Javascript must be enabled to continue!
Simultaneous acquisition of MR angiography and venography (MRAV)
View through CrossRef
AbstractA dual‐echo pulse sequence for simultaneous acquisition of MR angiography and venography (MRAV) is developed. Data acquisition of the second echo for susceptibility‐weighted imaging–based MR venography is added to the conventional three‐dimensional (3D) time‐of‐flight (TOF) MRA pulse sequence. Using this dual‐echo acquisition approach, the venography data can be acquired without increasing the repetition time, and, therefore, the scan duration of routine TOF MRA scans is maintained. The feasibility of simultaneous acquisition of MRAV is presented in brain scans at different spatial resolutions. The effect of spatial resolution on vein‐to‐background contrast is also demonstrated. Venous contrast is improved in high‐resolution (0.52 × 0.52 × 1.6 mm3) images compared to that in standard‐resolution (0.78 × 0.78 × 1.6 mm3) images. This MRAV technique enables the acquisition of MR venography without the need of an extra scan or injection of contrast agent in routine clinical brain exams at 3T. Magn Reson Med 59:954–958, 2008. © 2008 Wiley‐Liss, Inc.
Title: Simultaneous acquisition of MR angiography and venography (MRAV)
Description:
AbstractA dual‐echo pulse sequence for simultaneous acquisition of MR angiography and venography (MRAV) is developed.
Data acquisition of the second echo for susceptibility‐weighted imaging–based MR venography is added to the conventional three‐dimensional (3D) time‐of‐flight (TOF) MRA pulse sequence.
Using this dual‐echo acquisition approach, the venography data can be acquired without increasing the repetition time, and, therefore, the scan duration of routine TOF MRA scans is maintained.
The feasibility of simultaneous acquisition of MRAV is presented in brain scans at different spatial resolutions.
The effect of spatial resolution on vein‐to‐background contrast is also demonstrated.
Venous contrast is improved in high‐resolution (0.
52 × 0.
52 × 1.
6 mm3) images compared to that in standard‐resolution (0.
78 × 0.
78 × 1.
6 mm3) images.
This MRAV technique enables the acquisition of MR venography without the need of an extra scan or injection of contrast agent in routine clinical brain exams at 3T.
Magn Reson Med 59:954–958, 2008.
© 2008 Wiley‐Liss, Inc.
Related Results
P-023 3D venography in neurointerventional applications
P-023 3D venography in neurointerventional applications
Introduction
3D venography has been reported previously as an indirect imaging method for visualization of various intracranial venous structures (ex.cavernous si...
DISCREPANCIES BETWEEN VENOGRAPHY AND REAL TIME B MODE ULTRASOUND IMAGING IN THE DIAGNOSIS OF DEEP VEIN THROMBOSIS
DISCREPANCIES BETWEEN VENOGRAPHY AND REAL TIME B MODE ULTRASOUND IMAGING IN THE DIAGNOSIS OF DEEP VEIN THROMBOSIS
Methods : in this prospective study, real time B Mode ultrasound imaging (USI) was compared to bilateral ascending contrast venography, double blindly, in 430 patients suspected of...
Feasibility of energy-resolved angiography
Feasibility of energy-resolved angiography
<p dir="ltr">Cardiovascular disease (CVD) is the leading cause of death globally, with coronary heart disease being one of the most common types of CVD. Two-dimensional x-ray...
Feasibility of energy-resolved angiography
Feasibility of energy-resolved angiography
<p dir="ltr">Cardiovascular disease (CVD) is the leading cause of death globally, with coronary heart disease being one of the most common types of CVD. Two-dimensional x-ray...
Overview of Cerebral Angiography Results in Young Stroke Patients at Pelni Hospital
Overview of Cerebral Angiography Results in Young Stroke Patients at Pelni Hospital
Background and purpose: The average age of stroke patients is decreasing, with the majority of cases currently comprising young individuals. However, there are still limited cerebr...
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract
Introduction
Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
Transcatheter embolisation in non-variceal gastrointestinal haemorrhage: an institutional review
Transcatheter embolisation in non-variceal gastrointestinal haemorrhage: an institutional review
Introduction
The aim of this study was to assess the role of pre-angiographic imaging and the technical and clinical success of angiographic embolisation in the m...
Incomplete Acquisition, Attrition and Maintenance of Heritage Speakers’ Family Language: Iranians in New Zealand
Incomplete Acquisition, Attrition and Maintenance of Heritage Speakers’ Family Language: Iranians in New Zealand
<p>This dissertation is composed of a quantitative investigation of Incomplete Heritage Language Acquisition and Attrition in heritage speakers’ vocabulary knowledge. This po...

