Javascript must be enabled to continue!
CONVEX: Consensus Variant Pipeline for Exome Analysis
View through CrossRef
Benchmarking whole exome pipelines is crucial for evaluating and comparing their performance in variant calling and clinical significance annotation. It enables researchers and clinicians to assess the accuracy, sensitivity, and specificity of different pipelines and identify the most effective and reliable ones. In this study, we evaluated and compared the performance of our in-house consensus exome pipeline with a widely recognized gold standard Genome Analysis Toolkit (GATK) pipeline. Four datasets were used for evaluation, three 1000 Genome Project (1KGP) datasets and one Prostate cancer (PCa) Sample. The consensus pipeline consistently demonstrated a higher average transition-to-transversion (Ti/Tv) ratio, indicating enhanced precision in identifying single nucleotide variant (SNV) calls. This suggests that the consensus pipeline excels in effectively discerning true genetic variations from sequencing artefacts, particularly in the context of exome sequencing. Additionally, the pipeline exhibited increased sensitivity in detecting pathogenic and likely pathogenic variants in the PCa sample, further highlighting its efficacy in identifying clinically relevant variants. We also conducted a trio exome analysis with the use of two trio pipelines, viz. VarScan Trio and GATK joint calling pipelines on our erstwhile Congenital Pouch Colon (CPC) samples from our rare disease cohort which we published earlier and found that the GATK predicted a significantly higher number of variants compared to VarScan. From our pipeline, viz. CONVEX: Consensus Variant Pipeline for Exome Analysis we developed, our study demonstrates a large potential for trio-variant calling analysis paving the way for precision medicine. We discuss the impending benchmark results using the CONVEX.
Title: CONVEX: Consensus Variant Pipeline for Exome Analysis
Description:
Benchmarking whole exome pipelines is crucial for evaluating and comparing their performance in variant calling and clinical significance annotation.
It enables researchers and clinicians to assess the accuracy, sensitivity, and specificity of different pipelines and identify the most effective and reliable ones.
In this study, we evaluated and compared the performance of our in-house consensus exome pipeline with a widely recognized gold standard Genome Analysis Toolkit (GATK) pipeline.
Four datasets were used for evaluation, three 1000 Genome Project (1KGP) datasets and one Prostate cancer (PCa) Sample.
The consensus pipeline consistently demonstrated a higher average transition-to-transversion (Ti/Tv) ratio, indicating enhanced precision in identifying single nucleotide variant (SNV) calls.
This suggests that the consensus pipeline excels in effectively discerning true genetic variations from sequencing artefacts, particularly in the context of exome sequencing.
Additionally, the pipeline exhibited increased sensitivity in detecting pathogenic and likely pathogenic variants in the PCa sample, further highlighting its efficacy in identifying clinically relevant variants.
We also conducted a trio exome analysis with the use of two trio pipelines, viz.
VarScan Trio and GATK joint calling pipelines on our erstwhile Congenital Pouch Colon (CPC) samples from our rare disease cohort which we published earlier and found that the GATK predicted a significantly higher number of variants compared to VarScan.
From our pipeline, viz.
CONVEX: Consensus Variant Pipeline for Exome Analysis we developed, our study demonstrates a large potential for trio-variant calling analysis paving the way for precision medicine.
We discuss the impending benchmark results using the CONVEX.
Related Results
Ostrowski-Type Fractional Integral Inequalities: A Survey
Ostrowski-Type Fractional Integral Inequalities: A Survey
This paper presents an extensive review of some recent results on fractional Ostrowski-type inequalities associated with a variety of convexities and different kinds of fractional ...
Installation Analysis of Matterhorn Pipeline Replacement
Installation Analysis of Matterhorn Pipeline Replacement
Abstract
The paper describes the installation analysis for the Matterhorn field pipeline replacement, located in water depths between 800-ft to 1200-ft in the Gul...
First Arctic Subsea Pipelines Moving to Reality
First Arctic Subsea Pipelines Moving to Reality
Abstract
Two offshore development projects which involve subsea arctic pipelines are being proposed by British Petroleum Exploration (BP). Both projects are locat...
Sleep Habits and Occurrence of Lowback Pain among Craftsmen
Sleep Habits and Occurrence of Lowback Pain among Craftsmen
<span style="color: #000000; font-family: Verdana, Arial, Helvetica, sans-serif; font-size: 10px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; ...
Sleep Habits and Occurrence of Lowback Pain among Craftsmen
Sleep Habits and Occurrence of Lowback Pain among Craftsmen
<span style="color: #000000; font-family: Verdana, Arial, Helvetica, sans-serif; font-size: 10px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; ...
Benchmarking whole exome sequencing pipeline for predicting pathogenic variants of significance
Benchmarking whole exome sequencing pipeline for predicting pathogenic variants of significance
Abstract
Benchmarking whole exome pipelines is crucial for evaluating and comparing their performance in variant calling and clinical significance annotation. It enables re...
Pilarowski–Bjornsson Syndrome with Congenital Heart Defect: A Case Report and Literature Review
Pilarowski–Bjornsson Syndrome with Congenital Heart Defect: A Case Report and Literature Review
Abstract
Introduction
Pilarowski–Bjornsson syndrome (PILBOS) is a rare autosomal dominant neurodevelopmental disorder caused by heterozygous variants in chromodomain helicase DNA-b...
Development and Use of Simulation Trainers for Pipeline Controllers
Development and Use of Simulation Trainers for Pipeline Controllers
Enbridge is in the forefront of development and application of computer simulation based training systems for Pipeline Controllers. Since 1985, the Pipeline Dynamics section of Enb...

