Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Surgical management of proximal humerus fracture treated with locking compression plate

View through CrossRef
<p class="abstract"><strong>Background:</strong> Proximal humerus fractures accounts for about 4 to 5% of all fractures.  Treatment of unstable, displaced, and comminuted fractures of the proximal humerus remain challenging. Significant controversy continues regarding the best methods of treating displaced proximal humerus fractures. Various operative procedures are carried out, the recent trend in internal fixation has moved on to locking plates. The present study is undertaken to evaluate the functional outcome and complication of proximal humerus fractures treated by locking compression plate.</p><p class="abstract"><strong>Methods:</strong> This is a prospective study comprising of 30 patients with fractures of proximal humerus were treated by open reduction and internal fixation with locking compression plate were evaluated at Velammal  Institute Of Medical  Sciences, Madurai from the period of April 2015 to December 2016. Clinical and radiological evaluation was done. Patients will undergo open reduction internal fixation with locking compression plate for the sustained fracture under general anesthesia.<strong></strong></p><p class="abstract"><strong>Results:</strong> In our series, the majority of the patients were males, elderly aged, with RTA being the commonest mode of injury, involving 2 part, 3 part and 4 part fractures of the proximal humerus. Excellent and satisfactory results were found in 76.7% of patients with unsatisfactory results in 23.3 % according to Neer’s criteria. There were 100 % union rates and no failures.</p><p><strong>Conclusions:</strong> In conclusion locking Compression, the plate is an advantageous implant in proximal humeral fractures due to angular stability, particularly in comminuted fractures and in Osteoporotic bones in elderly patients, thus allowing early mobilization.</p>
Title: Surgical management of proximal humerus fracture treated with locking compression plate
Description:
<p class="abstract"><strong>Background:</strong> Proximal humerus fractures accounts for about 4 to 5% of all fractures.
  Treatment of unstable, displaced, and comminuted fractures of the proximal humerus remain challenging.
Significant controversy continues regarding the best methods of treating displaced proximal humerus fractures.
Various operative procedures are carried out, the recent trend in internal fixation has moved on to locking plates.
The present study is undertaken to evaluate the functional outcome and complication of proximal humerus fractures treated by locking compression plate.
</p><p class="abstract"><strong>Methods:</strong> This is a prospective study comprising of 30 patients with fractures of proximal humerus were treated by open reduction and internal fixation with locking compression plate were evaluated at Velammal  Institute Of Medical  Sciences, Madurai from the period of April 2015 to December 2016.
Clinical and radiological evaluation was done.
Patients will undergo open reduction internal fixation with locking compression plate for the sustained fracture under general anesthesia.
<strong></strong></p><p class="abstract"><strong>Results:</strong> In our series, the majority of the patients were males, elderly aged, with RTA being the commonest mode of injury, involving 2 part, 3 part and 4 part fractures of the proximal humerus.
Excellent and satisfactory results were found in 76.
7% of patients with unsatisfactory results in 23.
3 % according to Neer’s criteria.
There were 100 % union rates and no failures.
</p><p><strong>Conclusions:</strong> In conclusion locking Compression, the plate is an advantageous implant in proximal humeral fractures due to angular stability, particularly in comminuted fractures and in Osteoporotic bones in elderly patients, thus allowing early mobilization.
</p>.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Femoral Osteosynthesis in Black Capuchin Monkey (Sapajus nigritus) using Locking Plate
Femoral Osteosynthesis in Black Capuchin Monkey (Sapajus nigritus) using Locking Plate
Background: Locking bone plates for internal fixation are characterized by plates with a locknut by screwing in a threaded chamber. The increased stability associated with less vas...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference. Abstract Fractures are ubiquitous st...
Short-Term Results after Reversed Total Shoulder Arthroplasty
Short-Term Results after Reversed Total Shoulder Arthroplasty
Abstract Purpose Massive rotator cuff tear, with or without arthritis and proximal humerus fracture non-union or malunion, lead ...
The biomechanics of combined lateral and posterior plates for treating proximal humerus fractures with medial column defects
The biomechanics of combined lateral and posterior plates for treating proximal humerus fractures with medial column defects
Abstract Background. We investigated the therapeutic effects associated with the combined use of lateral and posterior plates for treating complex proximal humerus fracture...
FUNCTIONAL OUTCOME OF EXTRA-ARTICULAR DISTAL HUMERUS FRACTURE FIXATION USING A LATERAL COLUMN LOCKING COMPRESSION PLATE
FUNCTIONAL OUTCOME OF EXTRA-ARTICULAR DISTAL HUMERUS FRACTURE FIXATION USING A LATERAL COLUMN LOCKING COMPRESSION PLATE
Background: A host of different methodologies have been implemented in the management of distal humerus fractures, including conservative measures and surgical fixation with a vari...

Back to Top