Audit Energi dan Rekomendasi Penghematan Energi Listrik di Gedung Rumah Sakit
View through CrossRef
The actions for electricity consumption more efficiently is reducing the amount of electricity consumption of renewable and non renewable energy for human living sustainability or we can called energy conservation. Energy audit purposed to the energy utilization evaluation progress, is still infrequently applied in Indonesia, especially in huge building. The analyzing result of A building in the Dr. Radjiman Wediodiningrat Asylum, the first value audit of Energy Use Intensity (EUI) is 21,944 kwh/m2/year it was include the criteria of efficient. This EUI value is below EUI research that was issued by ASEAN-USAID in 1992 and the EUI value average of hospital in Korea, while detailed audit obtained energy value of EUI is 23,213 kWh/m2/year is included to the criteria of efficient. The THDi value in electricity system is IR= 33,2%, IS=24,48%, IT= 34,85% and IN=122,96%, the THDi value is not complied with IEEE 519-2014 permission which is the value is ISC/IL> 1000 has restraint value by 20%. Whereas the THDv value in electricity system is VR-S= 2,04%, VS-T= 2,11%, VT-R= 1,97%, VR-N= 3,83%, VS-N= 3,69%, VT-N= 3,73% and VL-L= 2,04% and VL-N= 3,75%, the value of THDv is complied the permissiod by IEEE 519-2014 with Voltage system of identification by 0,4 kV, therefore the limit value of THDV which permitted is 8%.
Politeknik Negeri Malang
Title: Audit Energi dan Rekomendasi Penghematan Energi Listrik di Gedung Rumah Sakit
Description:
The actions for electricity consumption more efficiently is reducing the amount of electricity consumption of renewable and non renewable energy for human living sustainability or we can called energy conservation.
Energy audit purposed to the energy utilization evaluation progress, is still infrequently applied in Indonesia, especially in huge building.
The analyzing result of A building in the Dr.
Radjiman Wediodiningrat Asylum, the first value audit of Energy Use Intensity (EUI) is 21,944 kwh/m2/year it was include the criteria of efficient.
This EUI value is below EUI research that was issued by ASEAN-USAID in 1992 and the EUI value average of hospital in Korea, while detailed audit obtained energy value of EUI is 23,213 kWh/m2/year is included to the criteria of efficient.
The THDi value in electricity system is IR= 33,2%, IS=24,48%, IT= 34,85% and IN=122,96%, the THDi value is not complied with IEEE 519-2014 permission which is the value is ISC/IL> 1000 has restraint value by 20%.
Whereas the THDv value in electricity system is VR-S= 2,04%, VS-T= 2,11%, VT-R= 1,97%, VR-N= 3,83%, VS-N= 3,69%, VT-N= 3,73% and VL-L= 2,04% and VL-N= 3,75%, the value of THDv is complied the permissiod by IEEE 519-2014 with Voltage system of identification by 0,4 kV, therefore the limit value of THDV which permitted is 8%.
Related Results
Penghematan Listrik Rumah Tangga dalam Menunjang Kestabilan Energi Nasional dan Kelestarian Lingkungan
Penghematan Listrik Rumah Tangga dalam Menunjang Kestabilan Energi Nasional dan Kelestarian Lingkungan
ABSTRACTThe government efforts to maintain national energy stability program through the increase energy supply and saving must be supported by all levels of society. Several energ...
Hubungan Kualitas Audit, Komite Audit, dan Dewan Pengawas Syariah terhadap Kinerja Bank Umum Syariah di Indonesia
Hubungan Kualitas Audit, Komite Audit, dan Dewan Pengawas Syariah terhadap Kinerja Bank Umum Syariah di Indonesia
ABSTRAK
Penelitian ini ditujukan untuk mengetahui hubungan kualitas audit, komite audit, dan Dewan Pengawas Syariah (DPS) terhadap kinerja Bank Umum Syariah di Indonesia pada tahun...
Paper K-9 Pelaporan Hasil Audit dan Tindak Lanjut Audit Internal
Paper K-9 Pelaporan Hasil Audit dan Tindak Lanjut Audit Internal
Pelaporan hasil audit merupakan komponen utama dalam komunikasi dari audit internal tentang hasil audit. Untuk mengkomunikasikan hasil audit diperlukan susunan laporan, dimana hasi...
PELUANG PENGHEMATAN ENERGI PADA GEDUNG FAKULTAS TEKNIK UNIVERSITAS MUHAMMADIYAH PALEMBANG
PELUANG PENGHEMATAN ENERGI PADA GEDUNG FAKULTAS TEKNIK UNIVERSITAS MUHAMMADIYAH PALEMBANG
Gedung Fakultas Teknik Universitas Muhammadiyah Palembang merupakan salah satu sarana proses belajar mengajar yang terbagi menjadi dua gedung, yaitu gedung A dan gedung B. Menyedia...
ANALISIS PELUANG EFISIENSI MELALUI KONSERVASI ENERGI PADA SISTEM TATA UDARA DI GEDUNG RUMAH SAKIT UMUM NURHAYATI GARUT
ANALISIS PELUANG EFISIENSI MELALUI KONSERVASI ENERGI PADA SISTEM TATA UDARA DI GEDUNG RUMAH SAKIT UMUM NURHAYATI GARUT
Penelitian membahas tentang konservasi energi pada sistem tata udara untuk meningkatkan efisiensi penggunaan energi listrik pada gedung karena penggunaan energi listrik pada gedung...
PERBANDINGAN KELAYAKAN FINANSIAL GEDUNG GREEN BUILDING DAN NON- GREEN BUILDING MENGGUNAKAN METODE MONTE CARLO
PERBANDINGAN KELAYAKAN FINANSIAL GEDUNG GREEN BUILDING DAN NON- GREEN BUILDING MENGGUNAKAN METODE MONTE CARLO
Since 2011, Indonesia has been committed to reducing greenhouse gas emissions, one of which is by implementing green buildings in office buildings. The aim of implementing green bu...
Dimensi Kesadaran dan Perilaku Pekerja Terhadap Penghematan Energi di Kantor
Dimensi Kesadaran dan Perilaku Pekerja Terhadap Penghematan Energi di Kantor
Penelitian mengenai penghematan energi selama ini masih terfokus kepada penghematan yang dilakukan pada tingkat rumah tangga. Namun, faktanya adalah, bangunan komersil, terutama ba...
PEMASANGAN PEMBANGKIT TENAGA SURYA UNTUK INSTALASI RUMAH (SOLAR HOME)
PEMASANGAN PEMBANGKIT TENAGA SURYA UNTUK INSTALASI RUMAH (SOLAR HOME)
Latar Belakang : Latar belakang penelitian ini adalah Pembangkit Listrik Tenaga Surya atau disingkat PLTS, sistem ini mampu mengubah energi matahari menjadi energi listrik, ia terg...