Seismic Capacity Assessment of Confined Brick Masonry Building: An Experimental Approach
View through CrossRef
Brick masonry is widely used for building construction throughout the world. However, unreinforced brick masonry buildings performed poorly in the 2005 Kashmir earthquake, in Pakistan, resulting in a decline in the use of brick masonry. In order to investigate and quantify the performance of brick masonry against the seismic forces by confining it through typical stiffer, line elements (column and beams), a full‐scaled room model of an area 3048 × 3658 mm (10 × 12 ft) and height of 3353 mm (11 ft) was constructed using confined brick masonry. The model was tested under quasistatic loading system. Crack pattern was noted at the end of each loading cycle. The response of the model was interpreted through a hysteresis curve, which was then idealized by a bilinear curve. A comparison of the results has been made with four different studies done on the similar model made of unreinforced brick masonry before and after retrofitting and unreinforced concrete block masonry before and after retrofitting previously tested at the same testing facility.
Title: Seismic Capacity Assessment of Confined Brick Masonry Building: An Experimental Approach
Description:
Brick masonry is widely used for building construction throughout the world.
However, unreinforced brick masonry buildings performed poorly in the 2005 Kashmir earthquake, in Pakistan, resulting in a decline in the use of brick masonry.
In order to investigate and quantify the performance of brick masonry against the seismic forces by confining it through typical stiffer, line elements (column and beams), a full‐scaled room model of an area 3048 × 3658 mm (10 × 12 ft) and height of 3353 mm (11 ft) was constructed using confined brick masonry.
The model was tested under quasistatic loading system.
Crack pattern was noted at the end of each loading cycle.
The response of the model was interpreted through a hysteresis curve, which was then idealized by a bilinear curve.
A comparison of the results has been made with four different studies done on the similar model made of unreinforced brick masonry before and after retrofitting and unreinforced concrete block masonry before and after retrofitting previously tested at the same testing facility.
Related Results
Improvement of Seismic Performance of Ordinary Reinforced Partially Grouted Concrete Masonry Shear Walls
Improvement of Seismic Performance of Ordinary Reinforced Partially Grouted Concrete Masonry Shear Walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
The Masonry Market is Booming in Brazil- Why?
The Masonry Market is Booming in Brazil- Why?
This paper is motivated by the keynote presentation at the 12th North American Masonry Conference in Denver, Colorado in 2015. It gives an overview on how engineered masonry became...
Experimental Comparison Between Two-Course Molded Masonry Specimen and Three-Course Extracted Masonry Specimen in Clay Masonry Structures
Experimental Comparison Between Two-Course Molded Masonry Specimen and Three-Course Extracted Masonry Specimen in Clay Masonry Structures
This study investigates the relationship between the compressive strength results of two-course molded masonry specimens and three-course masonry specimens extracted from previousl...
Brick masonry reinforcement with methyl methacrylate injection
Brick masonry reinforcement with methyl methacrylate injection
Introduction. Structural reinforcement of brick and stone masonry by grouting materials under pressure is an efficient approach to restoring the masonry integrity, and, in some cas...
Engineering Design Provisions for Prestressed Masonry, Part 1 – Masonry Stresses
Engineering Design Provisions for Prestressed Masonry, Part 1 – Masonry Stresses
Masonry can be strengthened through controlled precompression stresses which reduce or eliminate tension. In other countries, primarily the United Kingdom, prestressed masonry has ...
4D Seismic on Gullfaks
4D Seismic on Gullfaks
SUMMARY
New technologies are rapidly emerging helping to obtain optimal drainage of large reservoirs. 4D seismic is such a reservoir monitoring technique. The phy...
Seismic Frequency Enhancement for Mapping and Reservoir Characterization of Arab Formation: Case Study Onshore UAE
Seismic Frequency Enhancement for Mapping and Reservoir Characterization of Arab Formation: Case Study Onshore UAE
Abstract
Mapping and discrimination of Upper Jurassic Arab reservoirs (Arab A/B/C and D) in this 3D seismic onshore field of Abu Dhabi, is very sensitive to the seis...
Integrated Hydrocarbon Detection Based on Full Frequency Pre-Stack Seismic Inversion
Integrated Hydrocarbon Detection Based on Full Frequency Pre-Stack Seismic Inversion
Abstract
To improve the accuracy of hydrocarbon detection, seismic amplitude variation with offset (AVO), seismic amplitude variation with frequency (AVF), and direc...