Dosimetric comparison of gantry and horizontal fixed‐beam proton therapy treatment plans for base of skull chordoma

View through CrossRef
AbstractIntroductionAustralia's first proton beam therapy (PBT) centre will house a fixed‐beam room and two gantry rooms. As the only PBT facility in Australia for at least the short term, there is a need to efficiently allocate treatment appointments between the gantry and fixed‐beam rooms. This planning study assesses the dosimetric differences between fixed‐beam and gantry‐based treatment plans for base of skull chordoma, one of the core indications likely to be referred for PBT in Australia.MethodsRetrospective gantry‐based and fixed‐beam treatment plans were generated for five patients with base of skull chordoma. Fixed‐beam plans were generated with a conventional horizontal patient positioning system. Robust intensity modulated proton therapy (IMPT) optimisation and evaluation techniques were used for both delivery systems. Plans were designed to maximise target coverage while adhering to maximum dose constraints to neighbouring critical organs at risk.ResultsRobust target coverage and integral dose were found to be approximately equivalent for the gantry‐based and fixed‐beam plans. Doses to specific organs at risk could be reduced with the gantry‐based geometry; however, the gantry‐based plans did not exhibit a general decrease in doses to organs at risk.ConclusionA fixed‐beam treatment plan was found to be non‐inferior to a gantry‐based treatment plan for all base of skull patients included in the current study.
Title: Dosimetric comparison of gantry and horizontal fixed‐beam proton therapy treatment plans for base of skull chordoma
Description:
AbstractIntroductionAustralia's first proton beam therapy (PBT) centre will house a fixed‐beam room and two gantry rooms.
As the only PBT facility in Australia for at least the short term, there is a need to efficiently allocate treatment appointments between the gantry and fixed‐beam rooms.
This planning study assesses the dosimetric differences between fixed‐beam and gantry‐based treatment plans for base of skull chordoma, one of the core indications likely to be referred for PBT in Australia.
MethodsRetrospective gantry‐based and fixed‐beam treatment plans were generated for five patients with base of skull chordoma.
Fixed‐beam plans were generated with a conventional horizontal patient positioning system.
Robust intensity modulated proton therapy (IMPT) optimisation and evaluation techniques were used for both delivery systems.
Plans were designed to maximise target coverage while adhering to maximum dose constraints to neighbouring critical organs at risk.
ResultsRobust target coverage and integral dose were found to be approximately equivalent for the gantry‐based and fixed‐beam plans.
Doses to specific organs at risk could be reduced with the gantry‐based geometry; however, the gantry‐based plans did not exhibit a general decrease in doses to organs at risk.
ConclusionA fixed‐beam treatment plan was found to be non‐inferior to a gantry‐based treatment plan for all base of skull patients included in the current study.

Related Results

Rotatorlike gantry optics
Rotatorlike gantry optics
Rotating gantries are commonly used in ion-therapy facilities to assist and support optimizing the dose distribution delivered to the patient. They are installed at the end of the ...
IMAT‐SIM: A new method for the clinical dosimetry of intensity‐modulated arc therapy (IMAT)
IMAT‐SIM: A new method for the clinical dosimetry of intensity‐modulated arc therapy (IMAT)
Dynamic‐gantry multi‐leaf collimator (MLC)‐based, intensity‐modulated radiotherapy (IMAT) has been proposed as an alternative to tomotherapy. In contrast to fixed‐gantry, MLC‐based...
Matrix Analysis and Design Study of Rotatorlike Gantry Optics
Matrix Analysis and Design Study of Rotatorlike Gantry Optics
Modern ion-therapy facilities are usually equipped with rotating gantries to achieve higher dose-conformity to the tumor. The gantry is the terminating part of a beam transfer-line...
Data from Expression and Therapeutic Potential of SOX9 in Chordoma
Data from Expression and Therapeutic Potential of SOX9 in Chordoma
<div>Abstract<p><b>Purpose:</b> Conventional chemotherapeutic agents are ineffective in the treatment of chordoma. We investigated the functional roles and ...
MO‐SAM‐BRB‐02: Proton Physics and Technology
MO‐SAM‐BRB‐02: Proton Physics and Technology
The dose localization advantages of proton beams derive primarily from the Bragg peak in the proton stopping distribution. Therefore, the potential clinical gains expected form pro...
Developing the advanced dosimetry of linac beam radiotherapy
Developing the advanced dosimetry of linac beam radiotherapy
<p dir="ltr">Photon beams remains the most widely used modality for radiotherapy of cancer worldwide. Continued technological development has enabled increasingly conformal t...
Developing the advanced dosimetry of linac beam radiotherapy
Developing the advanced dosimetry of linac beam radiotherapy
<p dir="ltr">Photon beams remains the most widely used modality for radiotherapy of cancer worldwide. Continued technological development has enabled increasingly conformal t...