Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Capacitive Interdigitated Electrodes Sensor for the Field Device to Measure Moisture Content in the Nitrile Gloves Manufacturing Industry

View through CrossRef
This paper investigates the impedance spectroscopy technique in determining moisture content in Nitrile gloves. Interdigitated electrode was designed and fabricated, then evaluated on LCR Impedance meter subjected to frequency range of 100Hz, 120Hz, 1kHz, 10kHz, 20kHz and 100kHz. Samples of Nitrile gloves were compounded and prepared for different moisture content level and regression analysis was performed to evaluate the relationships between capacitance and moisture content of the glove samples. Experimental results indicated that the capacitance value is a strong function of moisture content in gloves and also that the capacitance of moisture content in Nitrile gloves decreased with increasing drying time over the measured frequency range whilst statistical analysis results have confirmed that the 1kHz, 10kHz and 20kHz signal frequencies have highest reliable prediction of the nitrile gloves’ moisture content with high R2 value of 0.96, 0.97 and 0.97, respectively. The ability to determine average moisture content of Nitrile gloves via a non-destructive and online method, utilizing a low-cost instrument, will be of considerable use in the glove industry. This method could also be extended to other types of gloves and rubber products.
Title: Capacitive Interdigitated Electrodes Sensor for the Field Device to Measure Moisture Content in the Nitrile Gloves Manufacturing Industry
Description:
This paper investigates the impedance spectroscopy technique in determining moisture content in Nitrile gloves.
Interdigitated electrode was designed and fabricated, then evaluated on LCR Impedance meter subjected to frequency range of 100Hz, 120Hz, 1kHz, 10kHz, 20kHz and 100kHz.
Samples of Nitrile gloves were compounded and prepared for different moisture content level and regression analysis was performed to evaluate the relationships between capacitance and moisture content of the glove samples.
Experimental results indicated that the capacitance value is a strong function of moisture content in gloves and also that the capacitance of moisture content in Nitrile gloves decreased with increasing drying time over the measured frequency range whilst statistical analysis results have confirmed that the 1kHz, 10kHz and 20kHz signal frequencies have highest reliable prediction of the nitrile gloves’ moisture content with high R2 value of 0.
96, 0.
97 and 0.
97, respectively.
The ability to determine average moisture content of Nitrile gloves via a non-destructive and online method, utilizing a low-cost instrument, will be of considerable use in the glove industry.
This method could also be extended to other types of gloves and rubber products.

Related Results

Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Commercial wet Silver and Silver Chloride electrodes are used to monitor electrocardiogram (ECG) signals in numerous bioimpedance applications. These electrodes are frequently sing...
Chemical Resistant Improvement of Natural Rubber and Nitrile Gloves by Coating with Hydrophobic Film
Chemical Resistant Improvement of Natural Rubber and Nitrile Gloves by Coating with Hydrophobic Film
In this paper, we report innovative gloves that are coated with hydrophobic film such that the outer surface of the gloves is hydrophobic. A coating precursor containing polymethyl...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
British Food Journal Volume 45 Issue 1 1943
British Food Journal Volume 45 Issue 1 1943
The complex cellular structure and chemical nature of fruit and vegetable tissues retard evaporation so that under no conditions of temperature and humidity does the rate of evapor...
Nitrile glove composition and performance—Substandard properties and inaccurate packaging information
Nitrile glove composition and performance—Substandard properties and inaccurate packaging information
The durability and mechanical properties of synthetic medical gloves, such as those made from nitrile, vary drastically depending on the manufacturer. This study reports the chemic...
Permeation of human scent through laboratory examination gloves
Permeation of human scent through laboratory examination gloves
AbstractIt is generally accepted in the canine detection industry that a barrier (such as a glove) should be used between a human and evidence or canine training aids in order to p...
Additive Manufacturing of Photocurable PVDF-Based Capacitive Sensor
Additive Manufacturing of Photocurable PVDF-Based Capacitive Sensor
Abstract The demand for the capacitive sensor has attracted substantial attention in monitoring pressure due to its distinctive design and passive nature with versat...

Back to Top