Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Cervical elastography in the diagnosis of isthmic-cervical insufficiency and assessment of the efficacy of its correction

View through CrossRef
Objective. To improve the diagnosis of isthmic-cervical insufficiency (ICI) and increase the efficacy of its correction by introducing cervical elastography into the examination of pregnant patients. Patients and methods. This prospective study enrolled 180 patients with a confirmed diagnosis of ICI. Depending on the outcome of pregnancy, all patients were divided into two groups: group 1 (n = 44) included pregnant women in whom ICI correction was ineffective and who had preterm birth; group 2 (n = 136) included patients in whom ICI correction had a positive effect and who had a full-term pregnancy. ICI was diagnosed using transvaginal ultrasound with additional methods such as ultrasound elastography and examination of the composition of the vaginal biocenosis and the sensitivity of the isolated microflora to antibacterial agents. Results. The main factor affecting the efficacy of ICI correction is the baseline length of the cervix. The frequency of preterm birth with a critical cervical length <15 mm is 54.3%, and with a cervical length >20 mm, it is 13.4% (p = 0.001) (OR: 0.841; 0.779–0.908). In addition to the length of the cervix, its stiffness according to elastography is an important parameter. The “soft” type increases the risk of spontaneous preterm birth by 7.4 times (OR: 7.371; 3.083–17.619) (p = 0.001). A combined assessment of the parameters of cervical length and stiffness provides a more accurate prediction of the efficacy of ICI correction. Favorable factors for ICI correction are cervical length of 20 mm or more regardless of cervical stiffness and cervical length of 16–19 mm in combination with “medium” and “hard” types. The most unfavorable combination is a cervical length ≤15 mm with a “soft” type. Conclusion. The introduction of elastography into cervicometry improves the quality of examination and contributes to better perinatal outcomes. Mechanical correction of ICI should be performed in patients with short cervix of 20 mm. The efficacy of ICI treatment also depends on the state of the vaginal biocenosis. Key words: isthmic-cervical insufficiency, cervicometry, elastography, cerclage, obstetric pessary
Title: Cervical elastography in the diagnosis of isthmic-cervical insufficiency and assessment of the efficacy of its correction
Description:
Objective.
To improve the diagnosis of isthmic-cervical insufficiency (ICI) and increase the efficacy of its correction by introducing cervical elastography into the examination of pregnant patients.
Patients and methods.
This prospective study enrolled 180 patients with a confirmed diagnosis of ICI.
Depending on the outcome of pregnancy, all patients were divided into two groups: group 1 (n = 44) included pregnant women in whom ICI correction was ineffective and who had preterm birth; group 2 (n = 136) included patients in whom ICI correction had a positive effect and who had a full-term pregnancy.
ICI was diagnosed using transvaginal ultrasound with additional methods such as ultrasound elastography and examination of the composition of the vaginal biocenosis and the sensitivity of the isolated microflora to antibacterial agents.
Results.
The main factor affecting the efficacy of ICI correction is the baseline length of the cervix.
The frequency of preterm birth with a critical cervical length <15 mm is 54.
3%, and with a cervical length >20 mm, it is 13.
4% (p = 0.
001) (OR: 0.
841; 0.
779–0.
908).
In addition to the length of the cervix, its stiffness according to elastography is an important parameter.
The “soft” type increases the risk of spontaneous preterm birth by 7.
4 times (OR: 7.
371; 3.
083–17.
619) (p = 0.
001).
A combined assessment of the parameters of cervical length and stiffness provides a more accurate prediction of the efficacy of ICI correction.
Favorable factors for ICI correction are cervical length of 20 mm or more regardless of cervical stiffness and cervical length of 16–19 mm in combination with “medium” and “hard” types.
The most unfavorable combination is a cervical length ≤15 mm with a “soft” type.
Conclusion.
The introduction of elastography into cervicometry improves the quality of examination and contributes to better perinatal outcomes.
Mechanical correction of ICI should be performed in patients with short cervix of 20 mm.
The efficacy of ICI treatment also depends on the state of the vaginal biocenosis.
Key words: isthmic-cervical insufficiency, cervicometry, elastography, cerclage, obstetric pessary.

Related Results

Physical Principles of Elastography: A Primer for Radiologists
Physical Principles of Elastography: A Primer for Radiologists
AbstractElastography is the noninvasive method of qualitative and quantitative evaluation of strain and elastic modulus distribution in soft tissues. In simpler terms, elastography...
The Use of Ultrasound-Based Elastography Techniques in Liver Fibrosis: A Narrative Review
The Use of Ultrasound-Based Elastography Techniques in Liver Fibrosis: A Narrative Review
Background: Liver fibrosis staging plays a key role in the prognosis and management of chronic liver disease. Liver biopsy remains the reference standard for fibrosis assessment bu...
The Use of Ultrasound-Based Elastography Techniques in Liver Fibrosis: A Narrative Review
The Use of Ultrasound-Based Elastography Techniques in Liver Fibrosis: A Narrative Review
Liver fibrosis staging plays a key role in the prognosis and management of chronic liver disease. Liver biopsy remains the reference standard for fibrosis assessment but is limited...
Utility of Elastography for Differentiating Malignant and Benign Lymph Nodes During EBUS-TBNA
Utility of Elastography for Differentiating Malignant and Benign Lymph Nodes During EBUS-TBNA
Background: Ultrasound elastography noninvasively estimates tissue hardness. Studies have evaluated elastography for differentiating malignant from benign lymph nodes d...
Characterization of lesions of the Breast by using diagnostic imagining Technique: Ultrasound Elastography
Characterization of lesions of the Breast by using diagnostic imagining Technique: Ultrasound Elastography
Objective: To measure the diagnostic accuracy of Ultrasound Elastography in the differentiation of benign and malignant breast lesions from each other by simultaneously doing confi...
Relationship between cervical elastography and spontaneous onset of labor
Relationship between cervical elastography and spontaneous onset of labor
AbstractCervical elastography might be an objective method for evaluating cervical ripening during pregnancy, but its usefulness has not been fully investigated. We examined the si...
Cervical cancer screening utilization and predictors among eligible women in Ethiopia: A systematic review and meta-analysis
Cervical cancer screening utilization and predictors among eligible women in Ethiopia: A systematic review and meta-analysis
BackgroundDespite a remarkable progress in the reduction of global rate of maternal mortality, cervical cancer has been identified as the leading cause of maternal morbidity and mo...
Nodul fibromatos gigant istmic cu dezvoltare la nivelul colului uterin – caz clinic
Nodul fibromatos gigant istmic cu dezvoltare la nivelul colului uterin – caz clinic
Isthmic-cervical leiomyomas can grow very large and cause extreme discomfort. The surgical removal of these leio­myo­mas is a technical challenge, with an increased risk of operati...

Back to Top