Javascript must be enabled to continue!
Design of a new 3D‐printed joint plug
View through CrossRef
AbstractThis paper introduces a kit of parts as a novel three‐dimensional (3D)–printed joint plug, in which each of the parts function cooperatively to treat cartilage damage in joints of the human body (e.g., hips, wrists, elbow, knee, and ankle). Three required and one optional parts are involved in this plug. The first part is a 3D‐printed hard scaffold (bone portion) to accommodate bone cells, and the second is a 3D‐printed soft scaffold (cartilage portion) overlying the bone portion to accommodate chondrocytes. The third part of joint plug is a permeable membrane, termed film, to cover the entire plug to provide coordinated sliding of the joint during the regeneration of the cartilage. Film is also responsible for retention of the chondrocytes while allowing nutrients to diffuse through the membrane. The plug may further include a fourth part, called barrier, which is a membrane to assist the bone portion in avoiding the loss of chondrocytes from the cartilage portion beyond the barrier. Various engagement means among the parts of the plug are assumed, which are discussed in this paper. Moreover, the detailed design criteria and selection of suitable materials for different parts are elaborated. The 3D‐printing practice allows the plug to be personalized and fabricated to fit the shape/size of the target joint and the injured section. Also discussed are the configuration options of the plug to be surgically implanted in a joint. Although the focus of this paper is on the design, a brief overview of a prototype is presented.
Title: Design of a new 3D‐printed joint plug
Description:
AbstractThis paper introduces a kit of parts as a novel three‐dimensional (3D)–printed joint plug, in which each of the parts function cooperatively to treat cartilage damage in joints of the human body (e.
g.
, hips, wrists, elbow, knee, and ankle).
Three required and one optional parts are involved in this plug.
The first part is a 3D‐printed hard scaffold (bone portion) to accommodate bone cells, and the second is a 3D‐printed soft scaffold (cartilage portion) overlying the bone portion to accommodate chondrocytes.
The third part of joint plug is a permeable membrane, termed film, to cover the entire plug to provide coordinated sliding of the joint during the regeneration of the cartilage.
Film is also responsible for retention of the chondrocytes while allowing nutrients to diffuse through the membrane.
The plug may further include a fourth part, called barrier, which is a membrane to assist the bone portion in avoiding the loss of chondrocytes from the cartilage portion beyond the barrier.
Various engagement means among the parts of the plug are assumed, which are discussed in this paper.
Moreover, the detailed design criteria and selection of suitable materials for different parts are elaborated.
The 3D‐printing practice allows the plug to be personalized and fabricated to fit the shape/size of the target joint and the injured section.
Also discussed are the configuration options of the plug to be surgically implanted in a joint.
Although the focus of this paper is on the design, a brief overview of a prototype is presented.
Related Results
Improved Method of Setting Successful Cement Plugs
Improved Method of Setting Successful Cement Plugs
Summary
Setting openhole cement plugs has historically been a difficult task. Often, several attempts are required to set a cement plug before one is obtained tha...
Clinical efficacy of OASIS Preloaded Punctal Plug in Comparison to Smart Plug Punctal Plug in Aqueous-Deficient Dry Eye Disease
Clinical efficacy of OASIS Preloaded Punctal Plug in Comparison to Smart Plug Punctal Plug in Aqueous-Deficient Dry Eye Disease
Abstract
BackgroundAt present, there are few clinical studies comparing OASIS preloaded punctal plug and Smart Plug punctal plug for dry eye. This study intends to evaluate...
The Effect of Sand Plug at the Gas Well Bottom-hole on its Productive Characteristics
The Effect of Sand Plug at the Gas Well Bottom-hole on its Productive Characteristics
The reasons that lead to the destruction of the bottomhole zone during the operation of wells with unstable reservoirs are considered. The negative effects of the sand carry-over f...
New Experimental Equipment for Hydrate Dissociation Studies
New Experimental Equipment for Hydrate Dissociation Studies
Abstract
A new experimental set up dedicated to the hydrate dissociation studies is presented. In this new equipment, hydrate dissociation can be achieved by depr...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract
Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
High Temperature Dissolvable Materials Development for High Temperature Dissolvable Plug Applications
High Temperature Dissolvable Materials Development for High Temperature Dissolvable Plug Applications
Abstract
Dissolvable tools have been used more in unconventional oil and gas operations in recent years. Currently, more and more wells in Southwest of China quires ...
SPARK PLUG PROBLEMS IN AUTOMOTIVE SERVICE
SPARK PLUG PROBLEMS IN AUTOMOTIVE SERVICE
<div class="htmlview paragraph">The selection of a spark plug of the proper heat range for automotive service is becoming increasingly difficult in spite of the many improvem...

