Javascript must be enabled to continue!
An indentation depth—force sensing wheeled probe for abnormality identification during minimally invasive surgery
View through CrossRef
This paper presents a novel wheeled probe for the purpose of aiding a surgeon in soft tissue abnormality identification during minimally invasive surgery (MIS), compensating the loss of haptic feedback commonly associated with MIS. Initially, a prototype for validating the concept was developed. The wheeled probe consists of an indentation depth sensor employing an optic fibre sensing scheme and a force/torque sensor. The two sensors work in unison, allowing the wheeled probe to measure the tool—tissue interaction force and the rolling indentation depth concurrently. The indentation depth sensor was developed and initially tested on a homogenous silicone phantom representing a good model for a soft tissue organ; the results show that the sensor can accurately measure the indentation depths occurring while performing rolling indentation, and has good repeatability. To validate the ability of the wheeled probe to identify abnormalities located in the tissue, the device was tested on a silicone phantom containing embedded hard nodules. The experimental data demonstrate that recording the tissue reaction force as well as rolling indentation depth signals during rolling indentation, the wheeled probe can rapidly identify the distribution of tissue stiffness and cause the embedded hard nodules to be accurately located.
Title: An indentation depth—force sensing wheeled probe for abnormality identification during minimally invasive surgery
Description:
This paper presents a novel wheeled probe for the purpose of aiding a surgeon in soft tissue abnormality identification during minimally invasive surgery (MIS), compensating the loss of haptic feedback commonly associated with MIS.
Initially, a prototype for validating the concept was developed.
The wheeled probe consists of an indentation depth sensor employing an optic fibre sensing scheme and a force/torque sensor.
The two sensors work in unison, allowing the wheeled probe to measure the tool—tissue interaction force and the rolling indentation depth concurrently.
The indentation depth sensor was developed and initially tested on a homogenous silicone phantom representing a good model for a soft tissue organ; the results show that the sensor can accurately measure the indentation depths occurring while performing rolling indentation, and has good repeatability.
To validate the ability of the wheeled probe to identify abnormalities located in the tissue, the device was tested on a silicone phantom containing embedded hard nodules.
The experimental data demonstrate that recording the tissue reaction force as well as rolling indentation depth signals during rolling indentation, the wheeled probe can rapidly identify the distribution of tissue stiffness and cause the embedded hard nodules to be accurately located.
Related Results
ADVANCES AND CHALLENGES IN MINIMALLY INVASIVE SURGERY FOR THE TREATMENT OF HERNIAS
ADVANCES AND CHALLENGES IN MINIMALLY INVASIVE SURGERY FOR THE TREATMENT OF HERNIAS
Minimally invasive surgery has revolutionized the treatment of various medical conditions, offering significant benefits in terms of recovery and fewer complications. In the field ...
Calculation of the depth of rope-tightening soft material and analysis of its relationship with the tightening force
Calculation of the depth of rope-tightening soft material and analysis of its relationship with the tightening force
To analyze the relationship between the tension force of a rope and the bundled material's indentation, a model of tightening by rope for soft material was designed for testing. By...
Evaluation of the (Baha) technique of scleral indentation using a self-retained scleral indenter during vitrectomy surgery: a randomized trial
Evaluation of the (Baha) technique of scleral indentation using a self-retained scleral indenter during vitrectomy surgery: a randomized trial
Abstract
Aims
The current study compared a novel technique of scleral indentation using the self-retaining Leyla retractor to the conventional sc...
063. ROBOTIC ASSISTED MIMINALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY VERSUS CONVENTIONAL MINIMALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY
063. ROBOTIC ASSISTED MIMINALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY VERSUS CONVENTIONAL MINIMALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY
Abstract
Background
Minimally invasive technique for esophagectomy has emerged as the standard of care for resectable esophageal...
Early Independent Wheeled Mobility in Children with Cerebral Palsy: A Norwegian Population-Based Registry Study
Early Independent Wheeled Mobility in Children with Cerebral Palsy: A Norwegian Population-Based Registry Study
Background: The aim was to explore independent wheeled mobility in children with CP, and identify predictors of early independent wheeled mobility and changes over time across birt...
Clinical Effectiveness of Minimally Invasive Surgery on Spinal Trauma
Clinical Effectiveness of Minimally Invasive Surgery on Spinal Trauma
AIM: Minimally invasive spinal trauma surgery includes percutaneous pedicle screw fixation and miniature open anterolateral retractor-based approaches, which can improve surgical o...
Surgical Management of Spinal Metastases: Balancing Oncologic Control and Neurological Function
Surgical Management of Spinal Metastases: Balancing Oncologic Control and Neurological Function
Objective: To compare the outcomes of traditional and minimally invasive surgery in the treatment of spinal metastases, focusing on pain relief, neurological function, and oncologi...
Oncological outcomes in minimally invasive gastric cancer surgery
Oncological outcomes in minimally invasive gastric cancer surgery
In the first part of this dissertation an assessment was made on current available
evidence regarding outcomes in minimally invasive gastrectomy in comparison to open
gastrectomy. ...

