In pool type Fast Breeder Reactors (FBR) a passive Safety Grade Decay Heat Removal (SGDHR) system removes decay heat produced in the core when normal heat removal path through steam water system is not available. This is essential to maintain the core temperatures within limits. A Decay Heat Exchanger (DHX) picks the heat from the pool and transfers the heat to atmosphere through sodium to Air Heat Exchanger (AHX) situated at high elevation. Due to the temperature differences existent in the system density differences are generated causing a buoyant convective heat transfer. The system is completely passive as primary sodium, secondary sodium and air flows under natural convection. DHX is a sodium to sodium counter flow heat exchanger with primary sodium on shell side and secondary sodium on tube side. AHX is a cross flow heat exchanger with sodium on tube side and air flows in cross flow across the finned tubes. Capacity of a single loop of SGDHR is 8MW. Four such loops are available for the decay heat removal. It has been seen that the decay heat removal to a large extent depends on the AHX performance. AHX tested have shown reduced heat removal capacity much as 30 to 40%, essentially due to the bypassing of the finned tubes by the air. It was felt that a geometrically similar AHX be tested in sodium. Towards this a 2MW Sodium to air heat exchanger (AHX) was tested in the Steam Generator Test Facility (SGTF) constructed at Indira Gandhi Center for Atomic Research (IGCAR), Kalpakkam. The casing arrangement of the AHX was designed to minimise bypassing of air.
Title: Performance Assessment of Sodium to Air Finned Heat Exchanger for FBR
Description:
In pool type Fast Breeder Reactors (FBR) a passive Safety Grade Decay Heat Removal (SGDHR) system removes decay heat produced in the core when normal heat removal path through steam water system is not available.
This is essential to maintain the core temperatures within limits.
A Decay Heat Exchanger (DHX) picks the heat from the pool and transfers the heat to atmosphere through sodium to Air Heat Exchanger (AHX) situated at high elevation.
Due to the temperature differences existent in the system density differences are generated causing a buoyant convective heat transfer.
The system is completely passive as primary sodium, secondary sodium and air flows under natural convection.
DHX is a sodium to sodium counter flow heat exchanger with primary sodium on shell side and secondary sodium on tube side.
AHX is a cross flow heat exchanger with sodium on tube side and air flows in cross flow across the finned tubes.
Capacity of a single loop of SGDHR is 8MW.
Four such loops are available for the decay heat removal.
It has been seen that the decay heat removal to a large extent depends on the AHX performance.
AHX tested have shown reduced heat removal capacity much as 30 to 40%, essentially due to the bypassing of the finned tubes by the air.
It was felt that a geometrically similar AHX be tested in sodium.
Towards this a 2MW Sodium to air heat exchanger (AHX) was tested in the Steam Generator Test Facility (SGTF) constructed at Indira Gandhi Center for Atomic Research (IGCAR), Kalpakkam.
The casing arrangement of the AHX was designed to minimise bypassing of air.

Related Results

Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Abstract Introduction Among the most frequently used anticoagulants in hematological testing are tetra-acetic acid (EDTA), sodium citrate, and sodium heparin. However, there is a n...
Design of Cross Flow Heat Exchanger Using Performance Charts
Design of Cross Flow Heat Exchanger Using Performance Charts
The manuscript reviews the various steps involved in the design of a cross flow heat exchanger. Performance charts describing the thermal performance of the heat exchanger in terms...
ANALISIS EFEKTIVITAS LIQUID SECTION HEAT EXCHANGER DENGAN TUBE IN TUBE HEAT EXCHANGER DARI SISI APLIKATIF
ANALISIS EFEKTIVITAS LIQUID SECTION HEAT EXCHANGER DENGAN TUBE IN TUBE HEAT EXCHANGER DARI SISI APLIKATIF
Penelitian ini menjelaskan tentang aplikasidari LSHX yang lebih baik daripada jenis heat exchanger lainnyaagar penggunaan penukar kalor tipe ini lebih efektif dan dapat diaplikasik...
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Abstract This paper presents the design and cost optimization of a novel 2MWth 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that i...
Plate heat exchanger – inertia flywheel performance in loss of flow transient
Plate heat exchanger – inertia flywheel performance in loss of flow transient
Abstract One of the most versatile types of heat exchangers used is the plate heat exchanger. It has principal advantages over other heat exchangers in that plates c...
Investigation of Latent Heat Thermal Energy Storage System for AirConditioning Applications
Investigation of Latent Heat Thermal Energy Storage System for AirConditioning Applications
In this study an experimental setup was constructed to investigate the solidification process of PCM using two different types of heat exchangers: pipe heat exchanger and horizonta...
Heat Exchanger Design and Optimization
Heat Exchanger Design and Optimization
Heat exchangers are devices that transfer heat energy between fluids by utilizing heat transfer modes of conduction and convection. The shell and tube heat exchanger configuration ...
Mir-146a is required for foreign body response and giant cell formation
Mir-146a is required for foreign body response and giant cell formation
The implantation of biomaterials or medical devices often leads to the development of a foreign body response (FBR), an inflammatory condition that can lead to implant failure, whi...