Effects of Recycled Concrete on Structural Behavior of Composite Beams with Y-Rib Shear Connectors

View through CrossRef
This study inspects the structural behavior of composite steel concrete beams connected together by Y-Rib shear connectors using recycled concrete. The main method involves using stud shear connectors with normal concrete. By comparing the structural performance of Y-Rib shear connectors with conventional stud shear connectors, the study aims to determine the benefit of using this type of connector with recycled concrete. Improved results in terms of maximum load-bearing capacity before failure and maintaining structural integrity until failure would indicate a viable solution to the sliding issue seen in traditional composite beams. Regardless of challenges in acquiring traditional shear connectors, the study also explores an alternative: 20mm diameter reinforcing bars. Although this falls outside the primary research scope, the main focus remains on the behavior of composite beams connected by Y-shaped shear connectors with recycled concrete. The investigation encompasses 18 shear connector types, divided into two groups: 9 models with normal coarse aggregate concrete (35.17 MPa) and 9 models with recycled coarse aggregate concrete (33.48 MPa) to determine the benefit of recycled aggregate concrete usage.
Title: Effects of Recycled Concrete on Structural Behavior of Composite Beams with Y-Rib Shear Connectors
Description:
This study inspects the structural behavior of composite steel concrete beams connected together by Y-Rib shear connectors using recycled concrete.
The main method involves using stud shear connectors with normal concrete.
By comparing the structural performance of Y-Rib shear connectors with conventional stud shear connectors, the study aims to determine the benefit of using this type of connector with recycled concrete.
Improved results in terms of maximum load-bearing capacity before failure and maintaining structural integrity until failure would indicate a viable solution to the sliding issue seen in traditional composite beams.
Regardless of challenges in acquiring traditional shear connectors, the study also explores an alternative: 20mm diameter reinforcing bars.
Although this falls outside the primary research scope, the main focus remains on the behavior of composite beams connected by Y-shaped shear connectors with recycled concrete.
The investigation encompasses 18 shear connector types, divided into two groups: 9 models with normal coarse aggregate concrete (35.
17 MPa) and 9 models with recycled coarse aggregate concrete (33.
48 MPa) to determine the benefit of recycled aggregate concrete usage.

Related Results

Are Cervical Ribs Indicators of Childhood Cancer? A Narrative Review
Are Cervical Ribs Indicators of Childhood Cancer? A Narrative Review
Abstract A cervical rib (CR), also known as a supernumerary or extra rib, is an additional rib that forms above the first rib, resulting from the overgrowth of the transverse proce...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Dynamic Characteristics Analysis of Three-Layer Steel–Concrete Composite Beams
Dynamic Characteristics Analysis of Three-Layer Steel–Concrete Composite Beams
The dynamic behavior of three-layer composite beams, consisting of concrete slabs and steel beams, is influenced by the structural configuration of each layer as well as the shear ...
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature  Review Anna Tri Wahyuni1), Masfuri2),  Liya Arista3)1,2,3 Fakultas Ilmu Keperawatan Univers...
Far Posterior Approach for Rib Fracture Fixation
Far Posterior Approach for Rib Fracture Fixation
Background: The present video article describes the far posterior or paraspinal approach to posterior rib fractures. This approach is utilized to optimize visualization...
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Experimental and theoretical study on shear performance of T-shaped and bulb flat shear connectors in composite structures
Experimental and theoretical study on shear performance of T-shaped and bulb flat shear connectors in composite structures
This study investigates the mechanical performance and theoretical design methods of T-shaped and bulb flat shear connectors in large-scale steel-concrete composite structures. The...
EXPERIMENTAL INVESTIGATION ON THE SHEAR RESISTANCE OF I-SHAPED PERFORATED CONNECTORS IN COMPOSITE BEAMS
EXPERIMENTAL INVESTIGATION ON THE SHEAR RESISTANCE OF I-SHAPED PERFORATED CONNECTORS IN COMPOSITE BEAMS
Introduction: Steel-concrete composite girders have been widely used in bridges, with the stability of the interface being crucial. Shear connectors and reinforced concrete slabs p...

Back to Top