Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Multisite pacing upgrade for refractory heart failure in dual-chamber pacemaker recipients: a single-center experience of 71 cases

View through CrossRef
Abstract Background Prolonged right ventricular (RV) pacing in dual-chamber pacemaker recipients can induce electrical and mechanical dyssynchrony, leading to pacing-induced cardiomyopathy, compromised systolic function, and symptoms of heart failure (HF). The upgrade to Multisite Pacing (MSP), or Cardiac Resynchronization Therapy, is a physiological approach aimed at restoring cardiac synchrony and optimizing hemodynamic performance. Studies demonstrate its potential to improve ejection fraction and functional status. Objective This study evaluates the clinical and hemodynamic outcomes of a cohort of patients who underwent an upgrade from a dual-chamber pacemaker to Multisite Pacing at a specialized center. Methods Between March 2006 and October 2025, 914 MSP devices were implanted at our service. This analysis focused on 71 patients who were upgraded from a dual-chamber pacemaker to MSP due to a widened QRS complex secondary to chronic RV apical pacing, ventricular dyssynchrony, and persistent HF symptoms despite optimized medical therapy. The procedure involved coronary sinus cannulation via the femoral vein and left subclavian vein punctures for lead insertion, followed by venography to optimize the left ventricular lead position. Device programming targeted the shortest possible QRS interval. Patient characteristics and post-upgrade follow-up data, particularly regarding ejection fraction (EF), were collected. Results The 71 upgraded patients represented 7.8% of the total MSP implantations. The mean age was 60.5 years (range 45 to 76 years), and 64.8% were male. Underlying etiologies included Chagas Disease (47.9%), Coronary Artery Disease (22.5%), and Valvular Heart Disease (11.3%). The overall technical and clinical success rate for the upgrade procedure was 77.5%. Notably, there were no reported complications during or after the procedure. Of the patients, 77.5% received a system associated with an Implantable Cardioverter-Defibrillator (CRT-D). In 52 patients, there was a significant increase in Ejection Fraction (EF) of 73.2% after 12 months of follow-up. Conclusion The upgrade from a dual-chamber pacemaker to Multisite Pacing is an effective and safe intervention, demonstrating a high success rate and a clinically significant improvement in Ejection Fraction (73.2%) in patients with pacing-induced dyssynchrony and refractory heart failure, confirming relevant hemodynamic and functional benefits.
Title: Multisite pacing upgrade for refractory heart failure in dual-chamber pacemaker recipients: a single-center experience of 71 cases
Description:
Abstract Background Prolonged right ventricular (RV) pacing in dual-chamber pacemaker recipients can induce electrical and mechanical dyssynchrony, leading to pacing-induced cardiomyopathy, compromised systolic function, and symptoms of heart failure (HF).
The upgrade to Multisite Pacing (MSP), or Cardiac Resynchronization Therapy, is a physiological approach aimed at restoring cardiac synchrony and optimizing hemodynamic performance.
Studies demonstrate its potential to improve ejection fraction and functional status.
Objective This study evaluates the clinical and hemodynamic outcomes of a cohort of patients who underwent an upgrade from a dual-chamber pacemaker to Multisite Pacing at a specialized center.
Methods Between March 2006 and October 2025, 914 MSP devices were implanted at our service.
This analysis focused on 71 patients who were upgraded from a dual-chamber pacemaker to MSP due to a widened QRS complex secondary to chronic RV apical pacing, ventricular dyssynchrony, and persistent HF symptoms despite optimized medical therapy.
The procedure involved coronary sinus cannulation via the femoral vein and left subclavian vein punctures for lead insertion, followed by venography to optimize the left ventricular lead position.
Device programming targeted the shortest possible QRS interval.
Patient characteristics and post-upgrade follow-up data, particularly regarding ejection fraction (EF), were collected.
Results The 71 upgraded patients represented 7.
8% of the total MSP implantations.
The mean age was 60.
5 years (range 45 to 76 years), and 64.
8% were male.
Underlying etiologies included Chagas Disease (47.
9%), Coronary Artery Disease (22.
5%), and Valvular Heart Disease (11.
3%).
The overall technical and clinical success rate for the upgrade procedure was 77.
5%.
Notably, there were no reported complications during or after the procedure.
Of the patients, 77.
5% received a system associated with an Implantable Cardioverter-Defibrillator (CRT-D).
In 52 patients, there was a significant increase in Ejection Fraction (EF) of 73.
2% after 12 months of follow-up.
Conclusion The upgrade from a dual-chamber pacemaker to Multisite Pacing is an effective and safe intervention, demonstrating a high success rate and a clinically significant improvement in Ejection Fraction (73.
2%) in patients with pacing-induced dyssynchrony and refractory heart failure, confirming relevant hemodynamic and functional benefits.

Related Results

e0650 The effects of biventricular synchronous pacing on CBF, MVO2 and CWE in dogs
e0650 The effects of biventricular synchronous pacing on CBF, MVO2 and CWE in dogs
Objective To compare the effects of biventricular synchronous pacing with different pacing site on coronary Blood flow (CBF), myocardial oxygen consumption (MVO2)...
Long‐Term Follow‐up Impact of Dual‐Chamber Pacing on Patients with Hypertrophic Obstructive Cardiomyopathy
Long‐Term Follow‐up Impact of Dual‐Chamber Pacing on Patients with Hypertrophic Obstructive Cardiomyopathy
BackgroundPacing has been proposed as a treatment for patients with hypertrophic obstructive cardiomyopathy (HOCM), but there are few studies with long‐term follow‐up. We evaluated...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
GW24-e3507 Acute Effects of Rotation and Twist at Different Cardiac Pacing Sites Using Speckle Tracking Imaging
GW24-e3507 Acute Effects of Rotation and Twist at Different Cardiac Pacing Sites Using Speckle Tracking Imaging
Objectives Different cardiac site pacing may lead to different changes in the mechanics of left ventricular (LV) function, but how it affects LV rotation and twis...
Deep septal pacing for pacemaker-induced cardiomyopathy
Deep septal pacing for pacemaker-induced cardiomyopathy
Abstract Background Conventional right ventricular pacing can impair left ventricular function and cause heart failure, known as...
Acute Changes in Cardiac Synchrony and Output According to RV Pacing Sites in Koreans with Normal Cardiac Function
Acute Changes in Cardiac Synchrony and Output According to RV Pacing Sites in Koreans with Normal Cardiac Function
Introduction: The synchrony of the pacing heart can be affected by the right ventricular (RV) pacing site and is crucial to cardiac function in pacemaker recipients. We evaluated t...

Back to Top