Javascript must be enabled to continue!
Immunoassay of serum polypeptide hormones by using 125I-labelled anti(-immunoglobulin G) antibodies
View through CrossRef
1. A technique for indirectly labelling antibodies to polypeptide hormones, by combining them with radioactively labelled anti-(immunoglobulin G) is described. (a) 125I-labelled anti-(rabbit immunoglobulin G) and anti-(guinea-pig immunoglobulin G) antibodies with high specific radioactivity were prepared after purification of the antibodies on immunoadsorbents containing the respective antigens. (b) Rabbit immunoglobulin G antibodies to human growth hormone, porcine glucagon and guinea-pig immunoglobulin G antibodies to bovine insulin and bovine parathyroid hormone were combined with immunoadsorbents containing the respective polypeptide hormone antigen. (c) The immunoglobulin G antibodies to the polypeptide hormones were reacted with 125-I-labelled anti-(immunoglobulin G) antibodies directed against the appropriate species of immunoglobulin G,and the anti-hormone antibodies were combined with the hormone-containing immunoadsorbent. (d) 125I-labelled anti-(immunoglobulin G) antibodies and anti-hormone antibodies were simultaneously eluted from the hormone-containing immunoadsorbent by dilute HCl, pH 2.0. After elution the anti-(immunoglobulin G) antibodies and antihormone antibodies were allowed to recombine at pH 8.0 and 4 degrees C. 2. The resultant immunoglobulin G-anti-immunoglobulin G complex was used in immunoradiometric (labelled antibody) and two-site assays of the respective polypeptide hormone. 3. By using these immunoassays, concentrations down to 90pg of human growth hormone/ml, 100 pg of bovine insulin/ml, 80 pg of bovine parathyroid hormone/ml and 150 pg of glucagon/ml were readily detected. Assays of human plasma for growth hormone and insulin by these methods showed good agreement with results obtained by using a directly 125I-labelled anti-hormone antibody in an immunoradiometric assay of human growth hormone or by radioimmunoassay of human insulin. 4. The method described allows immunoradiometric or two-site assays to be performed starting with as little as 450 ng of polypeptide hormone-antibody protein. An additional advantage of the method is that a single iodination of the readily available antibodies to immunoglobulin G allows the establishemnt of several polypeptide hormone assays
Title: Immunoassay of serum polypeptide hormones by using 125I-labelled anti(-immunoglobulin G) antibodies
Description:
1.
A technique for indirectly labelling antibodies to polypeptide hormones, by combining them with radioactively labelled anti-(immunoglobulin G) is described.
(a) 125I-labelled anti-(rabbit immunoglobulin G) and anti-(guinea-pig immunoglobulin G) antibodies with high specific radioactivity were prepared after purification of the antibodies on immunoadsorbents containing the respective antigens.
(b) Rabbit immunoglobulin G antibodies to human growth hormone, porcine glucagon and guinea-pig immunoglobulin G antibodies to bovine insulin and bovine parathyroid hormone were combined with immunoadsorbents containing the respective polypeptide hormone antigen.
(c) The immunoglobulin G antibodies to the polypeptide hormones were reacted with 125-I-labelled anti-(immunoglobulin G) antibodies directed against the appropriate species of immunoglobulin G,and the anti-hormone antibodies were combined with the hormone-containing immunoadsorbent.
(d) 125I-labelled anti-(immunoglobulin G) antibodies and anti-hormone antibodies were simultaneously eluted from the hormone-containing immunoadsorbent by dilute HCl, pH 2.
After elution the anti-(immunoglobulin G) antibodies and antihormone antibodies were allowed to recombine at pH 8.
0 and 4 degrees C.
2.
The resultant immunoglobulin G-anti-immunoglobulin G complex was used in immunoradiometric (labelled antibody) and two-site assays of the respective polypeptide hormone.
3.
By using these immunoassays, concentrations down to 90pg of human growth hormone/ml, 100 pg of bovine insulin/ml, 80 pg of bovine parathyroid hormone/ml and 150 pg of glucagon/ml were readily detected.
Assays of human plasma for growth hormone and insulin by these methods showed good agreement with results obtained by using a directly 125I-labelled anti-hormone antibody in an immunoradiometric assay of human growth hormone or by radioimmunoassay of human insulin.
4.
The method described allows immunoradiometric or two-site assays to be performed starting with as little as 450 ng of polypeptide hormone-antibody protein.
An additional advantage of the method is that a single iodination of the readily available antibodies to immunoglobulin G allows the establishemnt of several polypeptide hormone assays.
Related Results
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Abstract
Introduction
Transfusion medicine promotes the safety of blood transfusions by rigorously testing to eliminate risks of infection and hemolytic. The efficacy (to correct ...
125I Low Dose Rate Radiation Increases Radiotherapy Sensitivity on Esophageal Cancer Cells via Multiple Mechanisms
125I Low Dose Rate Radiation Increases Radiotherapy Sensitivity on Esophageal Cancer Cells via Multiple Mechanisms
Abstract
Objective: To determine the biological effectiveness of iodine 125 (125I) radioactive seeds continuous low dose rate radiation on the human esophageal cancer cell ...
The hormone-binding unit of luteinizing hormone receptor
The hormone-binding unit of luteinizing hormone receptor
Rat ovarian luteinizing hormone/human choriogonadotropin binding sites were labelled with 125I-choriogonadotropin in vivo, and the resulting 125I-choriogonadotropin-receptor comple...
Autoantibody Profile in Systemic Lupus Erythematosus Patients
Autoantibody Profile in Systemic Lupus Erythematosus Patients
AbstractSystemic lupus erythematosus (SLE) is an autoimmune disease, in which the etiology is not well-understood; however, interactions between environmental and genetic factors i...
Utility of anti-immunoglobulin IgA, IgG, IgM, Kappa, Lambda - FITC (conjugate) cocktail in routine renal pathology practice
Utility of anti-immunoglobulin IgA, IgG, IgM, Kappa, Lambda - FITC (conjugate) cocktail in routine renal pathology practice
Abstract
Background
Immunofluorescence studies on frozen sections are an essential component in the evaluation of renal biopsies. The basic panel in...
The Impact of Anti-HLA Antibodies on the Prognosis of Allogeneic Hematopoietic Stem Cell Transplantation in Myelodysplastic Syndrome
The Impact of Anti-HLA Antibodies on the Prognosis of Allogeneic Hematopoietic Stem Cell Transplantation in Myelodysplastic Syndrome
Objective To investigate the risk factors of positive anti-HLA antibodies in myelodysplastic syndrome (MDS) patients and gain insights into the impact of anti-HLA antibodies in all...
Anti‐SSA antibodies are present in immunoglobulin preparations
Anti‐SSA antibodies are present in immunoglobulin preparations
BackgroundAnti‐SSA autoantibodies are among the most frequently detected autoantibodies and have traditionally been associated with Sjögren's syndrome (SjS) and systemic lupus eryt...
Immune-hormonal imbalance in chemical cancerogenesis
Immune-hormonal imbalance in chemical cancerogenesis
The present article deals with experimental and clinical aspects of immuno-hormonal interactions in chemical carcinogenesis i.e., formation of DNA-adducts with chemical carcinogens...


