Introduction: Different polymers used in artificial tear formulations influence their physical properties, such as viscosity and pH, hence affecting their bioavailability. There is limited data available from manufacturers specifying the physical properties of artificial tears, even though these data can contribute to their efficacyand effectiveness.
Purpose: The aim of this study was to evaluate 18 artificial tears available in the Malaysian market based on their physical properties.
Methodology: Viscosity and pH of 18 artificial tears were evaluated using rheometer and compact pH-meter, respectively, at standard room temperature (25°C). The amount of fluid used for both tests of each artificial tear was standardised using micropipette. The Kruskal-Wallis test was employed to compare the viscosity median between the three groups (low, medium, and high viscosity) of artificial tears, while the independent t-test was used to compare the pH between preservative and non-preservative artificial tears. A p-value of 0.05 was set as the level of significance.
Results: The mean viscosity for all 18 artificial tears was 12.05 cP ± 10.21 within a range of 0.55 cP to 34.49 cP. There was a significant difference observed in viscosity between low- (n = 7), median- (n = 8), and high- (n = 3) viscosity groups, χ2(2) = 14.474, p = 0.001. The mean pH for all 18 artificial tears was 7.21 ± 0.43, with a range of 6.19 to 7.85. pH for preservative artificial tears was slightly alkaline compared to non-preservative artificial tears (7.26 ± 0.47 vs 7.14 ± 0.38, respectively).
Conclusion: Rheological findings indicated that different formulations of artificial tears have different viscosities, with most artificial tears falling within the recommended values. There was no difference in terms of pH between preservative and non-preservative artificial tears.
Title: Evaluation of 18 artificial tears based on viscosity and pH
Description:
Introduction: Different polymers used in artificial tear formulations influence their physical properties, such as viscosity and pH, hence affecting their bioavailability.
There is limited data available from manufacturers specifying the physical properties of artificial tears, even though these data can contribute to their efficacyand effectiveness.
Purpose: The aim of this study was to evaluate 18 artificial tears available in the Malaysian market based on their physical properties.
Methodology: Viscosity and pH of 18 artificial tears were evaluated using rheometer and compact pH-meter, respectively, at standard room temperature (25°C).
The amount of fluid used for both tests of each artificial tear was standardised using micropipette.
The Kruskal-Wallis test was employed to compare the viscosity median between the three groups (low, medium, and high viscosity) of artificial tears, while the independent t-test was used to compare the pH between preservative and non-preservative artificial tears.
A p-value of 0.
05 was set as the level of significance.
Results: The mean viscosity for all 18 artificial tears was 12.
05 cP ± 10.
21 within a range of 0.
55 cP to 34.
49 cP.
There was a significant difference observed in viscosity between low- (n = 7), median- (n = 8), and high- (n = 3) viscosity groups, χ2(2) = 14.
474, p = 0.
001.
The mean pH for all 18 artificial tears was 7.
21 ± 0.
43, with a range of 6.
19 to 7.
85.
pH for preservative artificial tears was slightly alkaline compared to non-preservative artificial tears (7.
26 ± 0.
47 vs 7.
14 ± 0.
38, respectively).
Conclusion: Rheological findings indicated that different formulations of artificial tears have different viscosities, with most artificial tears falling within the recommended values.
There was no difference in terms of pH between preservative and non-preservative artificial tears.
Related Results
Frequency of anterolateral ligament tears and ramp lesions in patients with anterior cruciate ligament tears and associated injuries indicative for these lesions—a retrospective MRI analysis
Frequency of anterolateral ligament tears and ramp lesions in patients with anterior cruciate ligament tears and associated injuries indicative for these lesions—a retrospective MRI analysis
Abstract
Objectives
To assess the frequency of anterolateral ligament (ALL) tears and ramp lesions (RL) detected with MRI...
New Compositional Models for Calculating Viscosity of Crude Oils
New Compositional Models for Calculating Viscosity of Crude Oils
Abstract
Crude oil viscosity is an important physical property that controls and influences the flow of oil through porous media and pipelines. Hence, it is the b...
VAGINAL BIRTH TRAUMA AND PRIMIPARITY; EXPERIENCE AT A TERTIARY CARE HOSPITAL
VAGINAL BIRTH TRAUMA AND PRIMIPARITY; EXPERIENCE AT A TERTIARY CARE HOSPITAL
Objective: To determine the effects of perineal tears during vaginal birth in primiparouswomenMethodology: This Cross-Sectional Study was conducted at the Department of Obstetrics&...
Combined Meniscus Repair and Anterior Cruciate Ligament Reconstruction
Combined Meniscus Repair and Anterior Cruciate Ligament Reconstruction
Abstract
Meniscal tear patterns associated with anterior cruciate ligament (ACL) tears, such as root tears and ramp lesions are common but less easily recognize...
Subclassification of second-degree tears at delivery: creation and reported outcomes
Subclassification of second-degree tears at delivery: creation and reported outcomes
Abstract
Background
Perineal tears at delivery are common. The current WHO classification system compacts all the varying...
Subclassification of second-degree tears at delivery: creation and reported outcomes
Subclassification of second-degree tears at delivery: creation and reported outcomes
Abstract
Background:
Perineal tears at delivery are common. The current WHO classification system compacts all the varying extents of second-degree tears into one code. Som...
A Model of Positive Tears
A Model of Positive Tears
Although several scholars acknowledge the existence of tears of joy, there is little systematic theoretical or empirical evidence on how positive tears are experienced, what elicit...
Perineal Tears; Frequency, Severity and Risk factors in a Tertiary Care Hospital
Perineal Tears; Frequency, Severity and Risk factors in a Tertiary Care Hospital
Objective: To observe the frequency, severity, and risk factors of perineal tears during vaginal delivery in a tertiary care hospital.
Methodology: This was a cohort study of wom...