Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Development of Enhanced Test Methods to Evaluate Alkalisilica Reaction in Concrete

View through CrossRef
<p>Many preventive measures showed improved performance of concrete against alkali-silica reaction (ASR) based on the concrete prism test (CPT) described in the Canadian and American Standards, CSA A23.2-14A and ASTM C1293. However, research has shown that preventive measures that limited the 2-year expansion in the concrete prism test produced late expansion after 7-15 years when tested in the field. The objective of this research is to understand the possible reasons for this late expansion under field conditions and to come up with modified approach to determine the level of supplementary cementing materials (SCM) needed to mitigate the long-term expansion. The research mainly focuses on studying two possible reasons to explain the late expansion. The first reason is the rate and ultimate hydration of SCM, where their capacity to bind alkalis under CPT could be higher than those under field conditions. The other reason for the late expansion could be the geometry and size of the CPT samples which might reduce the expansion due to the excessive alkali leaching. Larger samples showed less leaching compared to standard prisms. 100-mm cylinders showed higher expansion than 75-mm standard prisms; however, both sample shapes showed similar expansions for one tested aggregate when used with SCM. In addition, the capacity of SCM to bind alkalis was shown to be higher at 38ºC compared to the other two tested temperatures investigated in this study: 23ºC and 60ºC. Samples with SCM at high replacement levels expanded more at 60ºC compared to 38ºC. Due to their reduced leaching compared to prisms, testing cylinders at 60ºC showed accelerated results reducing the testing duration to one year compared to the standard test duration of two years. Moreover, a new way to predict the minimum levels of SCM required to mitigate expansion due to alkali-silica reaction is presented showing better correlation with the field. Finally, a fast and reliable test method is suggested to evaluate the reactivity of mineral fillers by adapting and adopting the current test methods available for ASR testing.</p>
Ryerson University Library and Archives
Title: Development of Enhanced Test Methods to Evaluate Alkalisilica Reaction in Concrete
Description:
<p>Many preventive measures showed improved performance of concrete against alkali-silica reaction (ASR) based on the concrete prism test (CPT) described in the Canadian and American Standards, CSA A23.
2-14A and ASTM C1293.
However, research has shown that preventive measures that limited the 2-year expansion in the concrete prism test produced late expansion after 7-15 years when tested in the field.
The objective of this research is to understand the possible reasons for this late expansion under field conditions and to come up with modified approach to determine the level of supplementary cementing materials (SCM) needed to mitigate the long-term expansion.
The research mainly focuses on studying two possible reasons to explain the late expansion.
The first reason is the rate and ultimate hydration of SCM, where their capacity to bind alkalis under CPT could be higher than those under field conditions.
The other reason for the late expansion could be the geometry and size of the CPT samples which might reduce the expansion due to the excessive alkali leaching.
Larger samples showed less leaching compared to standard prisms.
100-mm cylinders showed higher expansion than 75-mm standard prisms; however, both sample shapes showed similar expansions for one tested aggregate when used with SCM.
In addition, the capacity of SCM to bind alkalis was shown to be higher at 38ºC compared to the other two tested temperatures investigated in this study: 23ºC and 60ºC.
Samples with SCM at high replacement levels expanded more at 60ºC compared to 38ºC.
Due to their reduced leaching compared to prisms, testing cylinders at 60ºC showed accelerated results reducing the testing duration to one year compared to the standard test duration of two years.
Moreover, a new way to predict the minimum levels of SCM required to mitigate expansion due to alkali-silica reaction is presented showing better correlation with the field.
Finally, a fast and reliable test method is suggested to evaluate the reactivity of mineral fillers by adapting and adopting the current test methods available for ASR testing.
</p>.

Related Results

Effect of different clay additions to concrete on its ultrasonic acoustic parameters and compressive strength
Effect of different clay additions to concrete on its ultrasonic acoustic parameters and compressive strength
Abstract Concrete may have different levels of mud content due to various factors, which can lead to reduction in strength and changes in ultrasonic acoustic parameters. In...
Experimental study on the influence of high-frequency vibratory mixing on concrete performance
Experimental study on the influence of high-frequency vibratory mixing on concrete performance
Abstract The method and parameter of mixing are crucial to the quality of concrete, and ordinary vibratory mixing is beneficial to the performance of concrete, which...
Perilaku Beton Porous Dengan Penambahan Zat Aditif Superplastizer (Sika Viscocrete)
Perilaku Beton Porous Dengan Penambahan Zat Aditif Superplastizer (Sika Viscocrete)
ABSTRACT According to ACI 522R-10, Larvious Concrete, or Pervious Concrete is defined as concrete that has a slump value almost close to zero, which is formed from Portland cement,...
Prilaku Kuat Tekan Beton Porous Menggunakan Air Laut
Prilaku Kuat Tekan Beton Porous Menggunakan Air Laut
Porous concrete has high porosity so that water can pass through the cavities in the concrete. The application of porous concrete is usually for parking areas, pedestrian sidewalks...
<i>In Situ</i> Inspection of Ultra Durable Concrete Using Electrical Resistivity Technique
<i>In Situ</i> Inspection of Ultra Durable Concrete Using Electrical Resistivity Technique
In today’s rapid construction, a reliable method for quick evaluation of concrete quality during construction is very important. The compressive strength of concrete has been used ...
Investigating the Effect of Steel Wire and Carbon Black from Worn Out Tyre on the Strength of Concrete
Investigating the Effect of Steel Wire and Carbon Black from Worn Out Tyre on the Strength of Concrete
Technology in concrete is rapidly developing to improve the quality and properties of concrete. One of the many recycled materials is worn-out tyres. Currently, the use of tires is...
Structural Behavior And Design Method Of Steel/Concrete Composite Ice Walls for Arctic Offshore Structures
Structural Behavior And Design Method Of Steel/Concrete Composite Ice Walls for Arctic Offshore Structures
ABSTRACT In order to develop an optimum steel/concrete composite ice wall for the arctic offshore structures, structural behavior of the steel/concrete composite ...
Development of Enhanced Test Methods to Evaluate Alkalisilica Reaction in Concrete
Development of Enhanced Test Methods to Evaluate Alkalisilica Reaction in Concrete
<p>Many preventive measures showed improved performance of concrete against alkali-silica reaction (ASR) based on the concrete prism test (CPT) described in the Canadian and ...

Back to Top