Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Age dependent normal horizontal VOR gain of head impulse test as measured with video-oculography

View through CrossRef
Background The head impulse test (HIT) is a recognised clinical sign of the high frequency vestibulo-ocular reflex (VOR), which can be quantified with video-oculography. This measures the VOR gain as the ratio of angular eye velocity to angular head velocity. Although normative data is available for VOR gain with video-oculography, most normal studies in general include small numbers of subjects and do not include analysis of variation of VOR gain with age. The purpose of our study was to establish normative data across 60 control subjects aged 20 to 80 years to represent a population distribution. Methods Sixty control subjects without any current or previous form of brain disorder or vertigo participated in this study and form the basis for future comparison to patients with vestibular lesions. The relationship between the horizontal vestibulo-ocular reflex (HVOR) velocity gain and age was analysed using a mixed regression model with a random effect for subjects. Differences in testing technique were assessed to ensure reliability in results. Results The mean HVOR velocity gain of 60 normal subjects was 0.97 (SD = 0.09) at 80 ms and 0.94 (SD = 0.10) at 60 ms. The 2 SD lower limit of normal HVOR velocity gain was 0.79 at 80 ms and 0.75 at 60 ms. No HVOR velocity gain fell below 0.76 and 0.65 at 80 ms and 60 ms respectively. The HVOR velocity gain declined by 0.012 and 0.017 per decade as age increased at 80 ms and 60 ms respectively. A non-physiologically high horizontal HVOR velocity gain was found to occur in tests where passive HITs were predictable in direction and time and where target distance was below 0.70 m. Conclusions Normative data with respect to HVOR velocity gain decreases slightly with age, but with careful attention to methodology the 2 SD lower limit of normal is relatively robust across a wide age range and into the eighth decade, without requirement for adjustment with age.
Title: Age dependent normal horizontal VOR gain of head impulse test as measured with video-oculography
Description:
Background The head impulse test (HIT) is a recognised clinical sign of the high frequency vestibulo-ocular reflex (VOR), which can be quantified with video-oculography.
This measures the VOR gain as the ratio of angular eye velocity to angular head velocity.
Although normative data is available for VOR gain with video-oculography, most normal studies in general include small numbers of subjects and do not include analysis of variation of VOR gain with age.
The purpose of our study was to establish normative data across 60 control subjects aged 20 to 80 years to represent a population distribution.
Methods Sixty control subjects without any current or previous form of brain disorder or vertigo participated in this study and form the basis for future comparison to patients with vestibular lesions.
The relationship between the horizontal vestibulo-ocular reflex (HVOR) velocity gain and age was analysed using a mixed regression model with a random effect for subjects.
Differences in testing technique were assessed to ensure reliability in results.
Results The mean HVOR velocity gain of 60 normal subjects was 0.
97 (SD = 0.
09) at 80 ms and 0.
94 (SD = 0.
10) at 60 ms.
The 2 SD lower limit of normal HVOR velocity gain was 0.
79 at 80 ms and 0.
75 at 60 ms.
No HVOR velocity gain fell below 0.
76 and 0.
65 at 80 ms and 60 ms respectively.
The HVOR velocity gain declined by 0.
012 and 0.
017 per decade as age increased at 80 ms and 60 ms respectively.
A non-physiologically high horizontal HVOR velocity gain was found to occur in tests where passive HITs were predictable in direction and time and where target distance was below 0.
70 m.
Conclusions Normative data with respect to HVOR velocity gain decreases slightly with age, but with careful attention to methodology the 2 SD lower limit of normal is relatively robust across a wide age range and into the eighth decade, without requirement for adjustment with age.

Related Results

On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
<span style="font-size:11pt"><span style="background:#f9f9f4"><span style="line-height:normal"><span style="font-family:Calibri,sans-serif"><b><spa...
A New Completion Technology to Improve Horizontal Well Performances
A New Completion Technology to Improve Horizontal Well Performances
Abstract Some recent research results have shown that especially for long horizontal wells with relatively high rate, when the friction loss plays a significant r...
Survey Of Horizontal Gas Well Activity
Survey Of Horizontal Gas Well Activity
Abstract This paper presents the results of a survey on horizontal gas well activity throughout the world. The survey was conducted for the Gas Research Institute...
Pressure Transient Analysis for Horizontal Well and Multi-Branched Horizontal Wells
Pressure Transient Analysis for Horizontal Well and Multi-Branched Horizontal Wells
Abstract Transient pressure for cases of a horizontal wellbore axis with any angle inclined to a fault or a constant pressure supply boundary in anisotropic forma...
Models de distribució sobre el símplex
Models de distribució sobre el símplex
Les dades composicionals són vectors les components dels quals representen proporcions respecte d'un total, i per tant estan sotmesos a la restricció que la suma de les seves compo...
Audiological and Vestibular Measurements in Chronic Renal Failure Patients Receiving Hemodialysis Treatment
Audiological and Vestibular Measurements in Chronic Renal Failure Patients Receiving Hemodialysis Treatment
BACKGROUND: The aim was to evaluate the changes in the audiovestibular system in adult patients with the diagnosis of chronic renal failure who were treated with hemodialysis. MET...
Physical Modelling of Recovery Processes Utilizing Horizontal Wells-Impact of Scaling Well Size
Physical Modelling of Recovery Processes Utilizing Horizontal Wells-Impact of Scaling Well Size
Abstract One of the main characteristics of horizontal wells is their extended contact with the reservoir. This extended contact provides many benefits for horizo...
Anisotropic Permeability Estimation by Horizontal Well Tests
Anisotropic Permeability Estimation by Horizontal Well Tests
Abstract A horizontal well drilled along the principal permeability kx direction is often assumed in horizontal well test interpretation. However, the orientation...

Back to Top