Javascript must be enabled to continue!
Determination of adenine by chronopotentiometric stripping analysis with nafion‐modified electrode
View through CrossRef
AbstractThe determination of adenine by chronopotentiometric stripping analysis with Nafion‐modified electrode is reported. Various conditions for the determination of adenine were explored. In the Britton‐Robinson (BR) buffer solution (pH 3.3), preconcentration was carried out at −0.2 V (vs. SCE) for 90 seconds by chronopotentiometric stripping analysis. The peak height was proportional to the adenine concentration between 2.5 × 10−7 and 8.0 × 10−6 mol/L. For 10 repetitive measurements, the relative standard deviation for 5 × 10−6 mol/L, adenine was 2.2%. The method was fairly free of interference, and the results of real samples were satisfactory.
Title: Determination of adenine by chronopotentiometric stripping analysis with nafion‐modified electrode
Description:
AbstractThe determination of adenine by chronopotentiometric stripping analysis with Nafion‐modified electrode is reported.
Various conditions for the determination of adenine were explored.
In the Britton‐Robinson (BR) buffer solution (pH 3.
3), preconcentration was carried out at −0.
2 V (vs.
SCE) for 90 seconds by chronopotentiometric stripping analysis.
The peak height was proportional to the adenine concentration between 2.
5 × 10−7 and 8.
0 × 10−6 mol/L.
For 10 repetitive measurements, the relative standard deviation for 5 × 10−6 mol/L, adenine was 2.
2%.
The method was fairly free of interference, and the results of real samples were satisfactory.
Related Results
Nafion/Quercetin/Graphene Composite-Modified Glassy Electrode for Selective and Sensitive Detection of Dopamine
Nafion/Quercetin/Graphene Composite-Modified Glassy Electrode for Selective and Sensitive Detection of Dopamine
Glassy carbon electrode (GCE) was modified using graphene (G), quercetin (Qu) and Nafion in this sequence to fabricate Nafion-Qu-G composite-modified GCE (Nafion/Qu/G/GCE). The as-...
Nafion Based Two Electrode CO Sensor
Nafion Based Two Electrode CO Sensor
The aim of this work is to determine the optimal platinum loading for the preparation of membrane-based electrochemical sensors for carbon monoxide detection. Platinum is a require...
Trace Mercury Ion Detection Sensor Employing SnO2/Rgo Nanocomposites Modified Electrode
Trace Mercury Ion Detection Sensor Employing SnO2/Rgo Nanocomposites Modified Electrode
Introduction
Heavy metal pollution seriously affects human health. Mercury is one of the most hazardous pollution, it has been accum...
Mechanism of Adenine Inhibition in Adenine-Sensitive Mutants of
Salmonella typhimurium
Mechanism of Adenine Inhibition in Adenine-Sensitive Mutants of
Salmonella typhimurium
Dalal, Fram
R. (University of Pennsylvania, Philadelphia),
Ronald E. Gots, and Joseph S. Gots
. Mechanism of adenine inhibition in adenine-sensi...
Sensitive Determination of Rutin Using a Nafion/PMB/Graphene Composite-Modified Glassy Electrode
Sensitive Determination of Rutin Using a Nafion/PMB/Graphene Composite-Modified Glassy Electrode
A novel Nafion/PMB/G/GCE was prepared by firstly electro-polymerization of MB to G/GCE and then coating Nafion on PMB/G/GCE. The as-prepared modified electrode combining the advant...
To evaluate the outcome of varicose vein surgery with and without venous stripping
To evaluate the outcome of varicose vein surgery with and without venous stripping
Aim: The aim of this study to evaluate the outcome of varicose vein surgery with and without venous stripping.Material and methods: This research covered 100 varicose vein operatio...
ADENINE NUCLEOTIDE-INDUCED CONTRACTION OF THE INNER MITOCHONDRIAL MEMBRANE
ADENINE NUCLEOTIDE-INDUCED CONTRACTION OF THE INNER MITOCHONDRIAL MEMBRANE
In bovine heart mitochondria bongkrekic acid at concentrations as low as about 4 nmol/mg protein (a) completely inhibits phosphorylation of exogenous adenosine diphosphate (ADP) an...
Urushi/Nafion Hybrid Membranes for an All‐Vanadium Redox Flow Battery
Urushi/Nafion Hybrid Membranes for an All‐Vanadium Redox Flow Battery
AbstractAn urushi/Nafion hybrid membrane is prepared via a thermal in situ crosslinking reaction of natural urushiol to reduce the crossover of vanadium ions in an all vanadium red...

