Javascript must be enabled to continue!
Preamorphization-induced defects in shallow P+N junctions characterized by an ac magnetic field
View through CrossRef
ABSTRACTGermanium implantation into silicon substrate is currently used to preamorphisize the crystalline structure in order to avoid boron channeling effects in shallow P+N junction manufacturing. Nevertheless, after boron doping and rapid thermal annealing, different defects are formed within the structure, such as end of range defects which are created at the amorphous/crystalline interface. Our study concerns two types of shallow P+N junctions. These junctions were fabricated using low energy boron implantation at 3 KeV with a dose of 2×1015 cm-2 into high-energy germanium preamorphized n-type crystalline silicon substrates at 2.2 MeV with a dose of 1015 cm-2. In the first type, the preamorphization was performed at ambient temperature. In the second, the preamorphization was performed at liquid nitrogen temperature. Boron doping was followed by a Rapid Thermal Annealing (RTA) step for 15 s at 950 °C. Deep Level Transient Spectroscopy (DLTS) technique was used to characterize the defects formed in each structure. The impact of an ac magnetic field on the reverse current has been studied at a given bias, when sweeping the sample temperature. The measurements were performed under a low frequency (less than 1 kHz) magnetic field of a Vrms value of 2000 G, with sample temperature varying between 80 and 260 K. The results show a high activity of defects at low frequencies (1 and 10 Hz) for the nitrogen preamorphized sample. Moreover, this activity is observed at about 200 K which corresponds to the peak of the DLTS spectra of such sample. However, the ambient preamorphized sample characterized by a lower concentration of defects seems to be insensitive to the ac magnetic field. Therefore, it appears that the preamorphization-induced defects influence strongly the response of the junction to an applied ac magnetic field.
Springer Science and Business Media LLC
Title: Preamorphization-induced defects in shallow P+N junctions characterized by an ac magnetic field
Description:
ABSTRACTGermanium implantation into silicon substrate is currently used to preamorphisize the crystalline structure in order to avoid boron channeling effects in shallow P+N junction manufacturing.
Nevertheless, after boron doping and rapid thermal annealing, different defects are formed within the structure, such as end of range defects which are created at the amorphous/crystalline interface.
Our study concerns two types of shallow P+N junctions.
These junctions were fabricated using low energy boron implantation at 3 KeV with a dose of 2×1015 cm-2 into high-energy germanium preamorphized n-type crystalline silicon substrates at 2.
2 MeV with a dose of 1015 cm-2.
In the first type, the preamorphization was performed at ambient temperature.
In the second, the preamorphization was performed at liquid nitrogen temperature.
Boron doping was followed by a Rapid Thermal Annealing (RTA) step for 15 s at 950 °C.
Deep Level Transient Spectroscopy (DLTS) technique was used to characterize the defects formed in each structure.
The impact of an ac magnetic field on the reverse current has been studied at a given bias, when sweeping the sample temperature.
The measurements were performed under a low frequency (less than 1 kHz) magnetic field of a Vrms value of 2000 G, with sample temperature varying between 80 and 260 K.
The results show a high activity of defects at low frequencies (1 and 10 Hz) for the nitrogen preamorphized sample.
Moreover, this activity is observed at about 200 K which corresponds to the peak of the DLTS spectra of such sample.
However, the ambient preamorphized sample characterized by a lower concentration of defects seems to be insensitive to the ac magnetic field.
Therefore, it appears that the preamorphization-induced defects influence strongly the response of the junction to an applied ac magnetic field.
Related Results
Analysis of magnetohydrodynamic drag character for hypersonic vehicles
Analysis of magnetohydrodynamic drag character for hypersonic vehicles
In hypersonic flight, a very high temperature area can form ahead of the nose of aerocraft due to the shock aerodynamic heating, which leads to air weakly ionized. Many researchers...
Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...
Electrical Active Defects in the Band-Gap Induced by Ge-Preamorphization of Si-Substrates
Electrical Active Defects in the Band-Gap Induced by Ge-Preamorphization of Si-Substrates
ABSTRACTUltra-shallow p+ -n junctions have been obtained from Ge+ -preamorphized and crystalline <100> silicon substrates. B+ and BF2+ dopants have been used. Boron was impla...
Organization of cell junctions in the peritoneal mesothelium
Organization of cell junctions in the peritoneal mesothelium
Intercellular junctions in the mesothelium of the visceral (mesentery and omentum), and parietal (diaphragm, pre-aortic, and iliac region) peritoneum were examined in rats and mice...
Modeling of Mechanism of Leakage in a Shallow p+/n Junction Formed by Preamorphization
Modeling of Mechanism of Leakage in a Shallow p+/n Junction Formed by Preamorphization
A model of the leakage induced by preamorphization is developed, assuming that the depth profile of excess interstitials making up dislocation loops is equal to the profile before ...
Tissue‐specific granularity of gap junction cytoplasmic surface revealed by rapid‐freeze, deep‐etch replicas
Tissue‐specific granularity of gap junction cytoplasmic surface revealed by rapid‐freeze, deep‐etch replicas
AbstractPrevious rapid‐freeze, deep‐etch replica studies have revealed the differences between heart and liver gap junctions; cytoplasmic surfaces of in situ and phenylmethylsulfno...
Spectral method for processing hydromagnetic survey data at shallow depths
Spectral method for processing hydromagnetic survey data at shallow depths
<p>Magnetic surveys are commonly used for solving variety of geotechnical and geological challenges in offshore areas, jointly with a set of other geophysical methods...
Cell Junctions in Periodontal Health and Disease: An Insight
Cell Junctions in Periodontal Health and Disease: An Insight
AbstractCells are the building blocks of all living organisms. The presence of cell junctions such as tight junctions, gap junctions, and anchoring junctions between cells play a r...

