Javascript must be enabled to continue!
Aptamer-Based Electrochemical Biosensors for the Detection of Salmonella: A Scoping Review
View through CrossRef
The development of rapid, accurate, and efficient detection methods for Salmonella can significantly control the outbreak of salmonellosis that threatens global public health. Despite the high sensitivity and specificity of the microbiological, nucleic-acid, and immunological-based methods, they are impractical for detecting samples outside of the laboratory due to the requirement for skilled individuals and sophisticated bench-top equipment. Ideally, an electrochemical biosensor could overcome the limitations of these detection methods since it offers simplicity for the detection process, on-site quantitative analysis, rapid detection time, high sensitivity, and portability. The present scoping review aims to assess the current trends in electrochemical aptasensors to detect and quantify Salmonella. This review was conducted according to the latest Preferred Reporting Items for Systematic review and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) guidelines. A literature search was performed using aptamer and Salmonella keywords in three databases: PubMed, Scopus, and Springer. Studies on electrochemical aptasensors for detecting Salmonella published between January 2014 and January 2022 were retrieved. Of the 787 studies recorded in the search, 29 studies were screened for eligibility, and 15 studies that met the inclusion criteria were retrieved for this review. Information on the Salmonella serovars, targets, samples, sensor specification, platform technologies for fabrication, electrochemical detection methods, limit of detection (LoD), and detection time was discussed to evaluate the effectiveness and limitations of the developed electrochemical aptasensor platform for the detection of Salmonella. The reported electrochemical aptasensors were mainly developed to detect Salmonella enterica Typhimurium in chicken meat samples. Most of the developed electrochemical aptasensors were fabricated using conventional electrodes (13 studies) rather than screen-printed electrodes (SPEs) (two studies). The developed aptasensors showed LoD ranges from 550 CFU/mL to as low as 1 CFU/mL within 5 min to 240 min of detection time. The promising detection performance of the electrochemical aptasensor highlights its potential as an excellent alternative to the existing detection methods. Nonetheless, more research is required to determine the sensitivity and specificity of the electrochemical sensing platform for Salmonella detection, particularly in human clinical samples, to enable their future use in clinical practice.
Title: Aptamer-Based Electrochemical Biosensors for the Detection of Salmonella: A Scoping Review
Description:
The development of rapid, accurate, and efficient detection methods for Salmonella can significantly control the outbreak of salmonellosis that threatens global public health.
Despite the high sensitivity and specificity of the microbiological, nucleic-acid, and immunological-based methods, they are impractical for detecting samples outside of the laboratory due to the requirement for skilled individuals and sophisticated bench-top equipment.
Ideally, an electrochemical biosensor could overcome the limitations of these detection methods since it offers simplicity for the detection process, on-site quantitative analysis, rapid detection time, high sensitivity, and portability.
The present scoping review aims to assess the current trends in electrochemical aptasensors to detect and quantify Salmonella.
This review was conducted according to the latest Preferred Reporting Items for Systematic review and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) guidelines.
A literature search was performed using aptamer and Salmonella keywords in three databases: PubMed, Scopus, and Springer.
Studies on electrochemical aptasensors for detecting Salmonella published between January 2014 and January 2022 were retrieved.
Of the 787 studies recorded in the search, 29 studies were screened for eligibility, and 15 studies that met the inclusion criteria were retrieved for this review.
Information on the Salmonella serovars, targets, samples, sensor specification, platform technologies for fabrication, electrochemical detection methods, limit of detection (LoD), and detection time was discussed to evaluate the effectiveness and limitations of the developed electrochemical aptasensor platform for the detection of Salmonella.
The reported electrochemical aptasensors were mainly developed to detect Salmonella enterica Typhimurium in chicken meat samples.
Most of the developed electrochemical aptasensors were fabricated using conventional electrodes (13 studies) rather than screen-printed electrodes (SPEs) (two studies).
The developed aptasensors showed LoD ranges from 550 CFU/mL to as low as 1 CFU/mL within 5 min to 240 min of detection time.
The promising detection performance of the electrochemical aptasensor highlights its potential as an excellent alternative to the existing detection methods.
Nonetheless, more research is required to determine the sensitivity and specificity of the electrochemical sensing platform for Salmonella detection, particularly in human clinical samples, to enable their future use in clinical practice.
Related Results
Development of an aptamer-based rapid diagnostic assay for
Salmonella
detection using whole-cell SELEX technique
Development of an aptamer-based rapid diagnostic assay for
Salmonella
detection using whole-cell SELEX technique
ABSTRACT
Rapid and accurate detection of
Salmonella
i...
Novel Strategies for Gold Nanoparticle Based Aptamer Selection
Novel Strategies for Gold Nanoparticle Based Aptamer Selection
<p><strong>While many successful biotechnological tools that enable the sensing of compounds within environmental and biological systems have been produced to date, the...
How human serum albuminâselective DNA aptamer binds to bovine and canine serum albumins
How human serum albuminâselective DNA aptamer binds to bovine and canine serum albumins
AbstractSerum albumin (SA) is the most abundant carrier protein in blood. SA carries a diverse range of nutrients, drugs, and metal ions. It has wide clinical and biochemical appli...
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
BACKGROUND
Access to potable drinking water and sufficient sanitation continues to be an urgent global concern, particularly in developing regions where con...
Laboratory Epidemiology of
Salmonella
Infections and Multi-Drug Resistance Profiles in Nigeria: Barriers, Challenges and Proposed Solutions
Laboratory Epidemiology of
Salmonella
Infections and Multi-Drug Resistance Profiles in Nigeria: Barriers, Challenges and Proposed Solutions
Abstract
Background
National surveillance data on
Salmonella
antim...
Allosteric Ligand-Aptamer Complexes Orchestrate Supramolecular or Transient Catalytic, Transcription and Fibrinogenesis Processes
Allosteric Ligand-Aptamer Complexes Orchestrate Supramolecular or Transient Catalytic, Transcription and Fibrinogenesis Processes
Allosteric regulation, the modulation of biological macromolecular function through binding of molecules at distant sites distinct from the active site, is a fundamental principle ...
Accelerated Discovery of Aptamer Beacons via Massively Parallel Screening
Accelerated Discovery of Aptamer Beacons via Massively Parallel Screening
Abstract
Aptamer beacons are unimolecular probes that undergo a reversible conformational change upon target binding, making them a promising tool for the real-time...
From Enzymatic Dopamine Biosensors to OECT Biosensors of Dopamine
From Enzymatic Dopamine Biosensors to OECT Biosensors of Dopamine
Neurotransmitters are an important category of substances used inside the nervous system, whose detection with biosensors has been seriously addressed in the last decades. Dopamine...

