Javascript must be enabled to continue!
Cooling capacity of experimental system with natural refrigerant circulation and condenser radiative cooling
View through CrossRef
The surface of the Earth is a source of radiation of thermal energy, which, passing through the atmosphere, is partially absorbed while the bulk of the energy is released into the surrounding outer space. A cooling technique based on this physical phenomenon is known as radiative cooling (RC). It is possible to reduce the consumption of electricity for cooling, as well as to reduce capital costs, by integrating the unit with radiative cooling directly into the circulation circuit of the refrigerant of the refrigeration machine. An experimental refrigeration system has been designed, in which in the cold periods of the year the removal of heat from the cooled object is carried out due to the mode of natural circulation of the refrigerant from the evaporator to the heat exchanger, cooled by radiative cooling. A refrigeration system with natural circulation and radiative cooling of the refrigerant R134a was experimentally studied during the autumn period in Almaty. The experimental study established that the chamber is cooled with the help of the examined system while the temperature in the cooled volume is maintained by 5...7 K above ambient air temperature at night. The dependence of the air temperature in the refrigerating chamber on the temperature of the atmospheric air has been determined. A procedure for assessing the cooling capacity of the system has been devised.
The study reported here demonstrated the possibility of using radiative cooling to remove heat under the mode of natural circulation of the refrigerant.
The refrigeration system reduces energy consumption in the cold seasons by diverting heat to the environment without the compressor operating
Private Company Technology Center
Title: Cooling capacity of experimental system with natural refrigerant circulation and condenser radiative cooling
Description:
The surface of the Earth is a source of radiation of thermal energy, which, passing through the atmosphere, is partially absorbed while the bulk of the energy is released into the surrounding outer space.
A cooling technique based on this physical phenomenon is known as radiative cooling (RC).
It is possible to reduce the consumption of electricity for cooling, as well as to reduce capital costs, by integrating the unit with radiative cooling directly into the circulation circuit of the refrigerant of the refrigeration machine.
An experimental refrigeration system has been designed, in which in the cold periods of the year the removal of heat from the cooled object is carried out due to the mode of natural circulation of the refrigerant from the evaporator to the heat exchanger, cooled by radiative cooling.
A refrigeration system with natural circulation and radiative cooling of the refrigerant R134a was experimentally studied during the autumn period in Almaty.
The experimental study established that the chamber is cooled with the help of the examined system while the temperature in the cooled volume is maintained by 5.
7 K above ambient air temperature at night.
The dependence of the air temperature in the refrigerating chamber on the temperature of the atmospheric air has been determined.
A procedure for assessing the cooling capacity of the system has been devised.
The study reported here demonstrated the possibility of using radiative cooling to remove heat under the mode of natural circulation of the refrigerant.
The refrigeration system reduces energy consumption in the cold seasons by diverting heat to the environment without the compressor operating.
Related Results
Air-Conditioning Using Waste Heat Energy
Air-Conditioning Using Waste Heat Energy
Abstract
All oil & gas building facilities such as control room, electrical room, substation and personal accommodation etc., require a comfortable indoor condit...
Condensation heat removal due to the combined impact of natural convection and radiative cooling
Condensation heat removal due to the combined impact of natural convection and radiative cooling
The work examines the heat exchange characteristics of a condenser in which heat removal of the refrigerant condensation occurs due to natural convection and radiation cooling. The...
In-situ estimates of the role of radiative cooling for shallow convective organization
In-situ estimates of the role of radiative cooling for shallow convective organization
<p>This study investigates the role of radiative processes in shaping the spatial distribution of shallow clouds, using in-situ measurements retrieved during the EURE...
Advanced Dual Refrigerant Expansion Cycle for Liquefaction
Advanced Dual Refrigerant Expansion Cycle for Liquefaction
Abstract
This paper presents a LNG Liquefaction cycle configuration using two stages of methane expansion and a single stage of nitrogen expansion (Dual Refrigerant)...
Numerical calculation of passenger compartment cooling effect under the action of radiative cooling film based on MATLAB
Numerical calculation of passenger compartment cooling effect under the action of radiative cooling film based on MATLAB
Abstract
Radiative cooling uses space cold source to cool the object, and the radiative cooling film made by using this principle can be applied to automobiles effec...
Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
The present work includes design, construction and operates of a prototype solar absorption refrigeration system, using methanol as a refrigerant to avoid any refrigerant that caus...
Advanced Liquefaction Cycle for Natural Gas
Advanced Liquefaction Cycle for Natural Gas
This paper presents a LNG Liquefaction cycle configuration using two stages of methane expansion and a single stage of nitrogen expansion (Dual Refrigerant) to improve the efficien...
Average Wall Radiative Heat Transfer Characteristic of Isothermal Radiative Medium in Inner Straight Fin Tubes
Average Wall Radiative Heat Transfer Characteristic of Isothermal Radiative Medium in Inner Straight Fin Tubes
Abstract
Wall radiative heat transfer in inner straight fin tubes is very complex considering the coupling of heat conduction in fins and radiative heat transfer of ...