Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Supraciliary microstent implantation for open-angle glaucoma: multicentre 3-year outcomes

View through CrossRef
Objective To describe the safety and effectiveness of CyPass supraciliary microstent implantation alone in eyes with open-angle glaucoma (OAG) followed up for up to 3 years. Methods and analysis This registry study included subjects with primary or secondary OAG who underwent CyPass Micro-Stent implantation alone at 12 sites in four European countries to reduce intraocular pressure (IOP) and/or use of IOP-lowering medications. The primary safety outcome was the incidence of adverse events. Secondary efficacy outcomes included mean changes from baseline in IOP and IOP-lowering medications. Eyes were subgrouped into those with low (< 21 mm Hg) and high (> 21 mm Hg) baseline IOP. Results This study included 225 eyes of 178 patients, with mean baseline IOP of 22.6 ± 6.7 mm Hg and a mean 2.2 ± 1.2 medications per eye. Common ocular adverse events included device obstruction (10.2%), IOP elevation > 10 mm Hg during follow-up (8.9%), retinal complications (4.4%) and loss of > 2 lines of best-corrected visual acuity (2.7%). Seventy-one eyes (31.6%) required secondary glaucoma surgery, with trabeculectomy (33 eyes) and second microstent implantation (13 eyes) being most common. At months 6–36, mean IOP reductions ranged from 4.4 to 5.1 mm Hg (15.8%–19.5%) and mean medication reductions from 0.2 to 1.2 (9.1%–54.5%). Mean IOP reduction was greater in eyes with higher than lower baseline IOP. Both subgroups showed reductions of 0.5–1.0 medication at 12–18 months. Conclusion CyPass microstent implantation demonstrated a safety profile consistent with other minimally invasive glaucoma surgeries and effectively lowered IOP for up to 3 years in eyes with OAG.
Title: Supraciliary microstent implantation for open-angle glaucoma: multicentre 3-year outcomes
Description:
Objective To describe the safety and effectiveness of CyPass supraciliary microstent implantation alone in eyes with open-angle glaucoma (OAG) followed up for up to 3 years.
Methods and analysis This registry study included subjects with primary or secondary OAG who underwent CyPass Micro-Stent implantation alone at 12 sites in four European countries to reduce intraocular pressure (IOP) and/or use of IOP-lowering medications.
The primary safety outcome was the incidence of adverse events.
Secondary efficacy outcomes included mean changes from baseline in IOP and IOP-lowering medications.
Eyes were subgrouped into those with low (< 21 mm Hg) and high (> 21 mm Hg) baseline IOP.
Results This study included 225 eyes of 178 patients, with mean baseline IOP of 22.
6 ± 6.
7 mm Hg and a mean 2.
2 ± 1.
2 medications per eye.
Common ocular adverse events included device obstruction (10.
2%), IOP elevation > 10 mm Hg during follow-up (8.
9%), retinal complications (4.
4%) and loss of > 2 lines of best-corrected visual acuity (2.
7%).
Seventy-one eyes (31.
6%) required secondary glaucoma surgery, with trabeculectomy (33 eyes) and second microstent implantation (13 eyes) being most common.
At months 6–36, mean IOP reductions ranged from 4.
4 to 5.
1 mm Hg (15.
8%–19.
5%) and mean medication reductions from 0.
2 to 1.
2 (9.
1%–54.
5%).
Mean IOP reduction was greater in eyes with higher than lower baseline IOP.
Both subgroups showed reductions of 0.
5–1.
0 medication at 12–18 months.
Conclusion CyPass microstent implantation demonstrated a safety profile consistent with other minimally invasive glaucoma surgeries and effectively lowered IOP for up to 3 years in eyes with OAG.

Related Results

Childhood glaucoma profile in a Southwestern Ethiopia tertiary care center: a retrospective study
Childhood glaucoma profile in a Southwestern Ethiopia tertiary care center: a retrospective study
Abstract Background Childhood glaucoma is a major cause of childhood blindness worldwide. The profile of childhood glaucoma has not been well characterized in sub-Saharan ...
Genetics of Glaucoma
Genetics of Glaucoma
Abstract Glaucoma is the major cause of blindness worldwide. Primary open‐angle glaucoma (POAG) and angle closure glaucoma (ACG) are the most pr...
Clinical outcomes of Ahmed glaucoma valve implantation in pediatric glaucoma
Clinical outcomes of Ahmed glaucoma valve implantation in pediatric glaucoma
Purpose: To evaluate the outcomes of Ahmed glaucoma valve implantation in refractory primary congenital glaucoma as well as primary procedure in aphakic glaucom...
Trend of glaucoma internal filtration surgeries in a tertiary hospital in China
Trend of glaucoma internal filtration surgeries in a tertiary hospital in China
AIM: To evaluate the trend of glaucoma internal filtration surgeries for inpatients between 2015 and 2021 at the Eye Hospital of Wenzhou Medical University. METHODS: A review of th...
Cross-sectional Survey to Determine the Awareness and Uptake of Glaucoma Surgery
Cross-sectional Survey to Determine the Awareness and Uptake of Glaucoma Surgery
Introduction : This study aimed to determine the awareness and uptake of surgery as a treatment option in patients with glaucoma on medical treatment. ...
Profile of Newly Referred Glaucoma Patients to the Largest Tertiary Eye Care Hospital in Saudi Arabia
Profile of Newly Referred Glaucoma Patients to the Largest Tertiary Eye Care Hospital in Saudi Arabia
Abstract Purpose: To report the profile of newly referred glaucoma patients to the largest tertiary eye care hospital in Saudi Arabia. Patients and Methods: Medical record...

Back to Top