Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Diffusion Weighted Image Co-registration: Investigation of Best Practices

View through CrossRef
1. Abstract The registration or alignment of diffusion weighted images (DWI) with other imaging modalities is a critical step in neuroimaging analysis. Within-subject T1-DWI co-registration is particularly instrumental. DWI-derived scalar images are commonly used as intermediates for T1-DWI co-registration, and the resulting registration transforms are applied to all other scalar images for analysis. The ideal registration intermediate should register well to T1 and other multimodal images and be practically easy to obtain. It is however, currently unclear which DWI-derived scalar image serves as the best intermediate. We aim to determine the best, practical, intermediate for image co-registration. T1 and DWI images were acquired from 20 healthy subjects. DWIs were acquired with 60 directions. Six DWI-derived scalar images were compared including: 1) fractional anisotropy (FA); 2) generalized FA (GFA); 3) B0 images; 4) mean DWIs with the B0 image (MDWI); 5) anisotropic power (AP) images. AP showed the smallest variability in registration improvements across all the tested DWI derived scalar images, and show the highest average percent changes with CC registration cost function (CC=1.2%, MI=15%). In contrast, the FA and GFA transforms resulted in significantly poorer registration across DWI types. The AP image was the DWI-derived scalar image that provided the most consistent registration to all other images. Practically, it is generated easily and so could be implemented in basic and clinical research pipelines currently using other intermediates. Given these findings, it is recommended that AP images be used for T1–DWI co-registration, and that FA and GFA images in particular be avoided.
Title: Diffusion Weighted Image Co-registration: Investigation of Best Practices
Description:
1.
Abstract The registration or alignment of diffusion weighted images (DWI) with other imaging modalities is a critical step in neuroimaging analysis.
Within-subject T1-DWI co-registration is particularly instrumental.
DWI-derived scalar images are commonly used as intermediates for T1-DWI co-registration, and the resulting registration transforms are applied to all other scalar images for analysis.
The ideal registration intermediate should register well to T1 and other multimodal images and be practically easy to obtain.
It is however, currently unclear which DWI-derived scalar image serves as the best intermediate.
We aim to determine the best, practical, intermediate for image co-registration.
T1 and DWI images were acquired from 20 healthy subjects.
DWIs were acquired with 60 directions.
Six DWI-derived scalar images were compared including: 1) fractional anisotropy (FA); 2) generalized FA (GFA); 3) B0 images; 4) mean DWIs with the B0 image (MDWI); 5) anisotropic power (AP) images.
AP showed the smallest variability in registration improvements across all the tested DWI derived scalar images, and show the highest average percent changes with CC registration cost function (CC=1.
2%, MI=15%).
In contrast, the FA and GFA transforms resulted in significantly poorer registration across DWI types.
The AP image was the DWI-derived scalar image that provided the most consistent registration to all other images.
Practically, it is generated easily and so could be implemented in basic and clinical research pipelines currently using other intermediates.
Given these findings, it is recommended that AP images be used for T1–DWI co-registration, and that FA and GFA images in particular be avoided.

Related Results

Verification of image registration for the commercial treatmetn planning systems
Verification of image registration for the commercial treatmetn planning systems
Image registration is essential in treatment planning and position verification for highly radiation conformal delivery methods. The purpose of this study is to evaluate the accura...
Comment on: Macroscopic water vapor diffusion is not enhanced in snow
Comment on: Macroscopic water vapor diffusion is not enhanced in snow
Abstract. The central thesis of the authors’ paper is that macroscopic water vapor diffusion is not enhanced in snow compared to diffusion through humid air alone. Further, mass di...
Reporting of Retrospective Registration in Clinical Trial Publications: a Cross-Sectional Study of German Trials
Reporting of Retrospective Registration in Clinical Trial Publications: a Cross-Sectional Study of German Trials
Objective: Prospective registration has been widely implemented and accepted as a best practice in clinical research, but retrospective registration is still commonly found. We ass...
Public Procedures for State Registration
Public Procedures for State Registration
The paper reviews the types of state registration carried out to meet private and public needs, as well as the content of the relevant administrative procedures. The author substan...
Prospective Registration of Trials: Where we are, why, and how we could get better
Prospective Registration of Trials: Where we are, why, and how we could get better
Objectives: Transparent trial conduct requires prospective registration of a randomized controlled trial before the enrolment of the first participant. Registration aims to minimiz...
Diffusion and Ion Conduction in Cation-Conducting Oxide Glasses
Diffusion and Ion Conduction in Cation-Conducting Oxide Glasses
In this Chapter we review knowledge about diffusion and cation conduction in oxide glasses. We first remind the reader in Section 1 of major aspects of the glassy state and recall ...
Analytical and Numerical Analysis for Temporal Anomalous Diffusion Flow in Unconventional Fractured Reservoirs
Analytical and Numerical Analysis for Temporal Anomalous Diffusion Flow in Unconventional Fractured Reservoirs
Abstract Understanding the phenomenal anomalous diffusion flow mechanisms in unconventional fractured porous media is one of the objectives of this paper. It aims to...
Who gets counted? Understanding low female death registration in India
Who gets counted? Understanding low female death registration in India
Background Civil Registration and Vital Statistics (CRVS) systems are essential for governance, public health, and achieving SDGs however, gender gaps limit wom...

Back to Top