Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Effects of GFRP Stirrup Spacing on the Behavior of Doubly GFRP-Reinforced Concrete Beams

View through CrossRef
This study investigates the impact of varying glass fiber-reinforced polymer (GFRP) stirrup spacing on the performance of doubly GFRP-reinforced concrete beams. The research focuses on assessing the behavior of GFRP-reinforced concrete beams, including load-carrying capacity, cracking, and deformability. It explores the feasibility and effectiveness of GFRP bars as an alternative to traditional steel reinforcement in concrete structures. Six concrete beams with a cross-section of 300 mm (wide) × 250 mm (deep), simply supported on a 2100 mm span, were tested. The beams underwent four-point bending with two concentrated loads applied symmetrically at one-third of the span length, resulting in a shear span (a)-to-depth (h) ratio of 2.8. The experimental findings reveal that altering the GFRP stirrup spacing along the longitudinal axis of the beams, from 200 mm (equivalent to the effective depth (d)) to 50 mm (equal to (d⁄4)), altered the mode of failure from flexure-shear to flexure-compression. However, when the spacing was equal to or less than (d⁄3), there was no significant improvement in load-carrying capacity, as the contribution of GFRP bars in resisting shear loads was limited. Under service loads, the GFRP-reinforced beams exhibited wider cracks, but reducing the stirrup spacing helped restrain crack widening. Incorporating GFRP bars in the compression zone had a positive effect on reducing crack width in the tension zone. Additionally, using GFRP stirrups with spacing varying between (d) and (d⁄2) in the pure bending region increased the deflection ductility indexes. To enhance the ductility of GFRP-reinforced concrete beams, it is recommended to use GFRP stirrups in the pure bending region with spacing greater than the spacing between GFRP stirrups in the shear spans. The study highlights that the current ACI code overestimates the shear capacity provided by GFRP stirrups, particularly when the spacing is less than or equal to (d⁄3). Doi: 10.28991/CEJ-2024-010-02-011 Full Text: PDF
Title: Effects of GFRP Stirrup Spacing on the Behavior of Doubly GFRP-Reinforced Concrete Beams
Description:
This study investigates the impact of varying glass fiber-reinforced polymer (GFRP) stirrup spacing on the performance of doubly GFRP-reinforced concrete beams.
The research focuses on assessing the behavior of GFRP-reinforced concrete beams, including load-carrying capacity, cracking, and deformability.
It explores the feasibility and effectiveness of GFRP bars as an alternative to traditional steel reinforcement in concrete structures.
Six concrete beams with a cross-section of 300 mm (wide) × 250 mm (deep), simply supported on a 2100 mm span, were tested.
The beams underwent four-point bending with two concentrated loads applied symmetrically at one-third of the span length, resulting in a shear span (a)-to-depth (h) ratio of 2.
8.
The experimental findings reveal that altering the GFRP stirrup spacing along the longitudinal axis of the beams, from 200 mm (equivalent to the effective depth (d)) to 50 mm (equal to (d⁄4)), altered the mode of failure from flexure-shear to flexure-compression.
However, when the spacing was equal to or less than (d⁄3), there was no significant improvement in load-carrying capacity, as the contribution of GFRP bars in resisting shear loads was limited.
Under service loads, the GFRP-reinforced beams exhibited wider cracks, but reducing the stirrup spacing helped restrain crack widening.
Incorporating GFRP bars in the compression zone had a positive effect on reducing crack width in the tension zone.
Additionally, using GFRP stirrups with spacing varying between (d) and (d⁄2) in the pure bending region increased the deflection ductility indexes.
To enhance the ductility of GFRP-reinforced concrete beams, it is recommended to use GFRP stirrups in the pure bending region with spacing greater than the spacing between GFRP stirrups in the shear spans.
The study highlights that the current ACI code overestimates the shear capacity provided by GFRP stirrups, particularly when the spacing is less than or equal to (d⁄3).
 Doi: 10.
28991/CEJ-2024-010-02-011 Full Text: PDF.

Related Results

Flexural and Shear Behavior of Beams Reinforced with GFRP Rebars
Flexural and Shear Behavior of Beams Reinforced with GFRP Rebars
A new inexperienced constructing material is glass fibre reinforced polymer (GFRP) rebar. GFRP rebars are non-corrosive, non-conductive, light-weight substances and have an excessi...
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
The Effect of Compression Reinforcement on the Shear Behavior of Concrete Beams with Hybrid Reinforcement
The Effect of Compression Reinforcement on the Shear Behavior of Concrete Beams with Hybrid Reinforcement
Abstract This study examines the impact of steel compression reinforcement on the shear behavior of concrete beams reinforced with glass fiber reinforced polymer (GFRP) bar...
Performance of doubly reinforced concrete beams with GFRP bars
Performance of doubly reinforced concrete beams with GFRP bars
Abstract The study focused on examining the behavior of six concrete beams that were reinforced with glass fiber-reinforced polymer (GFRP) bars to evaluate their ...
Service Load Behavior of Hybrid UHPC T-Beams Reinforced with GFRP Bars
Service Load Behavior of Hybrid UHPC T-Beams Reinforced with GFRP Bars
Six hybrid Tee beams reinforced with GFRP were the subject of an experimental study in this article, the main parameters that were investigated were different reinforcement ratios ...
Experimental and Numerical Investigation of Flexural Behaviour of GFRP Reinforced Concrete Beams using ANSYS
Experimental and Numerical Investigation of Flexural Behaviour of GFRP Reinforced Concrete Beams using ANSYS
Abstract The construction industry has made extensive use of glass fiber-reinforced polymer (GFRP) rebars to improve structural strength and stop corrosion. High tensile st...
Study of Flexural Behavior of High Strength Concrete Beams Reinforced with GFRP Bars
Study of Flexural Behavior of High Strength Concrete Beams Reinforced with GFRP Bars
This paper presents the test results of an experimental program which consisted of 8 beams with 100 x 200 mm cross-sectional dimensions.  The beams were tested under four-point loa...

Back to Top