Javascript must be enabled to continue!
The pharmacokinetics of Biolimus A9 after elution from the Nobori stent in patients with coronary artery disease: The NOBORI PK study
View through CrossRef
AbstractObjectives:The aim of this study was to assess the pharmacokinetics and tolerability of Biolimus A9 eluted from Nobori coronary stents.Background:The release kinetics and pharmacokinetics of drugs delivered via coronary stents have been shown to play an essential role in the efficacy and safety of drug eluting stents.Methods:Twenty patients with coronary artery disease were treated with single 14‐mm (10 patients) or 28‐mm long stent (10 patients). Blood samples were drawn at 16 time points to determine the pharmacokinetics of Biolimus A9. At seven time points, complete laboratory and toxicology panels were assessed to screen for potential Biolimus A9 toxicity. The primary endpoint of the study was the systemic blood concentrations of Biolimus A9 after 28 days and 6 months as measured using highly specific and sensitive liquid chromatography‐ tandem mass spectrometry assay.Results:At 28 days, 6 patients (30%) had quantifiable Biolimus A9 concentrations in blood. The highest Biolimus A9 blood concentration measured in any sample was 32.2 pg/mL. The median time to maximum concentration was 2 hr, ranging from 0.05 hr to 3 months. Six months after stent implantation, only 1 of 20 patients had measurable Biolimus A9 concentrations at the lowest level of quantification, while at 9 months no sample had quantifiable Biolimus A9 concentrations. Laboratory and toxicology assessments did not indicate any impact of Biolimus A9 on the evaluated parameters.Conclusion:Results of this study suggest that systemic exposure to Biolimus A9 was very low and that Biolimus A9 was well tolerated. © 2008 Wiley‐Liss, Inc.
Wiley
Title: The pharmacokinetics of Biolimus A9 after elution from the Nobori stent in patients with coronary artery disease: The NOBORI PK study
Description:
AbstractObjectives:The aim of this study was to assess the pharmacokinetics and tolerability of Biolimus A9 eluted from Nobori coronary stents.
Background:The release kinetics and pharmacokinetics of drugs delivered via coronary stents have been shown to play an essential role in the efficacy and safety of drug eluting stents.
Methods:Twenty patients with coronary artery disease were treated with single 14‐mm (10 patients) or 28‐mm long stent (10 patients).
Blood samples were drawn at 16 time points to determine the pharmacokinetics of Biolimus A9.
At seven time points, complete laboratory and toxicology panels were assessed to screen for potential Biolimus A9 toxicity.
The primary endpoint of the study was the systemic blood concentrations of Biolimus A9 after 28 days and 6 months as measured using highly specific and sensitive liquid chromatography‐ tandem mass spectrometry assay.
Results:At 28 days, 6 patients (30%) had quantifiable Biolimus A9 concentrations in blood.
The highest Biolimus A9 blood concentration measured in any sample was 32.
2 pg/mL.
The median time to maximum concentration was 2 hr, ranging from 0.
05 hr to 3 months.
Six months after stent implantation, only 1 of 20 patients had measurable Biolimus A9 concentrations at the lowest level of quantification, while at 9 months no sample had quantifiable Biolimus A9 concentrations.
Laboratory and toxicology assessments did not indicate any impact of Biolimus A9 on the evaluated parameters.
Conclusion:Results of this study suggest that systemic exposure to Biolimus A9 was very low and that Biolimus A9 was well tolerated.
© 2008 Wiley‐Liss, Inc.
Related Results
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract
Introduction
Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract
Introduction
Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
e0543 Clinical and coronary angiography characteristics between young (<45) and old (>60) patients with coronary artery disease
e0543 Clinical and coronary angiography characteristics between young (<45) and old (>60) patients with coronary artery disease
Objective
To study the clinical Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease.
...
e0425 Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease
e0425 Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease
Objective
To study the clinical Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease.
...
A study on risk factors of coronary artery disease in Chong Qing city
A study on risk factors of coronary artery disease in Chong Qing city
Objective
To investigate the relationship between risk factors and coronary artery disease in Chong Qing city, and to provide scientific basis for preventing and ...
CLINICAL APPLICATION OF DOMESTIC LONG BIODEGRADABLE POLYMER COATED SIROLIMUS ELUTING STENTS FOR TREATMENT OF LONG CORONARY ARTERY LESIONS
CLINICAL APPLICATION OF DOMESTIC LONG BIODEGRADABLE POLYMER COATED SIROLIMUS ELUTING STENTS FOR TREATMENT OF LONG CORONARY ARTERY LESIONS
Objectives
To evaluate the efficacy and safety of domestic long biodegradable polymer coated sirolimus eluting stents (Excel stent, Shandong JW) for treatment of ...
Novel functionalized and patterned surfaces for cardiovascular applications
Novel functionalized and patterned surfaces for cardiovascular applications
Nowadays, cardiovascular diseases are mainly treated by implantation of a metallic or polymeric mesh, called stent, which maintains the artery widely open. This technique shows ver...
Navigating triple therapy in a high-risk cardiac patient with a covered stent and embolic stroke: A case report
Navigating triple therapy in a high-risk cardiac patient with a covered stent and embolic stroke: A case report
Abstract
Introduction: Covered stents such as the newly emerging FDA approved papyrus stent plays a pertinent role in th...

