Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Vibration Characteristics of Beam Structure Attached with Vibration Absorbers at its Vibrational Node and Antinode by Finite Element Analysis

View through CrossRef
In this study, the vibration characteristics of fixed ends beam are analysed after attached with dynamic vibration absorbers at vibrational node and antinode by simulation using ANSYS APDL. This study aim to obtain the best location and optimum number of DVAs placed on the fixed ends beam in order to reduce vibration of beam. The dynamic vibration absorber were attached to the fixed ends beam vibrational node and antinode for a total of three modes of vibration. The 0.84 m long beam is modelled by ANSYS and divided into 21 elements where each element is 0.04 m. A harmonic force, Fo of 28.84 N is exerted at node 3 of beam element. Modal analysis and harmonic analysis are carried out in this study to obtain the natural frequency and frequency response of the beam respectively. The vibration characteristics of fixed ends beam without DVA and beam attached with DVAs were compared. The simulation results show reduction of vibration amplitude of the beam especially when the DVA were attached at the vibrational antinode. The DVA amplitude increase when amplitude of beam decreases. From this study, it is proved that DVAs absorb vibration of the beam structure. The best position to attach DVAs is the vibrational antinode based on the modes of vibration. The increment of DVAs number will not affect the percentage reduction of vibration amplitude as long as the DVAs are placed at optimum location.  
Title: Vibration Characteristics of Beam Structure Attached with Vibration Absorbers at its Vibrational Node and Antinode by Finite Element Analysis
Description:
In this study, the vibration characteristics of fixed ends beam are analysed after attached with dynamic vibration absorbers at vibrational node and antinode by simulation using ANSYS APDL.
This study aim to obtain the best location and optimum number of DVAs placed on the fixed ends beam in order to reduce vibration of beam.
The dynamic vibration absorber were attached to the fixed ends beam vibrational node and antinode for a total of three modes of vibration.
The 0.
84 m long beam is modelled by ANSYS and divided into 21 elements where each element is 0.
04 m.
A harmonic force, Fo of 28.
84 N is exerted at node 3 of beam element.
Modal analysis and harmonic analysis are carried out in this study to obtain the natural frequency and frequency response of the beam respectively.
The vibration characteristics of fixed ends beam without DVA and beam attached with DVAs were compared.
The simulation results show reduction of vibration amplitude of the beam especially when the DVA were attached at the vibrational antinode.
The DVA amplitude increase when amplitude of beam decreases.
From this study, it is proved that DVAs absorb vibration of the beam structure.
The best position to attach DVAs is the vibrational antinode based on the modes of vibration.
The increment of DVAs number will not affect the percentage reduction of vibration amplitude as long as the DVAs are placed at optimum location.
 .

Related Results

Shape optimization for beam structural design
Shape optimization for beam structural design
"Optimization is concerned with achieving the best outcome of a given objective while satisfying certain restrictions. The central purpose of structural analysis is to predict the ...
Study of Passive Vibration Absorbers Attached on Beam Structure
Study of Passive Vibration Absorbers Attached on Beam Structure
Structural vibration is undesirable, wasting energy and possibly leading to excessive deflections and structure and machine’s failure. In order to reduce structural vibration, one ...
Analisis Numerik Kuat Lentur Balok Support Beam Curve Tile Beton Semi Pracetak Dengan Variasi Panjang Bentangan
Analisis Numerik Kuat Lentur Balok Support Beam Curve Tile Beton Semi Pracetak Dengan Variasi Panjang Bentangan
Semi precast slab is a combination of precast concrete which consist of the support beam and curve tile with the cast in place concrete. During the working process, support beam wi...
Vibration Analysis of a Beam Structure Attached with a Dynamic Vibration Absorber
Vibration Analysis of a Beam Structure Attached with a Dynamic Vibration Absorber
In this paper the transverse vibration of a fixed-fixed end beam will be investigated by experimental measurement. This paper is concerned with the classical theory formula as well...
Predictors of False-Negative Axillary FNA Among Breast Cancer Patients: A Cross-Sectional Study
Predictors of False-Negative Axillary FNA Among Breast Cancer Patients: A Cross-Sectional Study
Abstract Introduction Fine-needle aspiration (FNA) is commonly used to investigate lymphadenopathy of suspected metastatic origin. The current study aims to find the association be...
Blades condition monitoring using shaft torsional vibration signals
Blades condition monitoring using shaft torsional vibration signals
PurposeThe purpose of this paper is to validate mathematically the feasibility of extracting the rotating blades vibration condition from the shaft torsional vibration measurement....

Back to Top