Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Experimental Study of the Heat Flow and Energy Consumption during Liquid Cooling Due to Radiative Heat Transfer in Winter

View through CrossRef
Radiation cooling is a passive energy saving cooling technology. The process of cooling heat transfer liquid due to the combined effect of night radiative cooling and convection of air at negative temperatures (in winter) is studied. The radiator used for cooling was built into the roof of the building. Its radiating plate was made of a steel sheet coated with zinc oxide. In it, heat dissipation was carried out both from the upper and lower sides of the radiating plate. The experimental values of the heat flux ranged from 20 to 80 W·m−2 at a temperature difference between heat transfer liquid and air from 5 to 15 °C and ambient air temperature from −17 to +5 °C. The correctness of the model for calculating the heat flux in winter conditions was confirmed. A theoretical calculation showed that, in winter, the heat flux removed by the radiator will be 15% less than the heat flux in summer. The amount of heat transferred per watt of electrical power of the refrigeration unit reached 8 W·W−1. To keep the refrigeration unit with radiative heat transfer more efficient than in a conventional vapor compression chiller, the heat transfer liquid temperature should be 6 °C above the atmospheric temperature air. The results of the study show that radiative cooling can be used in winter and may be useful for the development of energy-efficient cooling systems for various purposes (air conditioning, industrial cooling systems and fruit storage chambers).
Title: Experimental Study of the Heat Flow and Energy Consumption during Liquid Cooling Due to Radiative Heat Transfer in Winter
Description:
Radiation cooling is a passive energy saving cooling technology.
The process of cooling heat transfer liquid due to the combined effect of night radiative cooling and convection of air at negative temperatures (in winter) is studied.
The radiator used for cooling was built into the roof of the building.
Its radiating plate was made of a steel sheet coated with zinc oxide.
In it, heat dissipation was carried out both from the upper and lower sides of the radiating plate.
The experimental values of the heat flux ranged from 20 to 80 W·m−2 at a temperature difference between heat transfer liquid and air from 5 to 15 °C and ambient air temperature from −17 to +5 °C.
The correctness of the model for calculating the heat flux in winter conditions was confirmed.
A theoretical calculation showed that, in winter, the heat flux removed by the radiator will be 15% less than the heat flux in summer.
The amount of heat transferred per watt of electrical power of the refrigeration unit reached 8 W·W−1.
To keep the refrigeration unit with radiative heat transfer more efficient than in a conventional vapor compression chiller, the heat transfer liquid temperature should be 6 °C above the atmospheric temperature air.
The results of the study show that radiative cooling can be used in winter and may be useful for the development of energy-efficient cooling systems for various purposes (air conditioning, industrial cooling systems and fruit storage chambers).

Related Results

Average Wall Radiative Heat Transfer Characteristic of Isothermal Radiative Medium in Inner Straight Fin Tubes
Average Wall Radiative Heat Transfer Characteristic of Isothermal Radiative Medium in Inner Straight Fin Tubes
Abstract Wall radiative heat transfer in inner straight fin tubes is very complex considering the coupling of heat conduction in fins and radiative heat transfer of ...
Film Cooling Calculations With an Iterative Conjugate Heat Transfer Approach Using Empirical Heat Transfer Coefficient Corrections
Film Cooling Calculations With an Iterative Conjugate Heat Transfer Approach Using Empirical Heat Transfer Coefficient Corrections
An iterative conjugate heat transfer technique has been developed to predict the temperatures on film cooled surfaces such as flat plates and turbine blades. Conventional approache...
Numerical calculation of passenger compartment cooling effect under the action of radiative cooling film based on MATLAB
Numerical calculation of passenger compartment cooling effect under the action of radiative cooling film based on MATLAB
Abstract Radiative cooling uses space cold source to cool the object, and the radiative cooling film made by using this principle can be applied to automobiles effec...
Large Eddy Simulations on Fan Shaped Film Cooling Hole With Various Inlet Turbulence Generation Methods
Large Eddy Simulations on Fan Shaped Film Cooling Hole With Various Inlet Turbulence Generation Methods
Abstract Large eddy simulations on well-known 7-7-7 fan shaped cooling hole have been carried out. Film cooling methods are generally applied to high pressure turbin...
Cooling capacity of experimental system with natural refrigerant circulation and condenser radiative cooling
Cooling capacity of experimental system with natural refrigerant circulation and condenser radiative cooling
The surface of the Earth is a source of radiation of thermal energy, which, passing through the atmosphere, is partially absorbed while the bulk of the energy is released into the ...
In-situ estimates of the role of radiative cooling for shallow convective organization
In-situ estimates of the role of radiative cooling for shallow convective organization
<p>This study investigates the role of radiative processes in shaping the spatial distribution of shallow clouds, using in-situ measurements retrieved during the EURE...
Enhancement of Film Cooling Effectiveness Using Dean Vortices
Enhancement of Film Cooling Effectiveness Using Dean Vortices
Abstract Film cooling technology is widely used in gas turbines. Improvement of gas turbine thermal efficiency, specific power and specific thrust can be achieved by...
Thermal energy storage with tunnels in different subsurface conditions
Thermal energy storage with tunnels in different subsurface conditions
The widespread use of the underground and global climate change impact the urban subsurface temperature. Changes in the subsurface environment can affect the performance of undergr...

Back to Top