Javascript must be enabled to continue!
Management of Tunica Albuginea Disruption Secondary to Malleable Penile Implant Fracture: Insights into Etiology and Surgical Approach
View through CrossRef
Abstract
Background
The tunica albuginea is a key anatomical structure supporting penile implants. Several factors can lead to anatomical penile defects, contributing to penile prosthesis malfunction.The aim is to describe the consequences of malleable penile implant fractures, their contribution to tunica albuginea defects, and management outcomes.
Results
This study included three patients with malleable penile implant malfunction secondary to device fracture. Two patients underwent PC and device replacement. One patient experienced persistent device instability despite device replacement without PC but later underwent corrective PC. The mean age at revision was 71.3 years. All patients achieved device stability and reported satisfaction after PC and device replacement, with a median follow-up of 28 months.
Conclusions
Malleable penile device fractures are extremely rare. They can cause tunica albuginea disruption and tears, compromising penile penetration and device stability. Device replacement combined with PC is an essential component of surgical management.
Title: Management of Tunica Albuginea Disruption Secondary to Malleable Penile Implant Fracture: Insights into Etiology and Surgical Approach
Description:
Abstract
Background
The tunica albuginea is a key anatomical structure supporting penile implants.
Several factors can lead to anatomical penile defects, contributing to penile prosthesis malfunction.
The aim is to describe the consequences of malleable penile implant fractures, their contribution to tunica albuginea defects, and management outcomes.
Results
This study included three patients with malleable penile implant malfunction secondary to device fracture.
Two patients underwent PC and device replacement.
One patient experienced persistent device instability despite device replacement without PC but later underwent corrective PC.
The mean age at revision was 71.
3 years.
All patients achieved device stability and reported satisfaction after PC and device replacement, with a median follow-up of 28 months.
Conclusions
Malleable penile device fractures are extremely rare.
They can cause tunica albuginea disruption and tears, compromising penile penetration and device stability.
Device replacement combined with PC is an essential component of surgical management.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Current therapeutic strategies for erectile function recovery after radical prostatectomy – literature review and meta-analysis
Current therapeutic strategies for erectile function recovery after radical prostatectomy – literature review and meta-analysis
Radical prostatectomy is the most commonly performed treatment option for localised prostate cancer. In the last decades the surgical technique has been improved and modified in or...
(24) INTRODUCING THE PENILE IMPLANT INTRAOPERATIVE MEASUREMENTS PLANNING (PIIMP) CHART: A CHART USED FOR INTRAOPERATIVELY DOCUMENTING PENILE DIMENSIONS DURING PENILE PROSTHESIS IMPLANTATION PROCEDURES.
(24) INTRODUCING THE PENILE IMPLANT INTRAOPERATIVE MEASUREMENTS PLANNING (PIIMP) CHART: A CHART USED FOR INTRAOPERATIVELY DOCUMENTING PENILE DIMENSIONS DURING PENILE PROSTHESIS IMPLANTATION PROCEDURES.
Abstract
Objectives
In this study, the Penile Implant Intraoperative Measurements Planning (PIIMP) chart was used to find out wh...
Androgen supplement did not accelerate tunica albuginea remodeling to facilitate penile growth
Androgen supplement did not accelerate tunica albuginea remodeling to facilitate penile growth
Abstract
Penile size is closely concerned and short penis contributes serious sexual dysfunction and tremendous psychological problems to couples. Androgen is essen...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...
Outcome of Malleable Penile Implant and End Stage of Erectile Dysfunction Single Centre Experience
Outcome of Malleable Penile Implant and End Stage of Erectile Dysfunction Single Centre Experience
Background: The inflatable penile prosthesis (IPP) is typically the preferred implant for Peronei’s disease (PD) and malleable penile prostheses (MPPs) have been discouraged.
...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Penile fracture following masturbation: a case report
Penile fracture following masturbation: a case report
Introduction and clinical importance:
Penile fracture is an uncommon urological emergency caused primarily by direct trauma during intercourse. Patients usually...

