottom feat...
Augmented reality books: concepts, typology, tools
Augmented reality books: concepts, typology, tools
The article discussed the usage of augmented reality books in educational process. The object of research is augmented reality books. The subject of the study is the concepts and c...
Augmented-Reality Displays
Augmented-Reality Displays
Recent technological advancements in virtual environment equipment have led to the development of augmented reality displays for applications in medicine, manufacturing, and scient...

Back to Top