PERIPROSTHETIC FRACTURE RATES USING COLLARED STEMS IN UNCEMENTED PRIMARY TOTAL HIP ARTHROPLASTY WITH A POSTERIOR APPROACH
View through CrossRef
Periprosthetic femur fracture (PFF) is a major complication following total hip arthroplasty (THA) that carries significant morbidity, mortality, and economic burden. Currently, uncemented stems are highly preferred in primary THA, but have been associated with higher risk of PFF compared to cemented stems. The use of collared stems in uncemented primary THA has shown promise in reducing PFF rates postoperatively.This retrospective study included 2,294 uncemented primary THAs using the posterior approach performed by two attending surgeons from January 2016 to December 2022. Both surgeons switched from a collarless femoral stem design to a collared design in May 2020. Data was collected regarding stem design, frequency of PFF, and requirement for revision surgery. Periprosthetic fractures were identified and confirmed using medical records and/or radiographic imaging. Fracture rates and percentages between collared and collarless stems were then analyzed. A Fisher's Exact Test was performed to determine if there was a significant association between collared and collarless stem use on PFF rates.A total of 2,294 uncemented primary THAs performed by 2 surgeons were eligible for analysis. 903 (39.4%) patients received a collared stem, and 1,391 (60.6%) patients received a collarless stem. In total, 14 (0.6%) PFFs occurred over the study period. There was 1 fracture (0.1%) out of 903 collared stems, and 13 fractures (0.9%) out of 1,391 collarless stems (p = 0.012).Collared stems were associated with a significant decrease in PFF rate when compared to collarless stems in uncemented primary THA. Future studies are encouraged to continue to investigate PFF and other complication rates with the use of a collared stem design.
British Editorial Society of Bone & Joint Surgery
Title: PERIPROSTHETIC FRACTURE RATES USING COLLARED STEMS IN UNCEMENTED PRIMARY TOTAL HIP ARTHROPLASTY WITH A POSTERIOR APPROACH
Description:
Periprosthetic femur fracture (PFF) is a major complication following total hip arthroplasty (THA) that carries significant morbidity, mortality, and economic burden.
Currently, uncemented stems are highly preferred in primary THA, but have been associated with higher risk of PFF compared to cemented stems.
The use of collared stems in uncemented primary THA has shown promise in reducing PFF rates postoperatively.
This retrospective study included 2,294 uncemented primary THAs using the posterior approach performed by two attending surgeons from January 2016 to December 2022.
Both surgeons switched from a collarless femoral stem design to a collared design in May 2020.
Data was collected regarding stem design, frequency of PFF, and requirement for revision surgery.
Periprosthetic fractures were identified and confirmed using medical records and/or radiographic imaging.
Fracture rates and percentages between collared and collarless stems were then analyzed.
A Fisher's Exact Test was performed to determine if there was a significant association between collared and collarless stem use on PFF rates.
A total of 2,294 uncemented primary THAs performed by 2 surgeons were eligible for analysis.
903 (39.
4%) patients received a collared stem, and 1,391 (60.
6%) patients received a collarless stem.
In total, 14 (0.
6%) PFFs occurred over the study period.
There was 1 fracture (0.
1%) out of 903 collared stems, and 13 fractures (0.
9%) out of 1,391 collarless stems (p = 0.
012).
Collared stems were associated with a significant decrease in PFF rate when compared to collarless stems in uncemented primary THA.
Future studies are encouraged to continue to investigate PFF and other complication rates with the use of a collared stem design.
Related Results
Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register Evaluation of 170,413 operations
Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register Evaluation of 170,413 operations
BACKGROUND AND PURPOSE: Since the introduction of total hip arthroplasty (THA) in Sweden, both components have most commonly been cemented. A decade ago the frequency of uncemented...
Vitamin D and periprosthetic infection: Review of literature (Preprint)
Vitamin D and periprosthetic infection: Review of literature (Preprint)
BACKGROUND
Infections are rare events in arthroplasty surgeries, occurring in only 0.5% to 2% of procedures. It significantly impacts all involved parts (pa...
Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Running is a popular form of exercise that is accompanied by many health benefits. However, running also comes with a risk of overuse injuries. Women have a higher risk for overuse...
A Randomized Study Comparing Uncemented and Hybrid Hip Replacements in Young Patients with Osteonecrosis Femoral Head
A Randomized Study Comparing Uncemented and Hybrid Hip Replacements in Young Patients with Osteonecrosis Femoral Head
Objectives
There is a scarcity of data comparing cemented and hybrid implants for total hip arthroplasty in relatively younger patients. The aim was to evaluate the clinical outcom...
Comparison of functional outcome between Bipolar Hemiarthroplasty and total Hip Arthroplasty for displaced femoral neck fractures in elderly patients
Comparison of functional outcome between Bipolar Hemiarthroplasty and total Hip Arthroplasty for displaced femoral neck fractures in elderly patients
Objectives: The intention of this study to compare functional outcomes between Total Hip Arthroplasty and Bipolar Hemi Arthroplasty for displaced femoral neck fracture after 3 mont...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
Abstract
Despite advancements in fracture prediction tools and osteoporosis management, hip fractures remain a significant consequence of bone fr...
Revise and remember : managing hip resurfacing implant recall
Revise and remember : managing hip resurfacing implant recall
<h4>Background</h4><p dir="ltr">Total hip arthroplasty (THA) with metal-on-polyethylene articulation provides excellent clinical outcomes but remains associated w...