Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Safety, efficacy, and maneuverability of a self-propelled capsule endoscope for observation of the human gastrointestinal tract

View through CrossRef
Abstract Background and study aims We developed a self-propelled capsule endoscope that can be controlled from outside the body with real-time observation. To improve the device, we conducted a clinical trial of total gastrointestinal capsule endoscopy in healthy subjects to ascertain whether our first-generation, self-propelled capsule endoscope was safe and effective for observing the entire human gastrointestinal tract. Patients and methods After adequate gastrointestinal pretreatment, five healthy subjects were instructed to swallow a self-propelling capsule endoscope and the safety of a complete gastrointestinal capsule endoscopy with this device was assessed. We also investigated basic problems associated with complete gastrointestinal capsule endoscopy. Results No adverse effects of the magnetic field were identified in any of the subjects. No mucosal damage was noted in any of the subjects with the use of our first-generation, self-propelling capsule endoscope. We found that it took longer than expected to observe the stomach; the view was compromised by the swallowed saliva. The pylorus was extremely difficult to navigate, and the endoscope’s fin sometimes got caught in the folds of the small intestine and colon. Conclusions To resolve the problems associated with the existing self-propelling capsule endoscope, it may be necessary to not only improve the capsule endoscopes, but also to control the environment within the gastrointestinal tract with medications and other means. Our results could guide other researchers in developing capsule endoscopes controllable from outside the body, thus allowing real-time observation.
Title: Safety, efficacy, and maneuverability of a self-propelled capsule endoscope for observation of the human gastrointestinal tract
Description:
Abstract Background and study aims We developed a self-propelled capsule endoscope that can be controlled from outside the body with real-time observation.
To improve the device, we conducted a clinical trial of total gastrointestinal capsule endoscopy in healthy subjects to ascertain whether our first-generation, self-propelled capsule endoscope was safe and effective for observing the entire human gastrointestinal tract.
Patients and methods After adequate gastrointestinal pretreatment, five healthy subjects were instructed to swallow a self-propelling capsule endoscope and the safety of a complete gastrointestinal capsule endoscopy with this device was assessed.
We also investigated basic problems associated with complete gastrointestinal capsule endoscopy.
Results No adverse effects of the magnetic field were identified in any of the subjects.
No mucosal damage was noted in any of the subjects with the use of our first-generation, self-propelling capsule endoscope.
We found that it took longer than expected to observe the stomach; the view was compromised by the swallowed saliva.
The pylorus was extremely difficult to navigate, and the endoscope’s fin sometimes got caught in the folds of the small intestine and colon.
Conclusions To resolve the problems associated with the existing self-propelling capsule endoscope, it may be necessary to not only improve the capsule endoscopes, but also to control the environment within the gastrointestinal tract with medications and other means.
Our results could guide other researchers in developing capsule endoscopes controllable from outside the body, thus allowing real-time observation.

Related Results

The Burden of Road Traffic Injuries: A Global Perspective
The Burden of Road Traffic Injuries: A Global Perspective
Introduction     Road Traffic Injury (RTI) pose a significant health challenge. It represents the eighth leading cause of death globally, prompting the UN to designate 2011-2020 as...
Endoscope Disinfection with Acid Electrolyzed Water
Endoscope Disinfection with Acid Electrolyzed Water
Abstract:Reports of endoscope‐mediated infectious diseases have been increasing. In order to investigate the usefulness of acid electrolyzed water for endoscope disinfection, a tes...
Is a Fitbit a Diary? Self-Tracking and Autobiography
Is a Fitbit a Diary? Self-Tracking and Autobiography
Data becomes something of a mirror in which people see themselves reflected. (Sorapure 270)In a 2014 essay for The New Yorker, the humourist David Sedaris recounts an obsession spu...
The iArmS Robotic Armrest Prolongs Endoscope Lens–Wiping Intervals in Endoscopic Sinus Surgery
The iArmS Robotic Armrest Prolongs Endoscope Lens–Wiping Intervals in Endoscopic Sinus Surgery
Objective. Fouling of the endoscope lens is a major problem in endoscopic sinus surgery (ESS). We examined whether the use of the intelligent arm support system (iArmS), a robotic ...
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Abstract Introduction Although the efficacy of PD-L1 blockade has been evaluated in analyses that combine pharmacologically distinct antibodies, the specific efficacy and safety of...
Inhibitory effect of capsule on natural transformation of Streptococcus pneumoniae
Inhibitory effect of capsule on natural transformation of Streptococcus pneumoniae
ABSTRACT The capsule ofStreptococcus pneumoniae(Spn) is highly heterogeneous based on expression of distinct polysaccharides.Spntransformation, controlled by the Com regulon, has b...
Endoscopy for in-vivo two photon fluoresence imaging of neurons in the hippocampus and cortex of mice
Endoscopy for in-vivo two photon fluoresence imaging of neurons in the hippocampus and cortex of mice
Développements endoscopiques pour l’imagerie par fluorescence à deux photons in vivo des neurones crâniens de la souris Les neuroscientifiques ont de plus en plus r...

Back to Top