Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

HOW RELIABLE IS THE AMOUNT OF INTERPROXIMAL REDUCTION CLINCHECK SOFTWARE RECOMMENDS?

View through CrossRef
Objective: This study was conducted to evaluate the reliability of Bolton analysis results obtained with ClinCheck software and the interproximal reduction (IPR) ratios the software recommends. Materials Methods: From the Invisalign® clear aligner system database, 120 individuals were divided into three groups according to Angle classification: dental class I (n=43), dental class II (n=49), and dental class III (n=28) malocclusions. The Bolton analysis data and the IPR amounts determined by Align Technology’s digital treatment planning interface, ClinCheck, were evaluated separately for the maxilla and mandible for each individual. A discrepancy was defined as the condition in which the Bolton ratio the software determined and the suggested IPR amount for the anterior ratio and the overall ratio exceeded 2 mm. The average anterior Bolton ratio and suggested anterior Bolton ratio, along with the total Bolton ratio and suggested total Bolton ratio for all individuals, were compared using Cronbach’s alpha. Results: It was determined that the average suggested anterior Bolton ratio for individuals with class I malocclusion was higher than that for individuals with other malocclusions (p=0.008). Cronbach’s alpha for the anterior Bolton ratio and the suggested anterior Bolton ratio was 0.131 whereas the overall ratio and the suggested overall Bolton ratio value were determined to be 0.41. Both values are defined as indicating weak reliability. Conclusion: A weak reliability relationship was detected between the Bolton values obtained with the ClinCheck software and the IPR suggestions provided in treatment planning.
Title: HOW RELIABLE IS THE AMOUNT OF INTERPROXIMAL REDUCTION CLINCHECK SOFTWARE RECOMMENDS?
Description:
Objective: This study was conducted to evaluate the reliability of Bolton analysis results obtained with ClinCheck software and the interproximal reduction (IPR) ratios the software recommends.
Materials Methods: From the Invisalign® clear aligner system database, 120 individuals were divided into three groups according to Angle classification: dental class I (n=43), dental class II (n=49), and dental class III (n=28) malocclusions.
The Bolton analysis data and the IPR amounts determined by Align Technology’s digital treatment planning interface, ClinCheck, were evaluated separately for the maxilla and mandible for each individual.
A discrepancy was defined as the condition in which the Bolton ratio the software determined and the suggested IPR amount for the anterior ratio and the overall ratio exceeded 2 mm.
The average anterior Bolton ratio and suggested anterior Bolton ratio, along with the total Bolton ratio and suggested total Bolton ratio for all individuals, were compared using Cronbach’s alpha.
Results: It was determined that the average suggested anterior Bolton ratio for individuals with class I malocclusion was higher than that for individuals with other malocclusions (p=0.
008).
Cronbach’s alpha for the anterior Bolton ratio and the suggested anterior Bolton ratio was 0.
131 whereas the overall ratio and the suggested overall Bolton ratio value were determined to be 0.
41.
Both values are defined as indicating weak reliability.
Conclusion: A weak reliability relationship was detected between the Bolton values obtained with the ClinCheck software and the IPR suggestions provided in treatment planning.

Related Results

Predictability of ClinCheck in Overbite Correction with Aligners: A Systematic Review
Predictability of ClinCheck in Overbite Correction with Aligners: A Systematic Review
Background: The use of aligner therapy for open bite and deep bite correction has increased in contemporary society. There is no evidence that unify the results present the in lite...
Periodontal Regeneration in Humans Using Recombinant Human Platelet‐ Derived Growth Factor‐BB (rhPDGF‐BB) and Allogenic Bone
Periodontal Regeneration in Humans Using Recombinant Human Platelet‐ Derived Growth Factor‐BB (rhPDGF‐BB) and Allogenic Bone
Background: Purified recombinant human platelet‐derived growth factor BB (rhPDGF‐BB) is a potent wound healing growth factor and stimulator of the proliferation and recruitment of ...
Clinical SWIR and CP-OCT imaging of interproximal lesions
Clinical SWIR and CP-OCT imaging of interproximal lesions
Abstract Background Enamel is highly transparent at short wavelength infrared imaging (SWIR) wavelengths allowing the detection of dental decay with...
Factors impacting the height of the interproximal papilla: A cross‐sectional study
Factors impacting the height of the interproximal papilla: A cross‐sectional study
Abstract Objectives To determine the relationship between different parameters (age, periodontal phenotype, contact point...
Short-term postorthodontic changes in the absence of retention
Short-term postorthodontic changes in the absence of retention
Abstract Objective: To evaluate short-term postorthodontic tooth movement without retention. Materials and Methods: ...
Clinical Management of Gingival Recessions with or Without Cervical Lesions: A Decisional Scheme Proposal
Clinical Management of Gingival Recessions with or Without Cervical Lesions: A Decisional Scheme Proposal
Background: Treatment of gingival recessions starts from an accurate diagnosis considering both periodontal tissue status and adjacent exposed dental tissues. Based on current scie...
Generative AI for Enterprise Software Engineering: Current Applications, Challenges, and Future Research Directions
Generative AI for Enterprise Software Engineering: Current Applications, Challenges, and Future Research Directions
Generative Artificial Intelligence (GenAI) and Large Language Models (LLMs) are revolutionizing <br> enterprise software engineering, meaning there is intelligent automation ...
Software Assurance
Software Assurance
Abstract Confidence in software quality is a rare commodity throughout all industries. Software publishers, users, and system integrators are highly distrustful of anyone...

Back to Top