Javascript must be enabled to continue!
New techniques to improve the power control in the double-fed induction generator wind turbine
View through CrossRef
The great interest shown today in the double-fed induction generator in wind chain prompted us to analyze the performance of the separate control of active and reactive power generated by the stator of double-fed induction generator connected to the grid. The objective of the separate control of active and reactive stator powers is to provide constant power to the power grid whatever the variation of the wind speed, and to provide reactive power to correct the power factor. In this article, we present the modeling and an integrated vector control in a double-fed induction generator wind chain, which aims to independently control the active and reactive power generated by the double-fed induction generator. Knowing that the direct control of active and reactive power delivered to the grid with conventional proportional integral controllers provides good performance in permanent diet but a variable speed wind, the measured powers hardly follow the set values. To remedy this problem, we replace the conventional proportional integral controllers with proportional integral–fuzzy controllers to ensure good performance and robustness of the control of separate powers. To justify this choice, it is necessary to evaluate and compare the separate control loop for active and reactive power with conventional proportional integral controllers than with proportional integral–fuzzy controllers under the same constraint variable speed wind. The second part treated in this article is to reduce the harmonic pollution caused by the supply of the double-fed induction generator–based inverters and controlled rectifiers, which strongly infect current line. This phenomenon can have an adverse effect on the loads connected to the grid and equipment of proximity. The insertion of a filter system in the chain is needed, except that the strain of the volume and the reflection require a high cost for a more advanced and more optimal solution. Our contribution to this part is to replace the supply of the double-fed induction generator rotor side by a matrix converter controlled by the modulation technique of the difference errors between the measured values and the desired output values (least mean square errors).
Title: New techniques to improve the power control in the double-fed induction generator wind turbine
Description:
The great interest shown today in the double-fed induction generator in wind chain prompted us to analyze the performance of the separate control of active and reactive power generated by the stator of double-fed induction generator connected to the grid.
The objective of the separate control of active and reactive stator powers is to provide constant power to the power grid whatever the variation of the wind speed, and to provide reactive power to correct the power factor.
In this article, we present the modeling and an integrated vector control in a double-fed induction generator wind chain, which aims to independently control the active and reactive power generated by the double-fed induction generator.
Knowing that the direct control of active and reactive power delivered to the grid with conventional proportional integral controllers provides good performance in permanent diet but a variable speed wind, the measured powers hardly follow the set values.
To remedy this problem, we replace the conventional proportional integral controllers with proportional integral–fuzzy controllers to ensure good performance and robustness of the control of separate powers.
To justify this choice, it is necessary to evaluate and compare the separate control loop for active and reactive power with conventional proportional integral controllers than with proportional integral–fuzzy controllers under the same constraint variable speed wind.
The second part treated in this article is to reduce the harmonic pollution caused by the supply of the double-fed induction generator–based inverters and controlled rectifiers, which strongly infect current line.
This phenomenon can have an adverse effect on the loads connected to the grid and equipment of proximity.
The insertion of a filter system in the chain is needed, except that the strain of the volume and the reflection require a high cost for a more advanced and more optimal solution.
Our contribution to this part is to replace the supply of the double-fed induction generator rotor side by a matrix converter controlled by the modulation technique of the difference errors between the measured values and the desired output values (least mean square errors).
Related Results
Contributions of flywheel systems in wind power plants
Contributions of flywheel systems in wind power plants
The stepwise replacement of conventional power plants by renewable-based ones such as wind power plants could a ect the system behaviour and planning. First, the network stability ...
Gear Based Quasi-Continuous Variable Transmission for Wind Turbines
Gear Based Quasi-Continuous Variable Transmission for Wind Turbines
Over the past decade wind turbines have been proven to be a competitive contender to produce cheap electricity. Their output electrical power went from few dozens of watts to sever...
wLEACH: Real-Time Meteorological Data Based Wind LEACH
wLEACH: Real-Time Meteorological Data Based Wind LEACH
Introduction:Nowadays, Wireless Sensor Network (WSN) plays an important role in various fields. The limited power capability of the sensor nodes in the WSN brings constraints on th...
High Efficiency Wind Turbine Using Co-Flow Jet Active Flow Control
High Efficiency Wind Turbine Using Co-Flow Jet Active Flow Control
Abstract
This paper applies Co-flow Jet (CFJ) active flow control airfoil to a NREL horizontal axis wind turbine for power output improvement. CFJ is a zero-net-m...
Stability Modeling and Analysis of Grid Connected Doubly Fed Wind Energy Generation Based on Small Signal Model
Stability Modeling and Analysis of Grid Connected Doubly Fed Wind Energy Generation Based on Small Signal Model
Stable wind power generation can ensure the quality of power transmitted by the grid. The application of large-scale grid-connected wind power systems will induce problems such as ...
Modeling of the dynamics of wind to power conversion including high wind speed behavior
Modeling of the dynamics of wind to power conversion including high wind speed behavior
AbstractThis paper proposes and validates an efficient, generic and computationally simple dynamic model for the conversion of the wind speed at hub height into the electrical powe...
Steady State Modeling and Performance Analysis of a Wind Turbine-Based Doubly Fed Induction Generator System with Rotor Control
Steady State Modeling and Performance Analysis of a Wind Turbine-Based Doubly Fed Induction Generator System with Rotor Control
The utilization of renewable energy sources aids in the economic development of a country. Among the various renewable energy sources, wind energy is more effective for electricity...
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Background:
In a wind farm, the wind speed of the downstream wind turbine will be
lower than the wind speed of the upstream wind turbine due to the influence of the wake. Therefore...

