Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

SYNTHESIS OF QUATERNIZED THIAZOLOQUINAZOLINIUM TRIIODIDE AND ITS APPLICATION AS AN ACTIVE SUBSTANCE FOR POTENTIOMETRIC SENSOR

View through CrossRef
For the first time, the synthesis, isolation, and identification of angular triiodide, 1,2,4,5-tetrahydro-4-ethyl-1-(iodomethyl)-1-methyl-5-oxothiazolo[3,2-a]quinazolin-10-ium, have been achieved. The formation of the triiodide was confirmed by elemental analysis, and its structure was approved by NMR spectra containing signals from the fused thiazolonine ring. The cyclization process was confirmed by the change in signal multiplicity from singlets (thioether) to doublets (thiazole) and a shift to a weaker field in the spectrum of the methyl group from 1.83 ppm to 2.15 ppm. Optimal reaction conditions for the synthesis of thiazolochinazolinium triiodide were found using a double excess of iodine in chloroform at room temperature for 24 hours, yielding 84%. The obtained thiazolochinazolinium triiodide product was utilized as an active substance for a PVC plasticized triiodide selective potentiometric sensor. The sensor exhibited a super-Nernstian response of 75 mV/pC with a detection limit of 5 10-6 mol/L I3- and a lifetime exceeding 4 months. The pH working range of the sensor was found to be within pH 2-10, with a response time of 15-30 s. The sensor is selective to anions and exhibits some sensitivity to molecular iodine and iodide. The sensor was used as an indicator electrode for the direct potentiometric titration of ascorbic acid using a solution of KI3 in intensely colored fruit juices and vitamin preparations. The accuracy was confirmed by the added-found  method and HPLC analysis.
Title: SYNTHESIS OF QUATERNIZED THIAZOLOQUINAZOLINIUM TRIIODIDE AND ITS APPLICATION AS AN ACTIVE SUBSTANCE FOR POTENTIOMETRIC SENSOR
Description:
For the first time, the synthesis, isolation, and identification of angular triiodide, 1,2,4,5-tetrahydro-4-ethyl-1-(iodomethyl)-1-methyl-5-oxothiazolo[3,2-a]quinazolin-10-ium, have been achieved.
The formation of the triiodide was confirmed by elemental analysis, and its structure was approved by NMR spectra containing signals from the fused thiazolonine ring.
The cyclization process was confirmed by the change in signal multiplicity from singlets (thioether) to doublets (thiazole) and a shift to a weaker field in the spectrum of the methyl group from 1.
83 ppm to 2.
15 ppm.
Optimal reaction conditions for the synthesis of thiazolochinazolinium triiodide were found using a double excess of iodine in chloroform at room temperature for 24 hours, yielding 84%.
The obtained thiazolochinazolinium triiodide product was utilized as an active substance for a PVC plasticized triiodide selective potentiometric sensor.
The sensor exhibited a super-Nernstian response of 75 mV/pC with a detection limit of 5 10-6 mol/L I3- and a lifetime exceeding 4 months.
The pH working range of the sensor was found to be within pH 2-10, with a response time of 15-30 s.
The sensor is selective to anions and exhibits some sensitivity to molecular iodine and iodide.
The sensor was used as an indicator electrode for the direct potentiometric titration of ascorbic acid using a solution of KI3 in intensely colored fruit juices and vitamin preparations.
The accuracy was confirmed by the added-found  method and HPLC analysis.

Related Results

Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Development of Microcontroller Based Potentiometric Transduction Circuit for a Continuous Fluid Level Sensor
Development of Microcontroller Based Potentiometric Transduction Circuit for a Continuous Fluid Level Sensor
This paper presents the development of microcontroller based potentiometric transduction circuit for a continuous fluid level sensor. The purpose system involved the integration be...
Knowledge and perspectives of health care providers towards clients with substance abuse at Solwezi General Hospital in Solwezi District
Knowledge and perspectives of health care providers towards clients with substance abuse at Solwezi General Hospital in Solwezi District
Introduction: Substance abuse is increasingly becoming a public health threat associated with varying health and social implications. Healthcare professionals are crucial in the ma...
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
Potentiometric sensors
Potentiometric sensors
This chapter describes the functioning of potentiometric sensors, how they can be usefully employed, and in which experimental situations. Potentiometric sensors work through the m...
Técnicas de reconstrucción y compensación activa de frentes de onda complejos
Técnicas de reconstrucción y compensación activa de frentes de onda complejos
The continuous improvements of optical design tools and manufacturing technologies of free-form optical elements, allow the creation of new complex-shaped lenses that improve the p...

Back to Top