Javascript must be enabled to continue!
A Method to Determine Human Skin Heat Capacity Using a Non-Invasive Calorimetric Sensor
View through CrossRef
A calorimetric sensor has been designed to measure the heat flow dissipated by a 2 × 2 cm2 skin surface. In this work, a non-invasive method is proposed to determine the heat capacity and thermal conductance of the area of skin where the measurement is made. The method consists of programming a linear variation of the temperature of the sensor thermostat during its application to the skin. The sensor is modelled as a two-inputs and two-outputs system. The inputs are (1) the power dissipated by the skin and transmitted by conduction to the sensor, and (2) the power dissipated in the sensor thermostat to maintain the programmed temperature. The outputs are (1) the calorimetric signal and (2) the thermostat temperature. The proposed method consists of a sensor modelling that allows the heat capacity of the element where dissipation takes place (the skin) to be identified, and the transfer functions (TF) that link the inputs and outputs are constructed from its value. These TFs allow the determination of the heat flow dissipated by the surface of the human body as a function of the temperature of the sensor thermostat. Furthermore, as this variation in heat flow is linear, we define and determine an equivalent thermal resistance of the skin in the measured area. The method is validated with a simulation and with experimental measurements on the surface of the human body.
Title: A Method to Determine Human Skin Heat Capacity Using a Non-Invasive Calorimetric Sensor
Description:
A calorimetric sensor has been designed to measure the heat flow dissipated by a 2 × 2 cm2 skin surface.
In this work, a non-invasive method is proposed to determine the heat capacity and thermal conductance of the area of skin where the measurement is made.
The method consists of programming a linear variation of the temperature of the sensor thermostat during its application to the skin.
The sensor is modelled as a two-inputs and two-outputs system.
The inputs are (1) the power dissipated by the skin and transmitted by conduction to the sensor, and (2) the power dissipated in the sensor thermostat to maintain the programmed temperature.
The outputs are (1) the calorimetric signal and (2) the thermostat temperature.
The proposed method consists of a sensor modelling that allows the heat capacity of the element where dissipation takes place (the skin) to be identified, and the transfer functions (TF) that link the inputs and outputs are constructed from its value.
These TFs allow the determination of the heat flow dissipated by the surface of the human body as a function of the temperature of the sensor thermostat.
Furthermore, as this variation in heat flow is linear, we define and determine an equivalent thermal resistance of the skin in the measured area.
The method is validated with a simulation and with experimental measurements on the surface of the human body.
Related Results
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract
Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...
Association between skin-to-skin contact post-birth and breastfeeding behaviour: a cross-sectional study of Nigerian women using the 2018 Demographic Health Survey
Association between skin-to-skin contact post-birth and breastfeeding behaviour: a cross-sectional study of Nigerian women using the 2018 Demographic Health Survey
Background The World Health Organisation (WHO) recommends skin-to-skin contact at birth as part of the essential newborn care processes that can help improve breastfeeding behaviou...
Testing the Thermal Resistance and Power Capacity of Production Heat Pipes
Testing the Thermal Resistance and Power Capacity of Production Heat Pipes
In recent years heat pipes have become widely use in high performance air-cooled heat sinks for cooling electronics equipment. Such heat sinks rely on the heat pipes to collect hea...
The biology of incipient, pre-invasive or intraepithelial neoplasia
The biology of incipient, pre-invasive or intraepithelial neoplasia
Invasive tumors (cancers or malignant lesions) typically develop in the setting in which there is the presence of putative non-invasive lesions and the development of these non-inv...
[RETRACTED] Kerassentials Toenail Fungus Treatment, Kerassentials for Toenail Fungus, Kerasentials Nail Treatment v1
[RETRACTED] Kerassentials Toenail Fungus Treatment, Kerassentials for Toenail Fungus, Kerasentials Nail Treatment v1
[RETRACTED]kerassentials reviewsis another nail and skin support dietary enhancement would you say you are tired of your foot parasite? Do you need to confront a steady humiliation...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...

