Unpacking Galvanic Vestibular Stimulation using simulations and relating current flow to reported motions: Comparison across common and specialized electrode placements

View through CrossRef
Background Galvanic Vestibular Stimulation (GVS) is a non-invasive electrical stimulation technique that is typically used to probe the vestibular system. When using direct current or very low frequency sine, GVS causes postural sway or perception of illusory (virtual) motions. GVS is commonly delivered using two electrodes placed at the mastoids, however, placements involving additional electrodes / locations have been employed. Our objective was to systematically evaluate all known GVS electrode placements, compare induced current flow, and how it relates to the archetypal sway and virtual motions. The ultimate goal is to help users in having a better understanding of the effects of different placements. Methods We simulated seven GVS electrode placements with same total injected current using an ultra-high resolution model. Induced electric field (EF) patterns at the cortical and the level of vestibular organs (left and right) were determined. A range of current flow metrics including potential factors such as inter-electrode separation, percentage of current entering the cranial cavity, and symmetricity were calculated. Finally, we relate current flow to reported GVS motions. Results As expected, current flow patterns are electrode placement specific. Placements with two electrodes generally result in higher EF magnitude. Placements with four electrodes result in lower percentage of current entering the cranial cavity. Symmetric placements do not result in similar EF values in the left and the right organs respectively- highlighting inherent anatomical asymmetry of the human head. Asymmetric placements were found to induce as much as ~3-fold higher EF in one organ over the other. The percentage of current entering the cranial cavity varies between ~15% and ~40% depending on the placement. Conclusions We expect our study to advance understanding of GVS and provide insight on probable mechanism of action of a certain electrode placement choice. The dataset generated across several metrics will support hypothesis testing relating empirical outcomes to current flow patterns. Further, the differences in current flow will guide stimulation strategy (what placement and how much scalp current to use) and facilitate a quantitatively informed rational / optimal decision.
Title: Unpacking Galvanic Vestibular Stimulation using simulations and relating current flow to reported motions: Comparison across common and specialized electrode placements
Description:
Background Galvanic Vestibular Stimulation (GVS) is a non-invasive electrical stimulation technique that is typically used to probe the vestibular system.
When using direct current or very low frequency sine, GVS causes postural sway or perception of illusory (virtual) motions.
GVS is commonly delivered using two electrodes placed at the mastoids, however, placements involving additional electrodes / locations have been employed.
Our objective was to systematically evaluate all known GVS electrode placements, compare induced current flow, and how it relates to the archetypal sway and virtual motions.
The ultimate goal is to help users in having a better understanding of the effects of different placements.
Methods We simulated seven GVS electrode placements with same total injected current using an ultra-high resolution model.
Induced electric field (EF) patterns at the cortical and the level of vestibular organs (left and right) were determined.
A range of current flow metrics including potential factors such as inter-electrode separation, percentage of current entering the cranial cavity, and symmetricity were calculated.
Finally, we relate current flow to reported GVS motions.
Results As expected, current flow patterns are electrode placement specific.
Placements with two electrodes generally result in higher EF magnitude.
Placements with four electrodes result in lower percentage of current entering the cranial cavity.
Symmetric placements do not result in similar EF values in the left and the right organs respectively- highlighting inherent anatomical asymmetry of the human head.
Asymmetric placements were found to induce as much as ~3-fold higher EF in one organ over the other.
The percentage of current entering the cranial cavity varies between ~15% and ~40% depending on the placement.
Conclusions We expect our study to advance understanding of GVS and provide insight on probable mechanism of action of a certain electrode placement choice.
The dataset generated across several metrics will support hypothesis testing relating empirical outcomes to current flow patterns.
Further, the differences in current flow will guide stimulation strategy (what placement and how much scalp current to use) and facilitate a quantitatively informed rational / optimal decision.

Related Results

EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Vestibular-Evoked Cerebral Potentials
Vestibular-Evoked Cerebral Potentials
The human vestibular cortex has mostly been approached using functional magnetic resonance imaging and positron emission tomography combined with artificial stimulation of the vest...
Vestibular-evoked myogenic potential (VEMP) triggered by galvanic vestibular stimulation recorded in the lower limbs v1
Vestibular-evoked myogenic potential (VEMP) triggered by galvanic vestibular stimulation recorded in the lower limbs v1
Galvanic vestibular stimulation (GVS) is a method that stimulates the vestibular afferents with a small current, triggering a motor reflex response in the posture-controlling muscl...
Noisy galvanic vestibular stimulation improves vestibular perception in bilateral vestibulopathy
Noisy galvanic vestibular stimulation improves vestibular perception in bilateral vestibulopathy
Abstract Background Patients with bilateral vestibulopathy (BVP) suffer from impaired vestibular motion perception that is linked to deficits in spa...
Boosting Oxygen Electrode Performance via a Redox-Treatment
Boosting Oxygen Electrode Performance via a Redox-Treatment
Introduction The transition to a sustainable energy system complying with climate policy targets is a huge societal challenge. “Hard to electri...

Back to Top