Javascript must be enabled to continue!
Test-retest reliability of auditory MMN measured with OPM-MEG
View through CrossRef
Abstract
In this paper, we report results from an investigation of auditory mismatch responses as measured by magnetoencephalography (MEG) based on optically pumped magnetometers (OPM). Specifically, as part of a quality control study, we examined the reliability and validity of auditory mismatch negativity (MMN) recordings, obtained with a newly installed OPM-MEG system. Based on OPM-MEG data from 30 healthy volunteers, measured twice with an established auditory MMN paradigm with frequency deviants, we examined the following questions:
First, we focused on construct validity and examined whether OPM-MEG measurements of MMN responses (in terms of event-related fields, ERFs) were qualitatively comparable to previous MMN findings from studies using EEG or MEG based on superconducting quantum interference devices (SQUIDs). In particular, we examined whether significant MMN responses measured by OPM-MEG occurred in a comparable time window and showed a similar topography as in previous EEG/MEG studies of MMN. Second, we quantified test-retest reliability of MMN amplitude and latency over two separate measurement sessions.
The results of our analyses show that MMN responses recorded with OPM-MEG are in good agreement with previously reported MMN results in terms of timing and topography. Furthermore, the comparison of group-level MMN topographies and timeseries shows excellent consistency across the two measurement sessions. Our quantitative test-retest reliability analyses at the sensor level indicate good reliability for MMN amplitude, but poor reliability for MMN latency.
Overall, our findings suggest that OPM-MEG measurements of auditory MMN (i) are comparable to results from EEG and SQUID-based MEG and (ii) show good test-retest reliability for amplitude measures at the sensor level. Notably, these results were achieved in an “out of the box” state of the OPM-MEG system, shortly after installation and without further optimisation. The reason for the insufficient reliability for MMN latency we observed is currently under investigation and represents an important target for future improvements.
Title: Test-retest reliability of auditory MMN measured with OPM-MEG
Description:
Abstract
In this paper, we report results from an investigation of auditory mismatch responses as measured by magnetoencephalography (MEG) based on optically pumped magnetometers (OPM).
Specifically, as part of a quality control study, we examined the reliability and validity of auditory mismatch negativity (MMN) recordings, obtained with a newly installed OPM-MEG system.
Based on OPM-MEG data from 30 healthy volunteers, measured twice with an established auditory MMN paradigm with frequency deviants, we examined the following questions:
First, we focused on construct validity and examined whether OPM-MEG measurements of MMN responses (in terms of event-related fields, ERFs) were qualitatively comparable to previous MMN findings from studies using EEG or MEG based on superconducting quantum interference devices (SQUIDs).
In particular, we examined whether significant MMN responses measured by OPM-MEG occurred in a comparable time window and showed a similar topography as in previous EEG/MEG studies of MMN.
Second, we quantified test-retest reliability of MMN amplitude and latency over two separate measurement sessions.
The results of our analyses show that MMN responses recorded with OPM-MEG are in good agreement with previously reported MMN results in terms of timing and topography.
Furthermore, the comparison of group-level MMN topographies and timeseries shows excellent consistency across the two measurement sessions.
Our quantitative test-retest reliability analyses at the sensor level indicate good reliability for MMN amplitude, but poor reliability for MMN latency.
Overall, our findings suggest that OPM-MEG measurements of auditory MMN (i) are comparable to results from EEG and SQUID-based MEG and (ii) show good test-retest reliability for amplitude measures at the sensor level.
Notably, these results were achieved in an “out of the box” state of the OPM-MEG system, shortly after installation and without further optimisation.
The reason for the insufficient reliability for MMN latency we observed is currently under investigation and represents an important target for future improvements.
Related Results
Mismatch Negativity in Schizophrenia – A Systematic Review and Meta-Analysis
Mismatch Negativity in Schizophrenia – A Systematic Review and Meta-Analysis
Aims:
Schizophrenia is associated with abnormalities in mismatch negativity (MMN), an event-related potential linked to sensory memory and information-processin...
Event-Wise Stability of Patient-Specific EEG-MEG Deep Learning Spike Detection in Clinical MEG
Event-Wise Stability of Patient-Specific EEG-MEG Deep Learning Spike Detection in Clinical MEG
Abstract
Objective
Computational magnetoencephalography (MEG) interictal epileptiform discharge (IED) detectors have mainly use...
Pavlovian conditioning-induced hallucinations reduce MMN amplitudes for duration but not frequency deviants
Pavlovian conditioning-induced hallucinations reduce MMN amplitudes for duration but not frequency deviants
The mismatch negativity (MMN) is an evoked potential that indexes auditory regularity violations. Since the 90’s, a reduced amplitude of this brain activity in patients with schizo...
Mismatch Negativity a Neural Marker of Auditory Spatial Adaptational Plasticity in Unilateral Hearing Loss patients
Mismatch Negativity a Neural Marker of Auditory Spatial Adaptational Plasticity in Unilateral Hearing Loss patients
Mismatch negativity, un marqueur neuronal de la plasticité spatiale auditive chez les sujets sourds unilatéraux
Cette thèse évalue les différentes fonctions d'audit...
Electrophysiological responses in relation to speech perception in children with cochlear implants
Electrophysiological responses in relation to speech perception in children with cochlear implants
Abstract
Background
Speech perception is a critical outcome of pediatric cochlear implantation, reflecting the effectiven...
Microstructural Evolution and Mechanical Performance of Two Joints of Medium-Mn Stainless Steel with Low- and High-Alloyed Steels
Microstructural Evolution and Mechanical Performance of Two Joints of Medium-Mn Stainless Steel with Low- and High-Alloyed Steels
In this work, 2 mm thick medium-Mn austenitic stainless steel (MMn–SS) plates were joined with austenitic NiCr stainless steel (NiCr–SS) and low-carbon steel (LCS) using the gas tu...
Domination of Polynomial with Application
Domination of Polynomial with Application
In this paper, .We .initiate the study of domination. polynomial , consider G=(V,E) be a simple, finite, and directed graph without. isolated. vertex .We present a study of the Ira...
Insights Into Thrombopoiesis From Infused Human Megakaryocytes Into Mice
Insights Into Thrombopoiesis From Infused Human Megakaryocytes Into Mice
Abstract
Thrombopoiesis is the process by which megakaryocytes (Megs) release platelets (Plts), but issues remain as to the detailed in vivo mechanisms underlying th...

