The aim of the research was to develop a technique that improves the results of surgical treatment of dislocations of the femoral head component of the hip endoprosthesis.Materials and methods: The study included 64 patients who suffered from head dislocation after hip arthroplasty. For the treatment of patients of the first group, a technique was used in which the installation and fixation of the anti-luxation ring (“visor”) was performed screws to the existing cup or polyethylene insert of the endoprosthesis, which leads to the closure of the spherical head of the endoprosthesis in the pelvic component, which makes it impossible to separate them, thereby preventing dislocation of the endoprosthesis head for a long time. Patients of the second group were treated with other surgical methods.Results and conclusion: Patients of the two groups were followed up for 24 months after the revision surgery. In the first group (26 patients), 2 cases of complications occurred – relapse of dislocation (7.7%). In the second group(38 patients), repeated dislocation occurred in 6 (15.8%); in one case, fubular neuritis occurred.The developed technology, in which the device is fixed to the already installed parts of the endoprosthesis, will avoid a larger volume of surgery associated with the removal of well-fixed components of the endoprosthesis. If the surgeon, during a revision operation associated with dislocation of the head of the endoprosthesis, considers it possible to preserve the stably fixed components of the endoprosthesis, the method of choice may be the use of the proposed anti-luxation device.
Pirogov National Medical and Surgical Center
Title: SURGICAL TREATMENT OF DISLOCATION FOLLOWING TOTAL HIP REPLACEMENT
Description:
The aim of the research was to develop a technique that improves the results of surgical treatment of dislocations of the femoral head component of the hip endoprosthesis.
Materials and methods: The study included 64 patients who suffered from head dislocation after hip arthroplasty.
For the treatment of patients of the first group, a technique was used in which the installation and fixation of the anti-luxation ring (“visor”) was performed screws to the existing cup or polyethylene insert of the endoprosthesis, which leads to the closure of the spherical head of the endoprosthesis in the pelvic component, which makes it impossible to separate them, thereby preventing dislocation of the endoprosthesis head for a long time.
Patients of the second group were treated with other surgical methods.
Results and conclusion: Patients of the two groups were followed up for 24 months after the revision surgery.
In the first group (26 patients), 2 cases of complications occurred – relapse of dislocation (7.
7%).
In the second group(38 patients), repeated dislocation occurred in 6 (15.
8%); in one case, fubular neuritis occurred.
The developed technology, in which the device is fixed to the already installed parts of the endoprosthesis, will avoid a larger volume of surgery associated with the removal of well-fixed components of the endoprosthesis.
If the surgeon, during a revision operation associated with dislocation of the head of the endoprosthesis, considers it possible to preserve the stably fixed components of the endoprosthesis, the method of choice may be the use of the proposed anti-luxation device.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Running is a popular form of exercise that is accompanied by many health benefits. However, running also comes with a risk of overuse injuries. Women have a higher risk for overuse...
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
This paper explores South African hip-hop activist Emile YX?'s work to suggest that he presents an alternative take on mainstream US and South African hip-hop. While it is arguable...
Association of Hip Radiograph Findings With Pain and Function in Patients Presenting With Low Back Pain
Association of Hip Radiograph Findings With Pain and Function in Patients Presenting With Low Back Pain
AbstractBackgroundRelationships between low back pain (LBP) and the hip in patient cohorts have been described primarily in patients with moderate to severe hip osteoarthritis (OA)...
Bilateral Traumatic Posterior Hip Dislocation – A Case Report
Bilateral Traumatic Posterior Hip Dislocation – A Case Report
Introduction: Although posterior dislocation of the hip is common, bilateral posterior hip dislocation in children is an infrequent presentation. Early diagnosis and treatment are ...
Neglected hip fracture dislocation in young adult treated with total hip arthroplasty and bone graft
Neglected hip fracture dislocation in young adult treated with total hip arthroplasty and bone graft
Background: Hip fractures is estimated to occur in 176/100.000 population in Indonesia. Inadequate treatment or over negligence of hip fractures will result in significant morbidit...
No Difference in Hip Muscle Volumes and Fatty Infiltration in Those With Hip-Related Pain Compared to Controls
No Difference in Hip Muscle Volumes and Fatty Infiltration in Those With Hip-Related Pain Compared to Controls
Background
Little is known about muscle morphology in people with hip-related pain, without signs of femoro-acetabular impingement syndrome (FAIS). Identifying ...
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
Abstract
Despite advancements in fracture prediction tools and osteoporosis management, hip fractures remain a significant consequence of bone fr...