Synchrotron X-ray imaging for characterizing chrysotile asbestos
View through CrossRef
<p>Over the last decades, rocks containing Naturally Occurring Asbestos (NOA) have been widely studied by many authors with the aim of determining the potential health risks to exposed neighboring populations. It is difficult to accurately characterize the asbestos fibres contained within the rocks as conventional techniques are not effective and have drawbacks associated with the disturbance of the sample under study. Indeed, the size and geometric shape ratios of asbestos chrysotile fibres can be subjected to change, thus leading to the misevaluation of asbestiform fibre findings. In this frame, our study aims to determine the characteristics of the veins that form in serpentinite (i.e. shape) and their infill (i.e. size of fibres), without grinding and/or particle size reduction.</p><p>To obtain this ambitious goal, X-ray synchrotron microtomography (SR-&#956;CT) supplemented with polarized light microscope (PLM), scanning electron microscopy analysis combined with energy dispersive spectrometry (SEM/EDS), electron probe micro-analysis (EPMA) were used for identifying asbestos fibres in a mineral matrix. In the specific case, we analyzed a representative set of veins and fibrous chrysotile that fills the veins, taken from massive serpentinite outcrops (Southern-Italy; Bloise and Miriello, 2008). The non-destructive SR-&#956;CT technique allowed to identify respirable chrysotile fibres (regulated asbestos) within the serpentinite matrix and to reconstruct the 3D structures of infill chrysotile asbestos fibres as well as other phase, whose structures were not resolvable with PLM, SEM or EPMA. Moreover, due to differences in chemical composition between veins and matrix, the obtained data enabled to evaluate the vein shapes present in the massive serpentinite matrix. In particular, iron and aluminum distribution variations between veins and matrix induce different radiation absorption patterns, thus permitting a detailed image-based 3D geometric reconstruction (Bloise et al., 2019). The results proved that SR-&#956;CT is a valuable and promising technique for analyzing asbestos chrysotile that fills the veins within massive serpentinite. The 3D images of veins may help to identify NOA contained within serpentinite rocks.</p><p>References:</p><p>Bloise, A., Miriello, D., 2018. Multi-analytical approach for identifying asbestos minerals in situ. Geosci. 8 (4), 133. https://doi.org/10.3390/geosciences8040133.</p><p>Bloise, A., Ricchiuti, C., Lanzafame, G., Punturo, R., 2019. X-ray synchrotron microtomography: a new technique for characterizing chrysotile asbestos, Sci. Total Environ. https://doi.org/10.1016/j.scitotenv.2019.135675</p>
Title: Synchrotron X-ray imaging for characterizing chrysotile asbestos
Description:
<p>Over the last decades, rocks containing Naturally Occurring Asbestos (NOA) have been widely studied by many authors with the aim of determining the potential health risks to exposed neighboring populations.
It is difficult to accurately characterize the asbestos fibres contained within the rocks as conventional techniques are not effective and have drawbacks associated with the disturbance of the sample under study.
Indeed, the size and geometric shape ratios of asbestos chrysotile fibres can be subjected to change, thus leading to the misevaluation of asbestiform fibre findings.
In this frame, our study aims to determine the characteristics of the veins that form in serpentinite (i.
e.
shape) and their infill (i.
e.
size of fibres), without grinding and/or particle size reduction.
</p><p>To obtain this ambitious goal, X-ray synchrotron microtomography (SR-&#956;CT) supplemented with polarized light microscope (PLM), scanning electron microscopy analysis combined with energy dispersive spectrometry (SEM/EDS), electron probe micro-analysis (EPMA) were used for identifying asbestos fibres in a mineral matrix.
In the specific case, we analyzed a representative set of veins and fibrous chrysotile that fills the veins, taken from massive serpentinite outcrops (Southern-Italy; Bloise and Miriello, 2008).
The non-destructive SR-&#956;CT technique allowed to identify respirable chrysotile fibres (regulated asbestos) within the serpentinite matrix and to reconstruct the 3D structures of infill chrysotile asbestos fibres as well as other phase, whose structures were not resolvable with PLM, SEM or EPMA.
Moreover, due to differences in chemical composition between veins and matrix, the obtained data enabled to evaluate the vein shapes present in the massive serpentinite matrix.
In particular, iron and aluminum distribution variations between veins and matrix induce different radiation absorption patterns, thus permitting a detailed image-based 3D geometric reconstruction (Bloise et al.
, 2019).
The results proved that SR-&#956;CT is a valuable and promising technique for analyzing asbestos chrysotile that fills the veins within massive serpentinite.
The 3D images of veins may help to identify NOA contained within serpentinite rocks.
</p><p>References:</p><p>Bloise, A.
, Miriello, D.
, 2018.
Multi-analytical approach for identifying asbestos minerals in situ.
Geosci.
8 (4), 133.
https://doi.
org/10.
3390/geosciences8040133.
</p><p>Bloise, A.
, Ricchiuti, C.
, Lanzafame, G.
, Punturo, R.
, 2019.
X-ray synchrotron microtomography: a new technique for characterizing chrysotile asbestos, Sci.
Total Environ.
https://doi.
org/10.
1016/j.
scitotenv.
2019.
135675</p>.
Related Results
Case Report: Forensic Chemistry Analysis in Asbestos Litigation
Case Report: Forensic Chemistry Analysis in Asbestos Litigation
Chrysotile asbestos, a naturally occurring fibrous silicate mineral, is extensively used in various industries due to its advantageous properties, including low cost, thermal insul...
Brucite, a natural raw material used worldwide, can be contaminated by asbestos
Brucite, a natural raw material used worldwide, can be contaminated by asbestos
<p>Brucite is a hydroxide mineral [Mg(OH)<sub>2</sub>] with a hexagonal structure (space group <em>P</em>3&...
Use of the ASTM Inter-Laboratory Studies (ILS) Program in Developing Precision Data for ASTM D5755 – Asbestos in Dust by Microvacuum Sampling
Use of the ASTM Inter-Laboratory Studies (ILS) Program in Developing Precision Data for ASTM D5755 – Asbestos in Dust by Microvacuum Sampling
Abstract
ASTM Standard D5755 “Standard Test Method for Microvacuum Sampling and Indirect Analysis of Dust by Transmission Electron Microscopy (TEM) for Asbestos Stru...
The Use of Synchrotron Radiation in Virology
The Use of Synchrotron Radiation in Virology
Introduction: The demand for new rapid methods for development of medicines for health care is becoming more relevant. Detailed knowledge of the spatial structure of viral proteins...
Mesothelioma in a community in the north of England.
Mesothelioma in a community in the north of England.
OBJECTIVES: To find the numbers of mesotheliomas in Calderdale over the period 1966-94 and determine their relation to asbestos exposure, pathology, and mineral fibre burden within...
Malignant Mesothelioma of the Pleura in Nonagenarian Patients
Malignant Mesothelioma of the Pleura in Nonagenarian Patients
Aims and background Malignant mesothelioma developing at very old ages is a rare event. The reasons for such late development were investigated. Methods A series of 811 malignant m...
Asbestos and Intrahepatic Cholangiocarcinoma
Asbestos and Intrahepatic Cholangiocarcinoma
The link between asbestos exposure and the onset of thoracic malignancies is well established. However epidemiological studies have provided evidences that asbestos may be also inv...
The Synchrotron Radiation for Steel Research
The Synchrotron Radiation for Steel Research
The synchrotron X-ray radiation is a great tool in materials characterization with several advantageous features. The high intensity allows clear interaction signals and high energ...