Ristretto MRE: A generalized multi‐shot GRE‐MRE sequence

View through CrossRef
In order to acquire consistent k‐space data in MR elastography, a fixed temporal relationship between the MRI sequence and the underlying period of the wave needs to be ensured. To this end, conventional GRE‐MRE enforces synchronization through repeated triggering of the transducer and forcing the sequence repetition time to be equal to an integer multiple of the wave period. For wave frequencies below 100 Hz, however, this leads to prolonged acquisition times, as the repetition time scales inversely with frequency. A previously developed multi‐shot approach (eXpresso MRE) to multi‐slice GRE‐MRE tackles this issue by acquiring an integer number of slices per wave period, which allows acquisition to be accelerated in typical scenarios by a factor of two or three. In this work, it is demonstrated that the constraints imposed by the eXpresso scheme are overly restrictive. We propose a generalization of the sequence in three steps by incorporating sequence delays into imaging shots and allowing for interleaved wave‐phase acquisition. The Ristretto scheme is compared in terms of imaging shot and total scan duration relative to eXpresso and conventional GRE‐MRE and is validated in three different phantom studies. First, the agreement of measured displacement fields in different stages of the sequence generalization is shown. Second, performance is compared for 25, 36, 40, and 60 Hz actuation frequencies. Third, the performance is assessed for the acquisition of different numbers of slices (13 to 17). In vivo feasibility is demonstrated in the liver and the breast. Here, Ristretto is compared with an optimized eXpresso sequence, leading to scan accelerations of 15% and 5%, respectively, without compromising displacement field and stiffness estimates in general. The Ristretto concept allows us to choose imaging shot durations on a fine grid independent of the number of slices and the wave frequency, permitting 2‐ to 4.5‐fold acceleration of conventional GRE‐MRE acquisitions.
Title: Ristretto MRE: A generalized multi‐shot GRE‐MRE sequence
Description:
In order to acquire consistent k‐space data in MR elastography, a fixed temporal relationship between the MRI sequence and the underlying period of the wave needs to be ensured.
To this end, conventional GRE‐MRE enforces synchronization through repeated triggering of the transducer and forcing the sequence repetition time to be equal to an integer multiple of the wave period.
For wave frequencies below 100 Hz, however, this leads to prolonged acquisition times, as the repetition time scales inversely with frequency.
A previously developed multi‐shot approach (eXpresso MRE) to multi‐slice GRE‐MRE tackles this issue by acquiring an integer number of slices per wave period, which allows acquisition to be accelerated in typical scenarios by a factor of two or three.
In this work, it is demonstrated that the constraints imposed by the eXpresso scheme are overly restrictive.
We propose a generalization of the sequence in three steps by incorporating sequence delays into imaging shots and allowing for interleaved wave‐phase acquisition.
The Ristretto scheme is compared in terms of imaging shot and total scan duration relative to eXpresso and conventional GRE‐MRE and is validated in three different phantom studies.
First, the agreement of measured displacement fields in different stages of the sequence generalization is shown.
Second, performance is compared for 25, 36, 40, and 60 Hz actuation frequencies.
Third, the performance is assessed for the acquisition of different numbers of slices (13 to 17).
In vivo feasibility is demonstrated in the liver and the breast.
Here, Ristretto is compared with an optimized eXpresso sequence, leading to scan accelerations of 15% and 5%, respectively, without compromising displacement field and stiffness estimates in general.
The Ristretto concept allows us to choose imaging shot durations on a fine grid independent of the number of slices and the wave frequency, permitting 2‐ to 4.
5‐fold acceleration of conventional GRE‐MRE acquisitions.

Related Results

Magnetic Resonance Elastography of kidneys: SE‐EPI MRE reproducibility and its comparison to GRE MRE
Magnetic Resonance Elastography of kidneys: SE‐EPI MRE reproducibility and its comparison to GRE MRE
The purpose of this study is 1) to demonstrate reproducibility of spin echo‐echo planar imaging (SE‐EPI) magnetic resonance elastography (MRE) to estimate kidney stiffness; and 2) ...
Resection of DNA double strand breaks in the germline of Caenorhabditis elegans
Resection of DNA double strand breaks in the germline of Caenorhabditis elegans
<p>Repair of double-strand DNA breaks (DSBs) by the homologous recombination (HR) pathway results in crossovers (COs) required for a successful first meiotic division. DSB re...
FAKTOR-FAKTOR PENENTU KEPUTUSAN PEMBELIAN MELALUI E-COMMERCE PAD PT. GRE
FAKTOR-FAKTOR PENENTU KEPUTUSAN PEMBELIAN MELALUI E-COMMERCE PAD PT. GRE
This study aimed to determine the factors that influence purchasing decisions through e-commerce on PT. GRE. The reasearch was conducted to determine whether there is influence of ...
Risk factors for acquisition of multidrug-resistant Enterobacterales among international travellers: a synthesis of cumulative evidence
Risk factors for acquisition of multidrug-resistant Enterobacterales among international travellers: a synthesis of cumulative evidence
AbstractBackgroundRecent studies have shown that over 50% of people travelling to Southeast Asia return colonized with multidrug-resistant Enterobacterales (MRE) including carbapen...
Journey of GRE Pipelines Life Extension Testing and Challenges
Journey of GRE Pipelines Life Extension Testing and Challenges
Abstract Glass Reinforced Epoxy (GRE) pipes have been extensively used by Petroleum Development Oman (PDO) in pipeline application mainly for oil and water transport...
Abstract W P4: Prediction of Antegrade Flow Using FLAIR and GRE in Hyperacute Stroke
Abstract W P4: Prediction of Antegrade Flow Using FLAIR and GRE in Hyperacute Stroke
Background: Recanalization of an occluded vessel has been shown to improve clinical outcomes in hyperacute ischemic strokes. Presence of antegrade flow across the occlu...
Simultaneous multislice rapid magnetic resonance elastography of the liver
Simultaneous multislice rapid magnetic resonance elastography of the liver
To design and validate a rapid Simultaneous Multi‐slice (SMS) Magnetic Resonance Elastography technique (MRE), which combines SMS acquisition, in‐plane undersampling and an existin...