Javascript must be enabled to continue!
Do Capacitively Coupled Electric Fields Accelerate Tibial Stress Fracture Healing?
View through CrossRef
Background
Tibial stress fractures increasingly affect athletes and military recruits, with few known effective management options. Electrical stimulation enhances regular fracture healing, but the effect on stress fractures has not been definitively tested.
Hypothesis
Capacitively coupled electric field stimulation will accelerate tibial stress fracture healing.
Study Design
Randomized controlled trial; Level of evidence, 1.
Methods
Twenty men and 24 women with acute posteromedial tibial stress fractures were referred from local clinicians. Subjects were randomly assigned active or placebo capacitively coupled electric field stimulation to be applied for 15 hours per day until healed, given supplemental calcium, and instructed to rest from provocative training. Healing was confirmed when hopping to 10 cm for 30 seconds could be achieved without pain.
Results
No difference in time to healing was detected between treatment and placebo groups. Women in the treatment group healed more slowly than did the men ( P = .05). Superior treatment compliance was associated with reduced time to healing ( P = .003). Rest noncompliance was associated with increased time to healing ( P = .05).
Conclusion
Whole-group analysis did not detect an effect of capacitively coupled electric field stimulation on tibial stress fracture healing; however, greater device use and less weightbearing loading enhanced the effectiveness of the active device. More severe stress fractures healed more quickly with capacitively coupled electric field stimulation.
Clinical Relevance
Although the use of capacitively coupled electric field stimulation for tibial stress fracture healing may not be efficacious for all, it may be indicated for the more severely injured or elite athlete/recruit whose incentive to return to activity may motivate superior compliance.
Title: Do Capacitively Coupled Electric Fields Accelerate Tibial Stress Fracture Healing?
Description:
Background
Tibial stress fractures increasingly affect athletes and military recruits, with few known effective management options.
Electrical stimulation enhances regular fracture healing, but the effect on stress fractures has not been definitively tested.
Hypothesis
Capacitively coupled electric field stimulation will accelerate tibial stress fracture healing.
Study Design
Randomized controlled trial; Level of evidence, 1.
Methods
Twenty men and 24 women with acute posteromedial tibial stress fractures were referred from local clinicians.
Subjects were randomly assigned active or placebo capacitively coupled electric field stimulation to be applied for 15 hours per day until healed, given supplemental calcium, and instructed to rest from provocative training.
Healing was confirmed when hopping to 10 cm for 30 seconds could be achieved without pain.
Results
No difference in time to healing was detected between treatment and placebo groups.
Women in the treatment group healed more slowly than did the men ( P = .
05).
Superior treatment compliance was associated with reduced time to healing ( P = .
003).
Rest noncompliance was associated with increased time to healing ( P = .
05).
Conclusion
Whole-group analysis did not detect an effect of capacitively coupled electric field stimulation on tibial stress fracture healing; however, greater device use and less weightbearing loading enhanced the effectiveness of the active device.
More severe stress fractures healed more quickly with capacitively coupled electric field stimulation.
Clinical Relevance
Although the use of capacitively coupled electric field stimulation for tibial stress fracture healing may not be efficacious for all, it may be indicated for the more severely injured or elite athlete/recruit whose incentive to return to activity may motivate superior compliance.
Related Results
Proximal Tibial Epiphysiodesis in a Growing Dog
Proximal Tibial Epiphysiodesis in a Growing Dog
Background: It is believed that the inclined tibial plateau angle to be a major cause of cranial cruciate ligament (CCL) rupture, and the treatment of this disease is the tibial p...
Sequential Propagation of Multiple Fractures in Horizontal Wells
Sequential Propagation of Multiple Fractures in Horizontal Wells
ABSTRACT:
Simultaneous fracturing and zipper fracturing of horizontal wells has rapidly evolved to the development of unconventional oil and gas. The fracture int...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...
A Rare Case of Combined Tibial Plateau Fracture with Tibial Tuberosity Avulsion Injury: Case Report Showry Abraham Salikity , Kalyan Deepak Sreenvas , Muni Srikanth Iytha , Vineet Thomas Abraham ,
A Rare Case of Combined Tibial Plateau Fracture with Tibial Tuberosity Avulsion Injury: Case Report Showry Abraham Salikity , Kalyan Deepak Sreenvas , Muni Srikanth Iytha , Vineet Thomas Abraham ,
Introduction: Avulsion fracture of the tibial tuberosity is a rare orthopedic injury, predominantly affecting adolescents but seldom seen in the adult population. Lateral tibial pl...
Technique of Tibial Tuberosity Transposition and Advancement (TTTA) With Use of TTA-Maquet Cage-Only in Dog
Technique of Tibial Tuberosity Transposition and Advancement (TTTA) With Use of TTA-Maquet Cage-Only in Dog
Background: The most common conditions that compromise the stifle joint in dogs are medial patellar luxation (MPL) and cranial cruciate ligament (CCL) rupture. Surgical procedures ...
Fracture Modelling Using Seismic Based Fracture Intensity Volume, a Case Study in Middle East
Fracture Modelling Using Seismic Based Fracture Intensity Volume, a Case Study in Middle East
Abstract
In this paper, a case study in a fractured carbonate reservoir is presented to demonstrate the approach of fracture modeling using fracture intensity vol...
A Locking Plate Designed With Cluster of Head Screws Would Be Biomechanically Superior Than Conventional Buttress Plate For The Fixation of Posteromedial Tibial Plateau Fractures: A Computational Assessment
A Locking Plate Designed With Cluster of Head Screws Would Be Biomechanically Superior Than Conventional Buttress Plate For The Fixation of Posteromedial Tibial Plateau Fractures: A Computational Assessment
Abstract
Background: Dealing with high-energy fractures of the tibial plateau remains a challenge despite advances in implants, surgical approaches, and imaging methods. Po...
Experimental Investigation on the Effects of Proppant Migration and Placement on the Conductivity in Rough Fractures
Experimental Investigation on the Effects of Proppant Migration and Placement on the Conductivity in Rough Fractures
ABSTRACT
Proppant conductivity was usually measured under static or designed proppant concentration. The ISO 13503-5 standard provides specific experimental proce...

