Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Impact of an Ultraviolet Reactor on the Improvement of Air Quality Leaving a Direct Evaporative Cooler

View through CrossRef
The purpose of this study is to improve microbial air quality by improving water quality, particularly concerning microbiological aspects, by applying an ultraviolet water purifier system to a direct evaporative cooling (DEC) system. A direct evaporative cooler is an air cooling technique that uses the evaporation of water. Most DECs recirculate water to reduce water use. Evaporative cooling pads and water are biologically contaminated by recirculating water. This contamination can develop into air contamination and cause respiratory illnesses in occupants. It is necessary to use sterilized water in a DEC to prevent respiratory diseases and maintain air quality. In this study, we examine whether improvements in water quality in a DEC affect air quality by dividing experiments into a control group (Control) and a treated group (UV-treated). In the control group, the degree of contamination was measured when a DEC operated for four weeks without ultraviolet water treatment. In UV-treated, the degree of contamination was measured when UV water treatment was applied to a DEC for four weeks. In both Control and UV-treated, microbes were sampled from the water, the evaporative cooling pad surface, and the DEC inlet and outlet air samples in order to compare the levels of contamination. The surface was measured once at four points, and the air was measured four times at two points. A comparison of the two experiments indicated that the degree of microbial contamination of water and air was significantly reduced in the UV-treated group when compared to that in the control group. When the pollution degree of the evaporative cooling pad was compared to the degree of air pollution, it was difficult to obtain a correlation between the two factors, although the results confirmed that the contamination of the evaporative cooling pad caused water pollution. Therefore, it is necessary to operate a water treatment system to maintain the clean air in DECs.
Title: Impact of an Ultraviolet Reactor on the Improvement of Air Quality Leaving a Direct Evaporative Cooler
Description:
The purpose of this study is to improve microbial air quality by improving water quality, particularly concerning microbiological aspects, by applying an ultraviolet water purifier system to a direct evaporative cooling (DEC) system.
A direct evaporative cooler is an air cooling technique that uses the evaporation of water.
Most DECs recirculate water to reduce water use.
Evaporative cooling pads and water are biologically contaminated by recirculating water.
This contamination can develop into air contamination and cause respiratory illnesses in occupants.
It is necessary to use sterilized water in a DEC to prevent respiratory diseases and maintain air quality.
In this study, we examine whether improvements in water quality in a DEC affect air quality by dividing experiments into a control group (Control) and a treated group (UV-treated).
In the control group, the degree of contamination was measured when a DEC operated for four weeks without ultraviolet water treatment.
In UV-treated, the degree of contamination was measured when UV water treatment was applied to a DEC for four weeks.
In both Control and UV-treated, microbes were sampled from the water, the evaporative cooling pad surface, and the DEC inlet and outlet air samples in order to compare the levels of contamination.
The surface was measured once at four points, and the air was measured four times at two points.
A comparison of the two experiments indicated that the degree of microbial contamination of water and air was significantly reduced in the UV-treated group when compared to that in the control group.
When the pollution degree of the evaporative cooling pad was compared to the degree of air pollution, it was difficult to obtain a correlation between the two factors, although the results confirmed that the contamination of the evaporative cooling pad caused water pollution.
Therefore, it is necessary to operate a water treatment system to maintain the clean air in DECs.

Related Results

Performance Analysis of Direct Stage, In-Direct Stage and Two-Stage Evaporative Air Cooler
Performance Analysis of Direct Stage, In-Direct Stage and Two-Stage Evaporative Air Cooler
Evaporative coolers are used in various areas especially in dry, hot climates in weather. This research focus on the theoretical and experimental result of the evaporative air cool...
Performance Optimization of Air Cooler Using Peltier and SEPIC Converter as Temperature Control
Performance Optimization of Air Cooler Using Peltier and SEPIC Converter as Temperature Control
Air cooler has an evaporative mode that is used to get a cooler temperature output than without using evaporative mode. The evaporative cooling process involves water that is coole...
Advancements and Performance of Evaporative Cooling Technologies: Applications, Benefits, and Future Prospects
Advancements and Performance of Evaporative Cooling Technologies: Applications, Benefits, and Future Prospects
Evaporative cooling is a widely adopted technology for various applications, including industrial processes, HVAC systems, building cooling, and microclimate regulation. It is know...
Theoretical Analysis of Geometrically Modified Dew Point Evaporative Cooler
Theoretical Analysis of Geometrically Modified Dew Point Evaporative Cooler
Abstract Human thermal comfort being one of major aspect of increasing demand of energy consumption for heating, ventilation and air conditioning (HVAC) sector. The ...
A Review on Design and Development of 360° Evaporative Air Cooler
A Review on Design and Development of 360° Evaporative Air Cooler
This review presents a detailed case study on evaporative coolers, a widely-used technology for air conditioning in hot and dry climates. It is also known as swamp cooler. Evaporat...
ANALISIS PENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM
ANALISIS PENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM
ANALISISPENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM POST REACTOR SCRAM CONTROL RODS POSITION ADJUSTMENT ANALYSIS FOR THE IN...
Analisis Lubricant Oil Cooler pada Main Engine Di KM. Vertikal
Analisis Lubricant Oil Cooler pada Main Engine Di KM. Vertikal
Lubrication is one aspect that must be paid attention to, remembering that if there is a delay in lubrication or imperfect lubrication, it will result in damage to the parts that r...