Javascript must be enabled to continue!
Safety of Short-Term Discontinuation of Antiplatelet Therapy in Patients With Drug-Eluting Stents
View through CrossRef
Background—
Antiplatelet therapy is often discontinued in patients with drug-eluting stents who are undergoing surgical procedures. However, discontinuation of antiplatelet therapy is an important risk factor for late stent thrombosis. Our objective was to examine the safety of short-term discontinuation of antiplatelet therapy.
Methods and Results—
We systematically searched Medline for reported cases of late stent thrombosis and very late stent thrombosis published between January 2001 and July 2008. We restricted our search to Academic Research Consortium–defined definite cases. We identified 161 cases of late stent thrombosis or very late stent thrombosis from 84 articles (79 from case reports, 61 from registries, and 21 from randomized clinical trials). Patients had a mean age of 58.4±13.4 years, and 88% were male. A total of 19 cases occurred in patients who were receiving dual antiplatelet therapy at the time of the event. If patients stopped both antiplatelet agents simultaneously, the median time to event was 7 days. If patients had previously stopped a thienopyridine with no ill effect and subsequently stopped acetylsalicylic acid, the median time to event was also 7 days from the time of acetylsalicylic acid cessation. If the thienopyridine was stopped but acetylsalicylic acid was maintained, the median time to event was 122 days. Among the 48 patients who stopped both agents, 36 cases (75%) occurred within 10 days. Among the 94 patients who discontinued a thienopyridine but continued acetylsalicylic acid, only 6 cases (6%) occurred within 10 days.
Conclusion—
If acetylsalicylic acid therapy is maintained, short-term discontinuation of a thienopyridine may be relatively safe in patients with drug-eluting stents.
Ovid Technologies (Wolters Kluwer Health)
Title: Safety of Short-Term Discontinuation of Antiplatelet Therapy in Patients With Drug-Eluting Stents
Description:
Background—
Antiplatelet therapy is often discontinued in patients with drug-eluting stents who are undergoing surgical procedures.
However, discontinuation of antiplatelet therapy is an important risk factor for late stent thrombosis.
Our objective was to examine the safety of short-term discontinuation of antiplatelet therapy.
Methods and Results—
We systematically searched Medline for reported cases of late stent thrombosis and very late stent thrombosis published between January 2001 and July 2008.
We restricted our search to Academic Research Consortium–defined definite cases.
We identified 161 cases of late stent thrombosis or very late stent thrombosis from 84 articles (79 from case reports, 61 from registries, and 21 from randomized clinical trials).
Patients had a mean age of 58.
4±13.
4 years, and 88% were male.
A total of 19 cases occurred in patients who were receiving dual antiplatelet therapy at the time of the event.
If patients stopped both antiplatelet agents simultaneously, the median time to event was 7 days.
If patients had previously stopped a thienopyridine with no ill effect and subsequently stopped acetylsalicylic acid, the median time to event was also 7 days from the time of acetylsalicylic acid cessation.
If the thienopyridine was stopped but acetylsalicylic acid was maintained, the median time to event was 122 days.
Among the 48 patients who stopped both agents, 36 cases (75%) occurred within 10 days.
Among the 94 patients who discontinued a thienopyridine but continued acetylsalicylic acid, only 6 cases (6%) occurred within 10 days.
Conclusion—
If acetylsalicylic acid therapy is maintained, short-term discontinuation of a thienopyridine may be relatively safe in patients with drug-eluting stents.
Related Results
3D-printed polymeric bioresorbable stents for cardiovascular applications
3D-printed polymeric bioresorbable stents for cardiovascular applications
(English) Bioresorbable stents (BRS) have been envisioned as a revolution in the treatment of coronary heart disease. Ideally, stents would initially retain sufficient radial stren...
Biodegradable-Polymer or Durable-Polymer Stents in Patients at High Bleeding Risk: A Randomized, Open-Label Clinical Trial
Biodegradable-Polymer or Durable-Polymer Stents in Patients at High Bleeding Risk: A Randomized, Open-Label Clinical Trial
BACKGROUND:
Limited information is available on the comparative efficacy and safety of different stent platforms in patients at high bleeding risk undergoing an abbrevi...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract
Introduction
Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...
The use of drug eluting stents in single and multivessel disease: results from a single centre experience
The use of drug eluting stents in single and multivessel disease: results from a single centre experience
Objective: Drug eluting stents have been shown to reduce the rate of in-stent restenosis in cases where single lesions are treated. The performance of these stents, in patients wit...
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
BackgroundA clinical dilemma exists in patients with CKD, ESKD, and after kidney transplantation, as they face concurrent risks of both thromboembolic and hemorrhagic complications...
In-stent restenosis in the drug-eluting stent era
In-stent restenosis in the drug-eluting stent era
For the last two decades, restenosis has been considered the most significant problem in interventional cardiology. Drug-eluting stents (DES) have reduced rates of restenosis and t...
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Abstract
Introduction
Although the efficacy of PD-L1 blockade has been evaluated in analyses that combine pharmacologically distinct antibodies, the specific efficacy and safety of...
Abstract 16008: Improved Safety and Efficacy of a Novel Dual cRGD- and Everolimus-Coated Coronary Stent Compared to Everolimus-Eluting Stents in the Porcine Coronary Model
Abstract 16008: Improved Safety and Efficacy of a Novel Dual cRGD- and Everolimus-Coated Coronary Stent Compared to Everolimus-Eluting Stents in the Porcine Coronary Model
Background:
Re-endothelialization after drug-eluting stent implantation is delayed. Integrin-binding cyclic Arg-Gly-As p (cRGD) peptide-loaded stents offer potential fo...