Javascript must be enabled to continue!
Comparison of quite time ionospheric total electron content from IRI-2016 model and GPS observations
View through CrossRef
Abstract. Earth's ionosphere is an important medium of radio wave propagation in modern times. However, the effective use of ionosphere depends on the understanding of its spatio-temporal variability. Towards this end, a number of ground and space-based monitoring facilities have been set up over the years. This is also complemented by model-based studies. However, assessment of the performance of the ionospheric models in capturing observations needs to be conducted. In this work, the performance of IRI-2016 model in simulating total electron content (TEC) observed by network of global position System (GPS) is evaluated based on RMSE, bias, correlation and categorical metrics such as Quantile Probability of Detection (QPOD), Quantile False Alarm Ratio (QFAR), Quantile Categorical Miss (QCM), and Quantile Critical Success Index(QCSI). IRI-2016 model simulations are evaluated against GPS-TEC observations during the solar minima 2008 and maxima 2013. Higher correlation, low RMSE and bias between the modeled and measured TEC values are observed during solar minima than solar maxima. The IRI-2016 model TEC agrees with GPS-TEC strongly over higher latitudes than over tropics in general and EIA crest regions in particular as demonstrated by low RMSE and bias. However, the phases of modeled and simulated TEC agree strongly over the rest of the globe with the exception of the polar regions as indicated by high correlation during all solar activities. Moreover, the performance of the model in capturing extreme values over magnetic equator, mid- and high-latitudes is poor. This has been noted from a decrease in QPOD, QCSI and an increase in QCM and QFAR over most of the globe with an increase in the threshold percentile values of TEC to be simulated from 10 % to 90 % during both solar minimum and maximum periods. The performance of IRI-2016 in correctly simulating observed low (as low as 10th percentile) and high (high than 90th percentile) TEC over EIA crest regions is reasonably good given that IRI-2016 is a climatological model despite large RMSE and positive model bias. Therefore, this study reveals the strength of the IRI-2016 model, which was concealed due to large RMSE and positive bias, in correctly simulating the observed TEC distribution during all seasons and solar activities for the first time. However, it is also worth noting that the performance of IRI-2016 model is relatively poor in 2013 compared to that of 2008 at the higher ends of the TEC distribution.
Title: Comparison of quite time ionospheric total electron content from
IRI-2016 model and GPS observations
Description:
Abstract.
Earth's ionosphere is an important medium of radio wave propagation in modern times.
However, the effective use of ionosphere depends on the understanding of its spatio-temporal variability.
Towards this end, a number of ground and space-based monitoring facilities have been set up over the years.
This is also complemented by model-based studies.
However, assessment of the performance of the ionospheric models in capturing observations needs to be conducted.
In this work, the performance of IRI-2016 model in simulating total electron content (TEC) observed by network of global position System (GPS) is evaluated based on RMSE, bias, correlation and categorical metrics such as Quantile Probability of Detection (QPOD), Quantile False Alarm Ratio (QFAR), Quantile Categorical Miss (QCM), and Quantile Critical Success Index(QCSI).
IRI-2016 model simulations are evaluated against GPS-TEC observations during the solar minima 2008 and maxima 2013.
Higher correlation, low RMSE and bias between the modeled and measured TEC values are observed during solar minima than solar maxima.
The IRI-2016 model TEC agrees with GPS-TEC strongly over higher latitudes than over tropics in general and EIA crest regions in particular as demonstrated by low RMSE and bias.
However, the phases of modeled and simulated TEC agree strongly over the rest of the globe with the exception of the polar regions as indicated by high correlation during all solar activities.
Moreover, the performance of the model in capturing extreme values over magnetic equator, mid- and high-latitudes is poor.
This has been noted from a decrease in QPOD, QCSI and an increase in QCM and QFAR over most of the globe with an increase in the threshold percentile values of TEC to be simulated from 10 % to 90 % during both solar minimum and maximum periods.
The performance of IRI-2016 in correctly simulating observed low (as low as 10th percentile) and high (high than 90th percentile) TEC over EIA crest regions is reasonably good given that IRI-2016 is a climatological model despite large RMSE and positive model bias.
Therefore, this study reveals the strength of the IRI-2016 model, which was concealed due to large RMSE and positive bias, in correctly simulating the observed TEC distribution during all seasons and solar activities for the first time.
However, it is also worth noting that the performance of IRI-2016 model is relatively poor in 2013 compared to that of 2008 at the higher ends of the TEC distribution.
Related Results
Contributions to ionospheric electron density retrieval
Contributions to ionospheric electron density retrieval
La transformada de Abel es una técnica de inversión usada frecuentemente en radio ocultaciones (RO) que, en el contexto ionosférico, permite deducir densidades electrónicas a parti...
Klobuchar, NeQuickG, BDGIM, GLONASS, IRI-2016, IRI-2012, IRI-Plas, NeQuick2, and GEMTEC Ionospheric Models: A Comparison in Total Electron Content and Positioning Domains
Klobuchar, NeQuickG, BDGIM, GLONASS, IRI-2016, IRI-2012, IRI-Plas, NeQuick2, and GEMTEC Ionospheric Models: A Comparison in Total Electron Content and Positioning Domains
Global navigation satellite systems (GNSS) provide a great data source about the ionosphere state. These data can be used for testing ionosphere models. We studied the performance ...
Modification of the solar activity indices in the International Reference Ionosphere IRI and IRI-Plas models due to recent revision of sunspot number time series
Modification of the solar activity indices in the International Reference Ionosphere IRI and IRI-Plas models due to recent revision of sunspot number time series
The International Reference Ionosphere (IRI) imports global effective ionospheric IG12 index based on ionosonde measurements of the critical frequency foF2 as a proxy of solar acti...
Modification of the solar activity indices in the International Reference Ionosphere IRI and IRI-Plas models due to recent revision of sunspot number time series
Modification of the solar activity indices in the International Reference Ionosphere IRI and IRI-Plas models due to recent revision of sunspot number time series
The International Reference Ionosphere (IRI) imports global effective ionospheric IG12 index based on ionosonde measurements of the critical frequency foF2 as a proxy of solar acti...
Assessment of the IRI-2016 and modified IRI 2016 models in China: Comparison with GNSS-TEC and ionosonde data
Assessment of the IRI-2016 and modified IRI 2016 models in China: Comparison with GNSS-TEC and ionosonde data
<p>Ionosphere is one of the main errors in the signal propagation of global navigation system satellite (GNSS), and it is also the key issue of space weather. The Int...
Contributions to ionospheric modeling with GNSS in mapping function, tomography and polar electron
Contributions to ionospheric modeling with GNSS in mapping function, tomography and polar electron
This dissertation focuses on determining the vertical electron content distribution in low and high vertical resolution from ground-based and LEO on board GNSS data and improving t...
Total Electron Content Variation Over HALY (Al-Jouf), Saudi Arabia and Comparison with IRI-2012 and IRI-2016 Models
Total Electron Content Variation Over HALY (Al-Jouf), Saudi Arabia and Comparison with IRI-2012 and IRI-2016 Models
Ionospheric perdition studies are very few over Saudi Arabia due to less availability of data measurement. Although such kind of studies have been carried out all over the world, t...
Predictability of Ionosphere using Assimilative Empirical Model IRTAM
Predictability of Ionosphere using Assimilative Empirical Model IRTAM
<p>Real-time assimilative <em>empirical </em>models based on the International Reference Ionosphere (IRI) [1], a 3D quiet-time climatology...

