Abstract Background Regional citrate anticoagulation (RCA) is the most widespread technique which allows to perform extracorporeal treatments, avoiding the complications of systemic anticoagulation. Due to limited citrate clearance, RCA may be applied only to low extracorporeal blood flows (i.e., BF < 200 ml/min). In this proof of concept study, we developed an innovative RCA technique based on Ion Exchange Resin (i-ER) technology capable of regionally anticoagulating BF up to 500 mL/min. Methods Six healthy swine (41.0 ± 3.1 kg) were sedated, mechanically ventilated, and connected to a prototype extracorporeal circuit for continuous renal replacement therapy featuring a citrate-removal stage based on absorbent materials and replacement fluids. Blood flow was 500 ml/min. Sodium citrate was continuously infused at the circuit inlet (5 mmol/L). Heparin was continuously infused. Citrate concentration and Kaolin Heparinase thromboelastography (KH-TEG) were measured on arterial blood, extracorporeal blood downstream the citrate infusion port, and downstream the citrate-removal stage. Samples were collected at baseline, 2, 8, 15, 30, 45, 60, 90, and 120 min for citrate and at baseline, 2, 30, 60, and 120 min for KH–TEG. Calcium chloride was infused to maintain systemic ionized calcium within the physiological range. The experiment lasted 2 h. Results During the whole experiment, KH–TEG in the artery showed normal coagulation: reaction time (R) was 8.30[6.80–10.10] min, with Maximum Amplitude (MA) of 71.70[67.90–77.00] mm, while in the extracorporeal circuit, KH–TEG showed no sign of clot formation R > 60 min, MA = 0 mm. Citrate concentrations in blood samples were stable within 30 min, then slowly increased. The efficacy of the citrate-removal dropped from 93.8 ± 3.4% to 48.3 ± 1.5% at the beginning (2 min) and at the end (2 h), respectively (p < 0.001), due to loss of efficiency of the iERs. Conclusions This study demonstrates that iER-based RCA is a feasible and effective technique for regional anticoagulation of extracorporeal blood flow up to 500 mL/min for 60 min without significant complications.
Title: Citrate regional anticoagulation of 500 ml/min of extracorporeal blood flow: an experimental study
Description:
Abstract Background Regional citrate anticoagulation (RCA) is the most widespread technique which allows to perform extracorporeal treatments, avoiding the complications of systemic anticoagulation.
Due to limited citrate clearance, RCA may be applied only to low extracorporeal blood flows (i.
e.
, BF < 200 ml/min).
In this proof of concept study, we developed an innovative RCA technique based on Ion Exchange Resin (i-ER) technology capable of regionally anticoagulating BF up to 500 mL/min.
Methods Six healthy swine (41.
0 ± 3.
1 kg) were sedated, mechanically ventilated, and connected to a prototype extracorporeal circuit for continuous renal replacement therapy featuring a citrate-removal stage based on absorbent materials and replacement fluids.
Blood flow was 500 ml/min.
Sodium citrate was continuously infused at the circuit inlet (5 mmol/L).
Heparin was continuously infused.
Citrate concentration and Kaolin Heparinase thromboelastography (KH-TEG) were measured on arterial blood, extracorporeal blood downstream the citrate infusion port, and downstream the citrate-removal stage.
Samples were collected at baseline, 2, 8, 15, 30, 45, 60, 90, and 120 min for citrate and at baseline, 2, 30, 60, and 120 min for KH–TEG.
Calcium chloride was infused to maintain systemic ionized calcium within the physiological range.
The experiment lasted 2 h.
Results During the whole experiment, KH–TEG in the artery showed normal coagulation: reaction time (R) was 8.
30[6.
80–10.
10] min, with Maximum Amplitude (MA) of 71.
70[67.
90–77.
00] mm, while in the extracorporeal circuit, KH–TEG showed no sign of clot formation R > 60 min, MA = 0 mm.
Citrate concentrations in blood samples were stable within 30 min, then slowly increased.
The efficacy of the citrate-removal dropped from 93.
8 ± 3.
4% to 48.
3 ± 1.
5% at the beginning (2 min) and at the end (2 h), respectively (p < 0.
001), due to loss of efficiency of the iERs.
Conclusions This study demonstrates that iER-based RCA is a feasible and effective technique for regional anticoagulation of extracorporeal blood flow up to 500 mL/min for 60 min without significant complications.

Related Results

Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Abstract Introduction Among the most frequently used anticoagulants in hematological testing are tetra-acetic acid (EDTA), sodium citrate, and sodium heparin. However, there is a n...
JIT 2023 - Jornadas de Jóvenes Investigadores Tecnológicos
JIT 2023 - Jornadas de Jóvenes Investigadores Tecnológicos
Es un honor presentar este libro que compila los trabajos de investigación y desarrollo presentados en las Jornadas de Jóvenes Investigadores Tecnológicos (JIT) 2023. Este evento s...
Citrate Blood a Century of Artifact.
Citrate Blood a Century of Artifact.
Abstract Sodium citrate has been used as an anticoagulant to prepare blood and fractions for over 100 years. Its use is sufficiently common that many investigators d...
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
BackgroundA clinical dilemma exists in patients with CKD, ESKD, and after kidney transplantation, as they face concurrent risks of both thromboembolic and hemorrhagic complications...
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
Abstract Introduction In patients with 70% to 99% diameter carotid artery stenosis cerebral blood flow reserve may be protectiv...

Back to Top